The DOI matches its Crossref record.
A Prospective Comparison of Robotic and Laparoscopic Pyeloplasty
Abstract
OBJECTIVE: To determine whether robotic-assisted pyeloplasty (RLP) has any significant clinical or cost advantages over laparoscopic pyeloplasty (LP) for surgeons already facile with intracorporeal suturing. SUMMARY BACKGROUND DATA: LP has become an established management approach for primary ureteropelvic junction obstruction. More recently, the da Vinci robot has been applied to this procedure (RLP) in an attempt to shorten the learning curve. Whether RLP provides any significant advantage over LP for the experienced laparoscopist remains unclear. METHODS: Ten consecutive cases each of transperitoneal RLP and LP performed by a single surgeon were compared prospectively with respect to surgical times and perioperative outcomes. Cost assessment was performed by sensitivity analysis using a mathematical cost model incorporating operative time, anesthesia fees, consumables, and capital equipment depreciation. RESULTS: The RLP and LP groups had statistically indistinguishable demographics, pathology, and similar perioperative outcomes. Mean operative and total room time for RLP was significantly longer than LP by 19.5 and 39.0 minutes, respectively. RLP was much more costly than LP (2.7 times), due to longer operative time, increased consumables costs, and depreciation of the costly da Vinci system. However, even if depreciation was eliminated, RLP was still 1.7 times as costly as LP. One-way sensitivity analysis showed that LP operative time must increase to almost 6.5 hours for it to become cost equivalent to RLP. CONCLUSIONS: For the experienced laparoscopist, application of the da Vinci robot resulted in no significant clinical advantage and added substantial cost to transperitoneal laparoscopic dismembered pyeloplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kang, S.-W., Lee, S. C., Lee, S. H., Lee, K. Y., Jeong, J. J., Lee, Y. S., Nam, K.-H., Chang, H. S., Chung, W. Y., & Park, C. S. (2009) · Surgery · doi:10.1016/j.surg.2009.09.007 · Cited by 447
Robot-assisted endoscopic surgery for thyroid cancer: experience with the first 100 patients
Kang, S.-W., Jeong, J. J., Yun, J.-S., Sung, T. Y., Lee, S. C., Lee, Y. S., Nam, K.-H., Chang, H. S., Chung, W. Y., & Park, C. S. (2009) · Surgical Endoscopy · doi:10.1007/s00464-009-0366-x · Cited by 390
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Metadata
- Authors
- Link, R. E., Bhayani, S. B., & Kavoussi, L. R.
- Venue
- Annals of Surgery
- Published
- 2006-04
- Volume
- 243
- Issue
- 4
- Pages
- 486-491
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2075146883
- Cited by
- 200
- References
- 0
- FWCI
- 16.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Prospective Comparison of Robotic and Laparoscopic Pyeloplasty. https://app.cochat.ai/papers/10.1097/01.sla.0000205626.71982.32
- The paper
- Link, R. E., Bhayani, S. B., & Kavoussi, L. R. (2006). A Prospective Comparison of Robotic and Laparoscopic Pyeloplasty. Annals of Surgery. https://doi.org/10.1097/01.sla.0000205626.71982.32
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.