The DOI matches its Crossref record.
Establishment of the World's First Telerobotic Remote Surgical Service: For Provision of Advanced Laparoscopic Surgery in a Rural Community
Open accessAbstract
In Brief Objective: To establish a telerobotic surgical service between a teaching hospital and a rural hospital for provision of telerobotic surgery and assistance to aid rural surgeons in providing a variety of advanced laparoscopic surgery to their community patients. Summary Background Data: The above service was established between St. Joseph's Hospital in Hamilton and North Bay General Hospital 400 km north of Hamilton on February 28, 2003. The service uses an IP-VPN (15 Mbps of bandwidth) commercially available network to connect the robotic console in Hamilton with 3 arms of the Zeus-TS surgical system in North Bay. Results: To date, 21 telerobotic laparoscopic surgeries have taken place between North Bay and Hamilton, including 13 fundoplications, 3 sigmoid resections, 2 right hemicolectomies, 1 anterior resection, and 2 inguinal hernia repairs. The 2 surgeons were able to operate together using the same surgical footprint and interchange roles seamlessly when desired. There have been no serious intraoperative complications and no cases have had to be converted to open surgeries. The mean hospital stays were equivalent to mean laparoscopic LOS in the tertiary institution. Conclusions: Telerobotic remote surgery is now in routine use, providing high-quality laparoscopic surgical services to patients in a rural community and providing a superior degree of collaboration between surgeons in teaching hospitals and rural hospitals. Further refinement of the robotic and telecommunication technology should ensure its wider application in the near future. We report the establishment of the world's first clinical telerobotic remote surgical service between a teaching hospital in Hamilton, Ontario and a rural community hospital in North Bay, Ontario, how the service was established, and a brief report of our experience with the first 21 telerobotic remote advanced laparoscopic procedures performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nevo, S., & Wade, M. R. (2010) · MIS Quarterly · doi:10.2307/20721419 · Cited by 517
Origins of Robotic Surgery: From Skepticism to Standard of Care
George, E. I., Brand, T. C., LaPorta, A., Marescaux, J., & Satava, R. M. (2018) · JSLS : Journal of the Society of Laparoendoscopic Surgeons · doi:10.4293/jsls.2018.00039 · Cited by 312
Miniature in vivo Robots for Remote and Harsh Environments
Rentschler, M. E., Platt, S. R., Berg, K. R., Dumpert, J., Oleynikov, D. R., & Farritor, S. M. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.898017 · Cited by 31
Metadata
- Authors
- Anvari, M., McKinley, C., & Stein, H.
- Venue
- Annals of Surgery
- Published
- 2005-03
- Volume
- 241
- Issue
- 3
- Pages
- 460-464
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2137983914
- Cited by
- 237
- References
- 0
- FWCI
- 13.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Establishment of the World's First Telerobotic Remote Surgical Service: For Provision of Advanced Laparoscopic Surgery in a Rural Community. https://app.cochat.ai/papers/10.1097/01.sla.0000154456.69815.ee
- The paper
- Anvari, M., McKinley, C., & Stein, H. (2005). Establishment of the World's First Telerobotic Remote Surgical Service: For Provision of Advanced Laparoscopic Surgery in a Rural Community. Annals of Surgery. https://doi.org/10.1097/01.sla.0000154456.69815.ee
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.