CoChat

Accuracy and Feasibility of Clinically Applied Frailty Instruments before Surgery: A Systematic Review and Meta-analysis

Aucoin, Sylvie D., Hao, Mike, Sohi, Raman, Shaw, Julia, Bentov, Itay, Walker, David, McIsaac, Daniel I. · 2020 · Anesthesiology
Cited by 234

The DOI matches its Crossref record; 107 of the 107 references it cites were found in a registry or an index.

Abstract

Background: A barrier to routine preoperative frailty assessment is the large number of frailty instruments described. Previous systematic reviews estimate the association of frailty with outcomes, but none have evaluated outcomes at the individual instrument level or specific to clinical assessment of frailty, which must combine accuracy with feasibility to support clinical practice. Methods: The authors conducted a preregistered systematic review (CRD42019107551) of studies prospectively applying a frailty instrument in a clinical setting before surgery. Medline, Excerpta Medica Database, Cochrane Library and the Comprehensive Index to Nursing and Allied Health Literature, and Cochrane databases were searched using a peer-reviewed strategy. All stages of the review were completed in duplicate. The primary outcome was mortality and secondary outcomes reflected routinely collected and patient-centered measures; feasibility measures were also collected. Effect estimates were pooled using random-effects models or narratively synthesized. Risk of bias was assessed. Results: Seventy studies were included; 45 contributed to meta-analyses. Frailty was defined using 35 different instruments; five were meta-analyzed, with the Fried Phenotype having the largest number of studies. Most strongly associated with: mortality and nonfavorable discharge was the Clinical Frailty Scale (odds ratio, 4.89; 95% CI, 1.83 to 13.05 and odds ratio, 6.31; 95% CI, 4.00 to 9.94, respectively); complications was associated with the Edmonton Frail Scale (odds ratio, 2.93; 95% CI, 1.52 to 5.65); and delirium was associated with the Frailty Phenotype (odds ratio, 3.79; 95% CI, 1.75 to 8.22). The Clinical Frailty Scale had the highest reported measures of feasibility. Conclusions: Clinicians should consider accuracy and feasibility when choosing a frailty instrument. Strong evidence in both domains support the Clinical Frailty Scale, while the Fried Phenotype may require a trade-off of accuracy with lower feasibility. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0000000000003257

Cites

107 of 107 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 107 references

Cited by

See all 234

Metadata

Authors
Aucoin, S. D., Hao, M., Sohi, R., Shaw, J., Bentov, I., Walker, D., & McIsaac, D. I.
Venue
Anesthesiology
Published
2020-03-31
Volume
133
Issue
1
Pages
78-95
ISSN
  • 0003-3022 (ISSN-L)
  • 1528-1175
OpenAlex
W3014401808
Cited by
234
References
107
FWCI
14.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Feasibility of Clinically Applied Frailty Instruments before Surgery: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1097/aln.0000000000003257
The paper
Aucoin, S. D., Hao, M., Sohi, R., Shaw, J., Bentov, I., Walker, D., & McIsaac, D. I. (2020). Accuracy and Feasibility of Clinically Applied Frailty Instruments before Surgery: A Systematic Review and Meta-analysis. Anesthesiology. https://doi.org/10.1097/aln.0000000000003257

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.