The DOI matches its Crossref record.
Lung Ultrasound Predicts Well Extravascular Lung Water but Is of Limited Usefulness in the Prediction of Wedge Pressure
Abstract
Background: Pulmonary congestion is indicated at lung ultrasound by detection of B-lines, but correlation of these ultrasound signs with pulmonary artery occlusion pressure (PAOP) and extravascular lung water (EVLW) still remains to be further explored. The aim of the study was to assess whether B-lines, and eventually a combination with left ventricular ejection fraction (LVEF) assessment, are useful to differentiate low/high PAOP and EVLW in critically ill patients. Methods: The authors enrolled 73 patients requiring invasive monitoring from the intensive care unit of four university-affiliated hospitals. Forty-one patients underwent PAOP measurement by pulmonary artery catheterization and 32 patients had EVLW measured by transpulmonary thermodilution method. Lung and cardiac ultrasound examinations focused to the evaluation of B-lines and gross estimation of LVEF were performed. The absence of diffuse B-lines (A-pattern) versus the pattern showing prevalent B-lines (B-pattern) and the combination with normal or impaired LVEF were correlated with cutoff levels of PAOP and EVLW. Results: PAOP of 18 mmHg or less was predicted by the A-pattern with 85.7% sensitivity (95% CI, 70.5 to 94.1%) and 40.0% specificity (CI, 25.4 to 56.4%), whereas EVLW 10 ml/kg or less with 81.0% sensitivity (CI, 62.6 to 91.9%) and 90.9% specificity (CI, 74.2 to 97.7%). The combination of A-pattern with normal LVEF increased sensitivity to 100% (CI, 84.5 to 100%) and specificity to 72.7% (CI, 52.0 to 87.2%) for the prediction of PAOP 18 mmHg or less. Conclusions: B-lines allow good prediction of pulmonary congestion indicated by EVLW, whereas are of limited usefulness for the prediction of hemodynamic congestion indicated by PAOP. Combining B-lines with estimation of LVEF at transthoracic ultrasound may improve the prediction of PAOP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mullens, W., Damman, K., Harjola, V.-P., Mebazaa, A., Brunner-La Rocca, H.-P., Martens, P., Testani, J. M., Tang, W. H. W., Orso, F., Rossignol, P., et al. (2019) · European Journal of Heart Failure · doi:10.1002/ejhf.1369 · Cited by 1,119
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
Lung Ultrasound-Implemented Diagnosis of Acute Decompensated Heart Failure in the ED
Pivetta, E., Goffi, A., Lupia, E., Tizzani, M., Porrino, G., Ferreri, E., Volpicelli, G., Balzaretti, P., Banderali, A., Iacobucci, A., et al. (2015) · Chest · doi:10.1378/chest.14-2608 · Cited by 405
Self-citation
Metadata
- Authors
- Volpicelli, G., Skurzak, S., Boero, E., Carpinteri, G., Tengattini, M., Stefanone, V., Luberto, L., Anile, A., Cerutti, E., Radeschi, G., & Frascisco, M. F.
- Venue
- Anesthesiology
- Published
- 2014-08
- Volume
- 121
- Issue
- 2
- Pages
- 320-327
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2029976897
- Cited by
- 166
- References
- 0
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lung Ultrasound Predicts Well Extravascular Lung Water but Is of Limited Usefulness in the Prediction of Wedge Pressure. https://app.cochat.ai/papers/10.1097/aln.0000000000000300
- The paper
- Volpicelli, G., Skurzak, S., Boero, E., Carpinteri, G., Tengattini, M., Stefanone, V., Luberto, L., Anile, A., Cerutti, E., Radeschi, G., & Frascisco, M. F. (2014). Lung Ultrasound Predicts Well Extravascular Lung Water but Is of Limited Usefulness in the Prediction of Wedge Pressure. Anesthesiology. https://doi.org/10.1097/aln.0000000000000300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.