Changes in skin conductance as a tool to monitor nociceptive stimulation and pain
Abstract
PURPOSE OF REVIEW: The skin conductance algesimeter (SCA) reflects the sympathetic nervous system influenced by changes in emotions, which releases the acetylcholine that acts on muscarine receptors, causing a subsequent burst of sweat and increased skin conductance. The SCA reacts immediately and is not influenced by hemodynamic variability or neuromuscular blockade. The use of SCA for pain and nociceptive assessment is outlined in this review. RECENT FINDINGS: When pain was monitored by verbal reporting in postoperative patients, the SCA had a sensitivity of about 90% and specificity up to 74% to identify the pain, better than heart rate and blood pressure. In general anesthetized patients, both the sensitivity and specificity were about 90% to detect responses to noxious stimulation when compared with clinical stress variables. The SCA reflects changes in norepeinephrine levels induced by nociception better than heart rate, blood pressure, and electroencephalograph (EEG) monitors. Unlike EEG monitors, the SCA response is sensitive to experimental noxious stimuli during general anesthesia, and the measured response was attenuated by analgesic medication. This SCA response is significantly associated with genetically modulated pain sensitivity. Moreover, noxious stimuli in artificially ventilated patients and in preterm infants increase the SCA index, and the increase correlates to the clinical discomfort. SUMMARY: The SCA detects nociceptive pain fast and continuously, specific to the individual, with higher sensitivity and specificity than other available objective methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Persistent postsurgical pain: risk factors and prevention
Kehlet, H., Jensen, T. S., & Woolf, C. J. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68700-x · Cited by 4,086
Pandharipande, P., Shintani, A., Peterson, J., Pun, B. T., Wilkinson, G. R., Dittus, R. S., Bernard, G. R., & Ely, E. W. (2006) · Anesthesiology · doi:10.1097/00000542-200601000-00005 · Cited by 1,238
Effect of neonatal circumcision on pain response during subsequent routine vaccination
Taddio, A., Katz, J., Ilersich, A. L., & Koren, G. (1997) · The Lancet · doi:10.1016/s0140-6736(96)10316-0 · Cited by 1,218
The behavioural states of the newborn infant (a review)
Prechtl, H. F. R. (1974) · Brain Research · doi:10.1016/0006-8993(74)90454-5 · Cited by 1,170
Anand, K. J. S., & Hickey, P. R. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201023260101 · Cited by 853
Myles, P. S., Williams, D. L., Hendrata, M., Anderson, H., & Weeks, A. M. (2000) · British Journal of Anaesthesia · doi:10.1093/oxfordjournals.bja.a013383 · Cited by 770
The Incidence of Awareness During Anesthesia: A Multicenter United States Study
Sebel, P. S., Bowdle, T. A., Ghoneim, M. M., Rampil, I. J., Padilla, R. E., Gan, T. J., & Domino, K. B. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000130261.90896.6c · Cited by 722
General Characteristics of Sympathetic Activity in Human Skin Nerves
Hagbarth, K. ‐., Hallin, R. G., Hongell, A., Torebjörk, H. E., & Wallin, B. G. (1972) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1972.tb05167.x · Cited by 688
Rotondi, A. J., Chelluri, L., Sirio, C., Mendelsohn, A., Schulz, R., Belle, S., Im, K., Donahoe, M., & Pinsky, M. R. (2002) · Critical Care Medicine · doi:10.1097/00003246-200204000-00004 · Cited by 620
Bini, G., Hagbarth, K. E., Hynninen, P., & Wallin, B. G. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013413 · Cited by 421
Cited by
A continuous measure of phasic electrodermal activity
Benedek, M., & Kaernbach, C. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.028 · Cited by 1,671
Assessing pain objectively: the use of physiological markers
Cowen, R., Stasiowska, M. K., Laycock, H., & Bantel, C. (2015) · Anaesthesia · doi:10.1111/anae.13018 · Cited by 285
Brain activation patterns underlying fast habituation to painful laser stimuli
Mobascher, A., Brinkmeyer, J., Warbrick, T., Musso, F., Schlemper, V., Wittsack, H. J., Saleh, A., Schnitzler, A., & Winterer, G. (2010) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2009.10.008 · Cited by 48
“Based on previous findings on cross-modal relationships between the subjective evaluation of pain and the EDA response (Chapman et al., 2001, 2002; Storm, 2008), between pain/stimulus intensity and the fMRI BOLD signal (Bornhövd et al.”
BackgroundInfluential
Metadata
- Authors
- Storm, H.
- Venue
- Current Opinion in Anaesthesiology
- Published
- 2008-12
- Volume
- 21
- Issue
- 6
- Pages
- 796-804
- ISSN
- 0952-7907 (ISSN-L)
- OpenAlex
- W1984067037
- Cited by
- 260
- References
- 41
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.