CoChat

Fluorescent Bacterial Magnetic Nanoparticles as Bimodal Contrast Agents

Lisy, Marcus-Ren??, Hartung, Annegret, Lang, Claus, Sch??ler, Dirk, Richter, Walter, Reichenbach, J??rgen R., Kaiser, Werner A., Hilger, Ingrid · 2007 · Investigative Radiology
Cited by 79

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: The purpose of this study was to assess whether fluorochrome-coupled bacterial magnetic nanoparticles can be used as bimodal contrast agent for both magnetic resonance imaging (MRI) and near-infrared fluorescence optical (NIRF) imaging of cultured macrophages. MATERIALS AND METHODS: Bacterial magnetic nanoparticles (magnetosomes, particle diameter: 42 nm) were harvested from Magnetospirillum gryphiswaldense and characterized by using MRI. After covalent coupling to the fluorescent dye DY-676 (lambdaabs./lambdaem.= 676 nm/701 nm, Dyomics, Jena, Germany), the fluorescent magnetosomes were analyzed by fluorescence-activated cell sorting. Subsequently, murine macrophages J774 were incubated with the bimodal contrast agent (3 hours) and examined by a whole-body near infrared small animal imaging system as well as by using a 1.5 T clinical MR system. Moreover, labeled cells were characterized using confocal laser scanning microscopy (CLSM) and ultrathin section transmission electron microscopy. RESULTS: Characterization of the nanoparticles by MRI revealed R1 and R2 relaxivities of 3.2 mMs and 526 mMs, respectively. Fluorochrome-coupled magnetosomes exhibited increased fluorescence intensities at wavelengths >670 nm. Macrophages that were incubated with the contrast agent showed a significant fluorescence emission in the near infrared range as imaged with a whole body NIR imaging system, FACS analysis and CLSM. Moreover, CLSM data showed the greatest fluorescence intensities within intracellular compartments and colocalized with the magnetosomes. With MRI, both T1 and T2 relaxation times were substantially shortened at concentrations greater than 600 cells/microL. DISCUSSION AND CONCLUSION: Macrophages could be labeled with fluorescent magnetosomes, and they were successfully imaged using both a 1.5 T MR scanner as well as with NIRF optical methods. The use of this bimodal contrast agent for diagnostic purposes may benefit from the excellent spatial resolution of the MRI and the high sensitivity of the fluorescence imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.rli.0000255832.44443.e7

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 79

Metadata

Authors
Lisy, M.-R., Hartung, A., Lang, C., Sch??ler, D., Richter, W., Reichenbach, J. R., Kaiser, W. A., & Hilger, I.
Venue
Investigative Radiology
Published
2007-04
Volume
42
Issue
4
Pages
235-241
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2089777050
Cited by
79
References
1
FWCI
4.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluorescent Bacterial Magnetic Nanoparticles as Bimodal Contrast Agents. https://app.cochat.ai/papers/10.1097/01.rli.0000255832.44443.e7
The paper
Lisy, M.-R., Hartung, A., Lang, C., Sch??ler, D., Richter, W., Reichenbach, J. R., Kaiser, W. A., & Hilger, I. (2007). Fluorescent Bacterial Magnetic Nanoparticles as Bimodal Contrast Agents. Investigative Radiology. https://doi.org/10.1097/01.rli.0000255832.44443.e7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.