Evidence-Based Compression: Prevention of Stasis and Deep Vein Thrombosis
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
In Brief Objective: To summarize the currently published scientific evidence for the venous flow effects of mechanical devices, particularly intermittent pneumatic compression, and the relation to prevention of deep vein thrombosis (DVT). Summary Background Data: While intermittent pneumatic compression is an established method of DVT prophylaxis, the variety of systems that are available can use very different compression techniques and sequences. In order for appropriate choices to be made to provide the optimum protection for patients, the general performance of systems, and physiological effects of particular properties, must be analyzed objectively. Methods: Medline was searched from 1970 to 2002, and all relevant papers were searched for further appropriate references. Papers were selected for inclusion when they addressed specifically the questions posed in this review. Results: All the major types of intermittent compression systems are successful in emptying deep veins of the lower limb and preventing stasis in a variety of subject groups. Compression stockings appear to function more by preventing distension of veins. Rapid inflation, high pressures, and graded sequential intermittent compression systems will have particular augmentation profiles, but there is no evidence that such features improve the prophylactic ability of the system. Conclusions: The most important factors in selecting a mechanical prophylactic system, particularly during and after surgery, are patient compliance and the appropriateness of the site of compression. There is no evidence that the peak venous velocity produced by a system is a valid measure of medical performance. Intermittent pneumatic systems for prevention of deep vein thrombosis will have different hemodynamic effects depending on their design. While all systems have been shown to be effective prophylaxis, there is no evidence that a particular compression sequence or construction is more effective than any other in preventing thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scurr, J. H., Machin, S. J., Bailey-King, S., Mackie, I. J., McDonald, S., & Smith, P. D. C. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04645-6 · Cited by 411 · cited 1×
“Exercise devices (air cushions, primarily) have therefore been recommended, along with compression stockings.([84])”
BackgroundElastic compression stockings for prevention of deep vein thrombosis
Sachdeva, A., Dalton, M., Amaragiri, S. V., & Lees, T. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001484.pub2 · Cited by 354
Air-plethysmography and the effect of elastic compression on venous hemodynamics of the leg
Christopoulos, D. G., Nicolaides, A. N., Szendro, G., Irvine, A. T., Bull, M.-L., & Eastcott, H. H. G. (1987) · Journal of Vascular Surgery · doi:10.1016/0741-5214(87)90205-9 · Cited by 336 · cited 1×
“Foot compression, however, needs significantly higher pressures than calf compression, typically 130 mm Hg or more, compared with 40 mm Hg in the calf, there being a small amount of blood in the plantar venous plexus: about 20-30 mL,([27]) compared with 100-150 mL in the calf,([28]) and the muscles are less readily co…”
BackgroundUpper-Extremity Deep Vein Thrombosis: Risk Factors, Diagnosis, and Complications
Prandoni, P. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440220061008 · Cited by 334 · cited 1×
“Intermittent compression of the arms for prevention of DVT at that site is a relatively new area of interest, but upper limb DVT is being reported, particularly associated with central venous catheters.([54]) There are patents for upper-limb cuffs for possible prophylactic devices, but not published experimental data.”
Graduated compression stockings in the prevention of venous thromboembolism
Agu, O., Hamilton, G., & Baker, D. (1999) · Journal of British Surgery · doi:10.1046/j.1365-2168.1999.01195.x · Cited by 296 · cited 1×
“There is growing consensus that they are effective DVT prophylaxis,([57-60]) although perhaps not as effective as anticoagulants or intermittent compression.”
BackgroundThe Fibrinolytic Effects of Intermittent Pneumatic Compression: Mechanism of Enhanced Fibrinolysis
Comerota, A. J., Chouhan, V., Harada, R. N., Sun, L., Hosking, J., Veermansunemi, R., Comerota, A. J., Schlappy, D., & Rao, A. K. (1997) · Annals of Surgery · doi:10.1097/00000658-199709000-00010 · Cited by 249 · cited 1×
“However, since 1976 when Knight and Dawson suggested that applying leg cuffs to the arm prevented DVT in legs,([55]) there has been good research into possible systemic hematological effects, particularly changes in fibrinolysis.([86-92]) Hypercoagulability is another of Virchow's triad, and its prevention, without ha…”
BackgroundWells, P. S. (1994) · Archives of Internal Medicine · doi:10.1001/archinte.154.1.67 · Cited by 235
Graduated, static, external compression of the lower limb: A physiological assessment
Lawrence, D., & Kakkar, V. V. (1980) · Journal of British Surgery · doi:10.1002/bjs.1800670214 · Cited by 217 · cited 1×
“Much of the initial enthusiasm for compression stockings was supported by physiological evidence from radiopharmaceutical clearance,([63-65]) invasive electromagnetic flowmeters,([7]) and early Doppler ultrasound,([66,67]) that intermittent compression increased resting venous blood flow velocities.”
BackgroundSigel, B. (1975) · Archives of Surgery · doi:10.1001/archsurg.1975.01360080037005 · Cited by 214 · cited 1×
“Much of the initial enthusiasm for compression stockings was supported by physiological evidence from radiopharmaceutical clearance,([63-65]) invasive electromagnetic flowmeters,([7]) and early Doppler ultrasound,([66,67]) that intermittent compression increased resting venous blood flow velocities.”
BackgroundWARWICK, D., HARRISON, J., GLEW, D., MITCHELMORE, A., PETERS, T. J., & DONOVAN, J. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199808000-00009 · Cited by 197 · cited 2×
“The outcomes of those trials cannot be used to compare with those from calf compression, as there would be so many confounding factors, but in general it would appear that foot compression is more effective than certain types of heparin and aspirin,([36,37]) and stockings, but perhaps not as effective,([38]) or at lea…”
BackgroundElastic compression stockings for prevention of deep vein thrombosis
Amaragiri, S. V., & Lees, T. (2000) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001484 · Cited by 186 · cited 2×
“There has been suggestion that they are not as useful in certain types of orthopedic surgery as in other procedures([61,62]) but may, in combination with other prophylactic methods, be more effective than it or the other method alone.([60])”
BackgroundFronek, A. S., Criqui, M. H., Denenberg, J. O., & Langer, R. D. (2001) · Journal of Vascular Surgery · doi:10.1067/mva.2001.113496 · Cited by 154 · cited 1×
“Not only will resting blood flow in the femoral vein change from person to person,([23]) but will change in a single subject over time, due to natural fluctuations in the inflow to the limb.”
BackgroundPhysiology and biophysics of the circulation : an introductory text
Burton, A. C. (1965) · Year Book Medical Publishers · Cited by 143
The influence of elastic compression stockings on deep venous hemodynamics
Mayberry, J. C., Moneta, G. L., Frang, R. D. D., & Porter, J. M. (1991) · Journal of Vascular Surgery · doi:10.1016/0741-5214(91)90016-n · Cited by 142
Santori, F. S., Vitullo, A., Stopponi, M., Santori, N., & Ghera, S. (1994) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.76b4.8027144 · Cited by 118 · cited 1×
“The outcomes of those trials cannot be used to compare with those from calf compression, as there would be so many confounding factors, but in general it would appear that foot compression is more effective than certain types of heparin and aspirin,([36,37]) and stockings, but perhaps not as effective,([38]) or at lea…”
BackgroundPrevention of deep-vein thrombosis after total knee replacement
Blanchard, J., Meuwly, J., Leyvraz, P. F., Miron, M. ‐., Bounameaux, H., Hoffmeyer, P. J., Didier, D., & Schneider, P. A. (1999) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.81b4.9464 · Cited by 116 · cited 1×
“The outcomes of those trials cannot be used to compare with those from calf compression, as there would be so many confounding factors, but in general it would appear that foot compression is more effective than certain types of heparin and aspirin,([36,37]) and stockings, but perhaps not as effective,([38]) or at lea…”
BackgroundMeasurement of volume flow in the human common femoral artery using a duplex ultrasound system
Lewis, P., Psaila, J. V., Davies, W. T., McCarty, K., & Woodcock, J. P. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90075-x · Cited by 116 · cited 1×
“Not only will resting blood flow in the femoral vein change from person to person,([23]) but will change in a single subject over time, due to natural fluctuations in the inflow to the limb.([24]) The pattern of flow will change according to the particular physiology and body position at the time, with breathing and t…”
BackgroundSelf-citationVanek, V. W. (1998) · PubMed · Cited by 111
Graduated Compression Stockings: Knee Length or Thigh Length
Benk, T., Cooke, E. A., McNally, M., & Mollan, R. A. B. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200102000-00022 · Cited by 111 · cited 1×
“Thigh-length stockings, in particular, appear to be difficult to apply and wear in some circumstances, and some have preferred calf-length stockings for that reason.([75-77]) More worrying are studies of thigh-length,([78]) and calf-length([79]) stockings in clinical settings where the large majority of the stockings…”
BackgroundCornwell, E. E., Chang, D. C., Velmahos, G. C., Jindal, A., Baker, D. C., Phillips, J., Bonar, J. P., & Campbell, K. A. (2002) · The American Surgeon · doi:10.1177/000313480206800515 · Cited by 106 · cited 2×
“However, these issues can be resolved with training and education, particularly in the correct application of the devices,([31,99]) and use before, during, and after surgery.”
BackgroundSalzman, E. W., McManama, G., Shapiro, A. H., Robertson, L. K., DONOVAN, A. S., Blume, H. W., SWEENEY, J., Kamm, R. D., Johnson, M., & Black, P. M. (1987) · Annals of Surgery · doi:10.1097/00000658-198711000-00014 · Cited by 97 · cited 2×
“In that regard, there is no evidence that they are significantly better, as concluded early on in a paper by Salzman et al,44 among whose authors were Kamm and Shapiro who were instrumental in designing a graded sequential system.”
BackgroundDelis, K. T., Slimani, G., Hafez, H. M., & Nicolaides, A. N. (2000) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.1999.1048 · Cited by 91 · cited 5×
“The venous volume ejected by foot compression will always be lower([16]); therefore, even when”
BackgroundInfluentialGraduated compression stockings: knee length or thigh length.
Benkö, T., Cooke, E. A., McNally, M., & Mollan, R. A. B. (2001) · PubMed · Cited by 90
GRADED COMPRESSION STOCKINGS FOR PREVENTION OF DEEP-VEIN THROMBOSIS AFTER HIP AND KNEE REPLACEMENT
Hui, A. C. W., Heras-Palou, C., Dunn, I., Triffitt, P., Crozier, A., Imeson, J., & Gregg, P. J. (1996) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.78b4.0780550 · Cited by 89
The Effects of External Compression on Venous Blood Flow and Tissue Deformation in the Lower Leg
Dai, G., Gertler, J. P., & Kamm, R. D. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800853 · Cited by 88 · cited 1×
“One study([53]) has used finite-element analysis to model the deformation of a limb under those different compression cuffs.”
BackgroundA simple way to combat the venous stasis which occurs in the lower limbs during surgical operations
Doran, F. S. A., Drury, M. I., & Sivyer, A. (1964) · British journal of surgery · doi:10.1002/bjs.1800510705 · Cited by 83 · cited 1×
“Electrical stimulation had been used to produce muscle contraction, to stimulate the natural muscle pump,([4-6]) but the intermittent compression methodology that already existed for treatment of lymphedema was soon adapted as an alternative that was more suitable for postsurgical application, since it was painless.”
Levine, M. N., Gent, M., Hirsh, J., Weitz, J., Turpie, A. G., Powers, P., Neemeh, J., Willan, A., & Skingley, P. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.156.8.851 · Cited by 82
Sabri, S., Roberts, V. C., & Cotton, L. T. (1971) · BMJ · doi:10.1136/bmj.4.5784.394 · Cited by 73 · cited 2×
“Electrical stimulation had been used to produce muscle contraction, to stimulate the natural muscle pump,([4-6]) but the intermittent compression methodology that already existed for treatment of lymphedema was soon adapted as an alternative that was more suitable for postsurgical application, since it was painless.([…”
BackgroundMethodBailey, J. P., Kruger, M. P., Solano, F. X., Zajko, A. B., & Rubash, H. E. (1991) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(08)80053-8 · Cited by 58 · cited 1×
“There remains little research into the relative physiological and medical merits of these different cuff formats, except to say that both circumferential (boot or cylinder type,([47,48]) and wrap-around([49,50])) and noncircumferential([51,52]) have been used with success in DVT prophylaxis, and both have been shown t…”
BackgroundVenous hemodynamics during impulse foot pumping
Killewich, L. A., Sandager, G. P., Nguyen, A. H., Lilly, M. P., & Flinn, W. R. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(95)70046-3 · Cited by 57 · cited 1×
“There is good recent evidence that foot compression is hemodynamically effective,([13-19,32-34]) typically showing doubling of peak velocities on compression compared with resting, with some small differences between systems.”
BackgroundOptimal Electrical Stimulus for Prevention of Deep Vein Thrombosis
Nicolaides, A. N., Kakkar, V. V., Field, E. S., & Fish, P. J. (1972) · BMJ · doi:10.1136/bmj.3.5829.756 · Cited by 54 · cited 1×
“Electrical stimulation had been used to produce muscle contraction, to stimulate the natural muscle pump,([4-6]) but the intermittent compression methodology that already existed for treatment of lymphedema was soon adapted as an alternative that was more suitable for postsurgical application, since it was painless.”
Venous haemodynamics after total knee arthroplasty
Westrich, G. H., Specht, L. M., Sharrock, N. E., Windsor, R. E., Sculco, T. P., Haas, S. B., Trombley, J., & Peterson, M. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b6.8627 · Cited by 52 · cited 6×
“At pressures around 40 mm Hg, the typical maximum velocities achieved with calf and/or thigh compression would be 35-60 cm/s([11-13,17]) with augmentations (maximum velocity during compression compared with maximum velocity resting) at around 50-250%.([10,12,14,17]) Corresponding popliteal velocities are around 55 cm/…”
BackgroundInfluentialExternal pneumatic compression and fibrinolysis in abdominal surgery
Cahan, M. A., Hanna, D. J., Wiley, L. A., Cox, D. K., & Killewich, L. A. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.107572 · Cited by 45 · cited 1×
“However, since 1976 when Knight and Dawson suggested that applying leg cuffs to the arm prevented DVT in legs,([55]) there has been good research into possible systemic hematological effects, particularly changes in fibrinolysis.([86-92]) Hypercoagulability is another of Virchow's triad, and its prevention, without ha…”
BackgroundFlam, E., Berry, S. M., Coyle, A., Dardik, H., & Raab, L. (1996) · The American Journal of Surgery · doi:10.1016/s0002-9610(97)89632-8 · Cited by 44 · cited 5×
“At pressures around 40 mm Hg, the typical maximum velocities achieved with calf and/or thigh compression would be 35-60 cm/s([11-13,17]) with augmentations (maximum velocity during compression compared with maximum velocity resting) at around 50-250%.([10,12,14,17]) Corresponding popliteal velocities are around 55 cm/…”
BackgroundInfluentialEffect of lightweight compression stockings on venous haemodynamics.
Ibegbuna, V., Delis, K. T., & Nicolaides, A. N. (1997) · PubMed · Cited by 42
The venous footpump: influence on tissue perfusion and prevention of venous thrombosis.
Gardner, A. M. N., & Fox, R. H. (1992) · Annals of the Rheumatic Diseases · doi:10.1136/ard.51.10.1173 · Cited by 42 · cited 1×
“Foot compression, however, needs significantly higher pressures than calf compression, typically 130 mm Hg or more, compared with 40 mm Hg in the calf, there being a small amount of blood in the plantar venous plexus: about 20-30 mL,([27]) compared with 100-150 mL in the calf,([28]) and the muscles are less readily co…”
BackgroundMacklon, N., & Greer, I. A. (1995) · British Journal of Radiology · doi:10.1259/0007-1285-68-809-515 · Cited by 38 · cited 1×
“Some later studies using modern duplex ultrasound techniques have found no increases in resting flow velocity when stockings are worn.([11,21,69]) The diameter of veins under stockings has been found to reduce,([70]) and there have been measurements of changes in indices such as venous volume, and ejection fraction af…”
BackgroundProspective Double-Arm Study of Fibrinolysis in Surgical Patients
Kosir, M. A., Schmittinger, L., Barno-Winarski, L., Duddella, P., Pone, M., Perales, A., Lange, P. A., Brish, L. K., McGee, K. H., Beleski, K., et al. (1998) · Journal of Surgical Research · doi:10.1006/jsre.1997.5233 · Cited by 34 · cited 1×
“However, since 1976 when Knight and Dawson suggested that applying leg cuffs to the arm prevented DVT in legs,([55]) there has been good research into possible systemic hematological effects, particularly changes in fibrinolysis.([86-92]) Hypercoagulability is another of Virchow's triad, and its prevention, without ha…”
BackgroundPrevention of pulmonary embolism by a foot sole pump
Asano, H., Matsubara, M., Suzuki, K., Morita, S., & Shinomiya, K. (2001) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.83b8.11938 · Cited by 31
Buhs, C. L., Bendick, P. J., & Glover, J. L. (1999) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(99)70007-8 · Cited by 31 · cited 1×
“Under normal circumstances, the greatest diameter of the common femoral vein is approximately 16 mm,([21]) the popliteal vein is 8 mm,([21]) and the posterior tibial vein 4 mm.([22]) Therefore, for a given amount of blood being ejected from, for instance, the foot, the velocities achieved would be expected to be highe…”
BackgroundNorgren, L. (1988) · PubMed · Cited by 26
PIDALA, M. J., Donovan, D., & Kepley, R. F. (1993) · Survey of Anesthesiology · doi:10.1097/00132586-199302000-00023 · Cited by 24
Psychometric Considerations When Measuring Cognitive Decline in Alzheimer’s Disease
Nyenhuis, D. L., & Garron, D. C. (1997) · Neuroepidemiology · doi:10.1159/000109686 · Cited by 15
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Pineo, G. F., Heit, J. A., Bergqvist, D., Lassen, M. R., Colwell, C. W., & Ray, J. G. (2004) · Chest · doi:10.1378/chest.126.3_suppl.338s · Cited by 5,895
Prevention of Venous Thromboembolism
Geerts, W. H., Bergqvist, D., Pineo, G. F., Heit, J. A., Samama, C. M., Lassen, M. R., & Colwell, C. W. (2008) · Chest · doi:10.1378/chest.08-0656 · Cited by 3,829
Knudson, M. M., Ikossi, D. G., Khaw, L., Morabito, D., & Speetzen, L. S. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000137138.40116.6c · Cited by 489
Reduced physical activity increases intermuscular adipose tissue in healthy young adults
Manini, T. M., Clark, B. C., Nalls, M. A., Goodpaster, B. H., Ploutz-Snyder, L. L., & Harris, T. B. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.2.377 · Cited by 332
Textile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Metadata
- Authors
- Morris, R. J., & Woodcock, J. P.
- Venue
- Annals of Surgery
- Published
- 2004-02
- Volume
- 239
- Issue
- 2
- Pages
- 162-171
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2158607342
- Cited by
- 221
- References
- 43
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.