CoChat

Electroencephalographic Order Pattern Analysis for the Separation of Consciousness and Unconsciousness: An Analysis of Approximate Entropy, Permutation Entropy, Recurrence Rate, and Phase Coupling of Order Recurrence Plots

Open access
Jordan, Denis, Stockmanns, Gudrun, Kochs, Eberhard F., Pilge, Stefanie, Schneider, Gerhard · 2008 · Anesthesiology
Cited by 137

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Nonlinear electroencephalographic parameters, e.g., approximate entropy, have been suggested as measures of the hypnotic component of anesthesia. Compared with linear methods, they may detect additional information and quantify the irregularity of a dynamical system. High dimensionality of a signal and disturbances may affect these parameters and change their ability to distinguish consciousness from unconsciousness. Methods of order pattern analysis, in this investigation represented by permutation entropy, recurrence rate, and phase coupling of order recurrence plots, are suitable for any type of time series, whether deterministic or noisy. They may provide a better estimation of the hypnotic component of anesthesia than other nonlinear parameters. Methods: The current analysis is based on electroencephalographic data from two similar clinical studies in adult patients undergoing general anesthesia with sevoflurane or propofol. The study period was from induction until patients followed command after surgery, including a reduction of the hypnotic agent after tracheal intubation until patients followed command. Prediction probability was calculated to assess the parameter's ability to separate consciousness from unconsciousness at the transition between both states. Results: Parameters of order pattern analysis provide a prediction probability of maximal 0.85 (training study) and 0.78 (evaluation study) with frequencies from 0 to 30 Hz, and maximal 0.87 (training study) and 0.83 (evaluation study) including frequencies up to 70 Hz, both higher than 0.77 (approximate entropy). Conclusions: Parameters of the nonlinear method order pattern analysis separate consciousness from unconsciousness and are grossly independent of high-frequency components of the electroencephalogram.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e31818d6c55

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 137

Metadata

Authors
Jordan, D., Stockmanns, G., Kochs, E. F., Pilge, S., & Schneider, G.
Venue
Anesthesiology
Published
2008-12-01
Volume
109
Issue
6
Pages
1014-1022
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2031754355
Cited by
137
References
2
FWCI
5.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electroencephalographic Order Pattern Analysis for the Separation of Consciousness and Unconsciousness: An Analysis of Approximate Entropy, Permutation Entropy, Recurrence Rate, and Phase Coupling of Order Recurrence Plots. https://app.cochat.ai/papers/10.1097/aln.0b013e31818d6c55
The paper
Jordan, D., Stockmanns, G., Kochs, E. F., Pilge, S., & Schneider, G. (2008). Electroencephalographic Order Pattern Analysis for the Separation of Consciousness and Unconsciousness: An Analysis of Approximate Entropy, Permutation Entropy, Recurrence Rate, and Phase Coupling of Order Recurrence Plots. Anesthesiology. https://doi.org/10.1097/aln.0b013e31818d6c55

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.