Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

DYNAMIC NEAR-INFRARED SPECTROSCOPY MEASUREMENTS IN PATIENTS WITH SEVERE SEPSIS

Skarda, David E., Mulier, Kristine E., Myers, Dean E., Taylor, Jodie H., Beilman, Greg J.·2007·Shock

Abstract

This study evaluated near-infrared spectroscopy (NIRS)-derived measurements in hemodynamically stable patients with severe sepsis, as compared with similar measurements in healthy age-matched volunteers. Prospective, preliminary, observational study in a surgical intensive care unit and clinical research center at a university health center. We enrolled 10 patients with severe sepsis and 9 healthy age-matched volunteers. For patients with severe sepsis, we obtained pulmonary artery catheter and laboratory values three times daily for 3 days and oxygen consumption values via metabolic cart once daily for 3 days. For healthy volunteers, we obtained all noninvasive measurements during a single session. We found lower values in patients with severe sepsis (versus healthy volunteers), in tissue oxygen saturation (StO2), in the StO2 recovery slope, in the tissue hemoglobin index, and in the total tissue hemoglobin increase on venous occlusion. Patients with severe sepsis had longer StO2 recovery times and lower NIRS-derived local oxygen consumption values versus healthy volunteers. In our preliminary study, NIRS provides a noninvasive continuous method to evaluate peripheral tissue oxygen metabolism in hemodynamically stable patients with severe sepsis. Further research is needed to demonstrate whether these values apply to broader populations of patients with systemic inflammatory response syndrome, sepsis, severe sepsis, and septic shock.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.shk.0000239779.25775.e4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 183

Metadata

Authors
Skarda, D. E., Mulier, K. E., Myers, D. E., Taylor, J. H., & Beilman, G. J.
Venue
Shock
Published
2007-04
Volume
27
Issue
4
Pages
348-353
ISSN
1073-2322 (ISSN-L)
OpenAlex
W1993119495
Cited by
183
References
1
FWCI
8.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: DYNAMIC NEAR-INFRARED SPECTROSCOPY MEASUREMENTS IN PATIENTS WITH SEVERE SEPSIS. https://app.cochat.ai/papers/10.1097/01.shk.0000239779.25775.e4
The paper
Skarda, D. E., Mulier, K. E., Myers, D. E., Taylor, J. H., & Beilman, G. J. (2007). DYNAMIC NEAR-INFRARED SPECTROSCOPY MEASUREMENTS IN PATIENTS WITH SEVERE SEPSIS. Shock. https://doi.org/10.1097/01.shk.0000239779.25775.e4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.