The DOI matches its Crossref record.
Corneal Reconstruction with Tissue-Engineered Cell Sheets Composed of Autologous Oral Mucosal Epithelium
Open accessAbstract
BACKGROUND: Ocular trauma or disease may lead to severe corneal opacification and, consequently, severe loss of vision as a result of complete loss of corneal epithelial stem cells. Transplantation of autologous corneal stem-cell sources is an alternative to allograft transplantation and does not require immunosuppression, but it is not possible in many cases in which bilateral disease produces total corneal stem-cell deficiency in both eyes. We studied the use of autologous oral mucosal epithelial cells as a source of cells for the reconstruction of the corneal surface. METHODS: We harvested 3-by-3-mm specimens of oral mucosal tissue from four patients with bilateral total corneal stem-cell deficiencies. Tissue-engineered epithelial-cell sheets were fabricated ex vivo by culturing harvested cells for two weeks on temperature-responsive cell-culture surfaces with 3T3 feeder cells that had been treated with mitomycin C. After conjunctival fibrovascular tissue had been surgically removed from the ocular surface, sheets of cultured autologous cells that had been harvested with a simple reduced-temperature treatment were transplanted directly to the denuded corneal surfaces (one eye of each patient) without sutures. RESULTS: Complete reepithelialization of the corneal surfaces occurred within one week in all four treated eyes. Corneal transparency was restored and postoperative visual acuity improved remarkably in all four eyes. During a mean follow-up period of 14 months, all corneal surfaces remained transparent. There were no complications. CONCLUSIONS: Sutureless transplantation of carrier-free cell sheets composed of autologous oral mucosal epithelial cells may be used to reconstruct corneal surfaces and can restore vision in patients with bilateral severe disorders of the ocular surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gurtner, G. C., Werner, S., Barrandon, Y., & Longaker, M. T. (2008) · Nature · doi:10.1038/nature07039 · Cited by 6,542
Scaffolding in tissue engineering: general approaches and tissue-specific considerations
Chan, B. P., & Leong, K. W. (2008) · European Spine Journal · doi:10.1007/s00586-008-0745-3 · Cited by 1,708
Shimizu, T., Sekine, H., Yang, J., Isoi, Y., Yamato, M., Kikuchi, A., Kobayashi, E., & Okano, T. (2006) · The FASEB Journal · doi:10.1096/fj.05-4715fje · Cited by 478
Self-citationHinderer, S., Layland, S. L., & Schenke-Layland, K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.019 · Cited by 469
Fully functional bioengineered tooth replacement as an organ replacement therapy
Ikeda, E., Morita, R., Nakao, K., Ishida, K., Nakamura, T., Takano-Yamamoto, T., Ogawa, M., Mizuno, M., Kasugai, S., & Tsuji, T. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902944106 · Cited by 447
Metadata
- Authors
- Nishida, K., Yamato, M., Hayashida, Y., Watanabe, K., Yamamoto, K., Adachi, E., Nagai, S., Kikuchi, A., Maeda, N., Watanabe, H., Okano, T., & Tano, Y.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2004-09-16
- Volume
- 351
- Issue
- 12
- Pages
- 1187-1196
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2123630792
- Cited by
- 1,513
- References
- 0
- FWCI
- 36.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corneal Reconstruction with Tissue-Engineered Cell Sheets Composed of Autologous Oral Mucosal Epithelium. https://app.cochat.ai/papers/10.1056/nejmoa040455
- The paper
- Nishida, K., Yamato, M., Hayashida, Y., Watanabe, K., Yamamoto, K., Adachi, E., Nagai, S., Kikuchi, A., Maeda, N., Watanabe, H., Okano, T., & Tano, Y. (2004). Corneal Reconstruction with Tissue-Engineered Cell Sheets Composed of Autologous Oral Mucosal Epithelium. New England Journal of Medicine. https://doi.org/10.1056/nejmoa040455
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.