Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 557

The DOI matches its Crossref record.

Functional bioengineered corneal epithelial sheet grafts from corneal stem cells expanded ex vivo on a temperature-responsive cell culture surface

Nishida, Kohji, Yamato, Masayuki, Hayashida, Yasutaka, Watanabe, Katsuhiko, Maeda, Naoyuki, Watanabe, Hitoshi, Yamamoto, Kazuaki, Nagai, Shigeru, Kikuchi, Akihiko, Tano, Yasuo, Okano, Teruo·2004·Transplantation

Abstract

BACKGROUND: Limbal stem-cell deficiency by ocular trauma or diseases causes corneal opacification and visual loss. Recent attempts have been made to fabricate corneal epithelial graft constructs, but the technology is still evolving. We have developed a novel cell-sheet manipulation technology using temperature-responsive culture surfaces to generate functional, cultivated corneal epithelial cell sheet grafts. METHODS: Human or rabbit limbal stem cells were cocultured with mitomycin C-treated 3T3 feeder layers on temperature-responsive culture dishes at 37 degrees C. Cell sheets were harvested from the dishes after 2 weeks by reducing temperature to 20 degrees C. Histologic analyses, immunoblotting, and colony-forming assay were performed to characterize the cell sheets. Autologous transplantation was undertaken to reconstruct the corneal surfaces of rabbits with experimentally induced limbal stem cell deficiencies. RESULTS: Multilayered corneal epithelial sheets were harvested intact simply by reducing the temperature, without the use of proteases. Cell-cell junctions and extracellular matrix on the basal side of the sheet, critical to sheet integrity and function, remained intact. A viable population of corneal progenitor cells, close in number to that originally seeded, was found in the sheets. Harvested sheets were easily manipulated, transplantable without any carriers, and readily adhesive to corneal stroma so that suturing was not required. Corneal surface reconstruction in rabbits was highly successful. CONCLUSIONS: Cell sheet engineering technology allows us to create intact, transplantable corneal epithelial cell sheets that retain stem cells from limbal stem cells expanded ex vivo. Our research indicates highly promising clinical capabilities for our bioengineered corneal epithelial sheet.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.tp.0000110320.45678.30

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 557

Metadata

Authors
Nishida, K., Yamato, M., Hayashida, Y., Watanabe, K., Maeda, N., Watanabe, H., Yamamoto, K., Nagai, S., Kikuchi, A., Tano, Y., & Okano, T.
Venue
Transplantation
Published
2004-02
Volume
77
Issue
3
Pages
379-385
ISSN
0041-1337 (ISSN-L)
OpenAlex
W2118596455
Cited by
557
References
0
FWCI
24.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functional bioengineered corneal epithelial sheet grafts from corneal stem cells expanded ex vivo on a temperature-responsive cell culture surface. https://app.cochat.ai/papers/10.1097/01.tp.0000110320.45678.30
The paper
Nishida, K., Yamato, M., Hayashida, Y., Watanabe, K., Maeda, N., Watanabe, H., Yamamoto, K., Nagai, S., Kikuchi, A., Tano, Y., & Okano, T. (2004). Functional bioengineered corneal epithelial sheet grafts from corneal stem cells expanded ex vivo on a temperature-responsive cell culture surface. Transplantation. https://doi.org/10.1097/01.tp.0000110320.45678.30

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.