Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients?
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Our recent experimental study showed that peripheral muscle tissue oxygen saturation (StO2), determined noninvasively by near-infrared spectroscopy (NIRS), was more reliable than systemic hemodynamics or invasive oxygenation variables as an index of traumatic shock. The purpose of this study was to establish the normal range of thenar muscle StO2 in humans and the relationship between shock state and StO2 in trauma patients. METHODS: This was a prospective, nonrandomized, observational, descriptive study in normal human volunteers (n = 707) and patients admitted to the resuscitation area of our Level I trauma center (n = 150). To establish a normal StO2 range, an NIRS probe was applied to the thenar eminence of volunteers (normals). Subsequently, in a group of trauma patients, an NIRS probe was applied to the thenar eminence and data were collected and stored for offline analysis. StO2 monitoring was performed continuously and noninvasively, and values were recorded at 2-minute intervals. Five moribund trauma patients were excluded. Members of our trauma faculty, blinded to StO2 values, classified each patient into one of four groups (no shock, mild shock, moderate shock, and severe shock) using conventional physiologic parameters. RESULTS: Mean +/- SD thenar StO2 values for each group were as follows: normals, 87 +/- 6% (n = 707); no shock, 83 +/- 10% (n = 85); mild shock, 83 +/- 10% (n = 19); moderate shock, 80 +/- 12% (n = 14); and severe shock, 45 +/- 26% (n = 14). The thenar StO2 values clearly discriminated the normals or no shock patients and the patients with severe shock (p < 0.05). CONCLUSION: Decreased thenar muscle tissue oxygen saturation reflects the presence of severe hypoperfusion and near-infrared spectroscopy may be a novel method for rapidly and noninvasively assessing changes in tissue dysoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Outcome after Hemorrhagic Shock in Trauma Patients
Heckbert, S. R., Vedder, N. B., Hoffman, W., Winn, R. K., Hudson, L. D., Jurkovich, G. J., Copass, M. K., Harlan, J. M., Rice, C. L., & Maier, R. V. (1998) · doi:10.1097/00005373-199809000-00022 · Cited by 383
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
In Search of the Optimal End Points of Resuscitation in Trauma Patients: A Review
Porter, J. M., & Ivatury, R. R. (1998) · doi:10.1097/00005373-199805000-00028 · Cited by 238
Wilson, M., Davis, D. P., & Coimbra, R. (2003) · The Journal of Emergency Medicine · doi:10.1016/s0736-4679(03)00042-8 · Cited by 176
Can the cerebral metabolic rate of oxygen be estimated with near-infrared spectroscopy?
Boas, D. A., Strangman, G., Culver, J. P., Hoge, R. D., Jasdzewski, G., Poldrack, R. A., Rosen, B. R., & Mandeville, J. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/311 · Cited by 175
Kishi, K., Kawaguchi, M., Yoshitani, K., Nagahata, T., & Furuya, H. (2003) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-200310000-00002 · Cited by 171
Utility of Near-Infrared Spectroscopy in the Diagnosis of Lower Extremity Compartment Syndrome
Giannotti, G. D., Cohn, S. M., Brown, M., Varela, J. E., McKenney, M. G., & Wiseberg, J. A. (2000) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200003000-00005 · Cited by 137
Self-citationNoninvasive muscle oxygenation to guide fluid resuscitation after traumatic shock
Crookes, B., Cohn, S. M., Burton, E. A., Nelson, J., & Proctor, K. G. (2004) · Surgery · doi:10.1016/j.surg.2003.11.017 · Cited by 87
Self-citationVarela, J. E., Cohn, S. M., Giannotti, G. D., Dolich, M. O., Ramon, H., Wiseberg, J. A., & McKenney, M. G. (2001) · Surgery · doi:10.1067/msy.2001.111695 · Cited by 70
Self-citationContinuous Measurement of Gut pH with Near-Infrared Spectroscopy during Hemorrhagic Shock
Puyana, J. C., Soller, B. R., Zhang, S., & Heard, S. O. (1999) · doi:10.1097/00005373-199901000-00003 · Cited by 61
Cohn, S. M., Varela, J. E., Giannotti, G. D., Dolich, M. O., Brown, M., Feinstein, A., McKenney, M. G., & Spalding, P. (2001) · doi:10.1097/00005373-200104000-00006 · Cited by 60
Self-citationDo the kinetics of peripheral muscle oxygenation reflect systemic oxygen intake?
Kawaguchi, K., Tabusadani, M., Sekikawa, K., Hayashi, Y., & Onari, K. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210000352 · Cited by 52
A CRITICAL ASSESSMENT OF ENDPOINTS OF SHOCK RESUSCITATION
Dabrowski, G. P., Steinberg, S. M., Ferrara, J. J., & FLINT, L. M. (2000) · Surgical Clinics of North America · doi:10.1016/s0039-6109(05)70098-0 · Cited by 38
Cited by
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
Cohn, S. M., Nathens, A. B., Moore, F. A., Rhee, P., Puyana, J. C., Moore, E. E., & Beilman, G. J. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31802eb817 · Cited by 294
Self-citationDamage control resuscitation: A sensible approach to the exsanguinating surgical patient
Beekley, A. C. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31817da7dc · Cited by 244
DYNAMIC NEAR-INFRARED SPECTROSCOPY MEASUREMENTS IN PATIENTS WITH SEVERE SEPSIS
Skarda, D. E., Mulier, K. E., Myers, D. E., Taylor, J. H., & Beilman, G. J. (2007) · Shock · doi:10.1097/01.shk.0000239779.25775.e4 · Cited by 183
“In hemorrhagic shock, StO2 correlates with severity of hypovolemia, suggesting a role for NIRS as a marker for mild hypovolemia in patients with severe sepsis (35).”
BackgroundGómez, H., Mesquida, J., Simon, P., Kim, H. K., Puyana, J. C., Ince, C., & Pinsky, M. R. (2009) · Critical Care · doi:10.1186/cc8001 · Cited by 94
“The absolute StO2 has been proven instrumental in predicting outcome in trauma patients [1,2].”
Background
Metadata
- Authors
- Crookes, B. A., Cohn, S. M., Bloch, S., Amortegui, J., Manning, R., Li, P., Proctor, M. S., Hallal, A., Blackbourne, L. H., Benjamin, R., Soffer, D., Habib, F., Schulman, C. I., Duncan, R., & Proctor, K. G.
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 2005-04
- Volume
- 58
- Issue
- 4
- Pages
- 806-816
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W2002010869
- Cited by
- 211
- References
- 14
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.