Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 232

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

SERUM S-100B CONCENTRATION PROVIDES ADDITIONAL INFORMATION FOT THE INDICATION OF COMPUTED TOMOGRAPHY IN PATIENTS AFTER MINOR HEAD INJURY: A PROSPECTIVE MULTICENTER STUDY

Biberthaler, Peter, Linsenmeier, Ulrich, Pfeifer, Klaus-Juergen, Kroetz, Michael, Mussack, Thomas, Kanz, Karl-Georg, Hoecherl, Eduard F.J., Jonas, Felix, Marzi, Ingo, Leucht, Phillip, Jochum, Marianne, Mutschler, Wolf · 2006 · Shock

Abstract

Ninety percent of patients with minor head injury (MHI) who have cranial computed tomography (CCT) under the present clinical decision rules have normal scans. Serum concentrations of the astroglial protein S-100B were recently found to provide useful information, but these studies were too small to provide a statistically safe basis for changing the present rule. We have investigated whether S-100B concentrations in patients with MHI can provide additional information to improve indication of the need for an initial CCT scan. One thousand three hundred nine patients with MHI were enrolled in this prospective, multicenter study. All had a CCT scan to confirm diagnosis in accordance with the present clinical decision rules. S-100B was measured in serum samples obtained upon admission. Data were analyzed using contingency table and receiver operating characteristic curve and compared with those for healthy donors (n = 540) and with those for patients with moderate to severe head injury (n = 55). Of the 1309 patients studied, 93 exhibited trauma-relevant intracerebral lesions on the CCT scan (CCT+). With a cutoff limit of 0.10-microg/L S-100B (95th percentile of values in healthy volunteers), CCT+ patients were identified with a sensitivity level of 99% (95% confidence interval, 96% - 100%) and a specificity level of 30% (95% confidence interval, 29% - 31%). Adding the measurement of S-100B concentration to the clinical decision rules for a CCT scan in patients with MHI could allow a 30% reduction in scans. A prospective study of the clinical value of S-100B measurement in such patients is now under way.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.shk.0000209534.61058.35

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Biberthaler, P., Linsenmeier, U., Pfeifer, K.-J., Kroetz, M., Mussack, T., Kanz, K.-G., Hoecherl, E. F. J., Jonas, F., Marzi, I., Leucht, P., Jochum, M., & Mutschler, W.
Venue
Shock
Published
2006-05
Volume
25
Issue
5
Pages
446-453
ISSN
1073-2322 (ISSN-L)
OpenAlex
W2063267714
Cited by
232
References
1
FWCI
6.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SERUM S-100B CONCENTRATION PROVIDES ADDITIONAL INFORMATION FOT THE INDICATION OF COMPUTED TOMOGRAPHY IN PATIENTS AFTER MINOR HEAD INJURY: A PROSPECTIVE MULTICENTER STUDY. https://app.cochat.ai/papers/10.1097/01.shk.0000209534.61058.35
The paper
Biberthaler, P., Linsenmeier, U., Pfeifer, K.-J., Kroetz, M., Mussack, T., Kanz, K.-G., Hoecherl, E. F. J., Jonas, F., Marzi, I., Leucht, P., Jochum, M., & Mutschler, W. (2006). SERUM S-100B CONCENTRATION PROVIDES ADDITIONAL INFORMATION FOT THE INDICATION OF COMPUTED TOMOGRAPHY IN PATIENTS AFTER MINOR HEAD INJURY: A PROSPECTIVE MULTICENTER STUDY. Shock. https://doi.org/10.1097/01.shk.0000209534.61058.35

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.