Use of the Pentax-AWS® in 293 Patients with Difficult Airways

Asai, Takashi, Liu, Eugene H., Matsumoto, Sanae, Hirabayashi, Yoshihiro, Seo, Norimasa, Suzuki, Akihiro, Toi, Takashi, Yasumoto, Kazumasa, Okuda, Yasuhisa·2009·Anesthesiology

Abstract

THE Pentax-AWS® (Airway Scope; Hoya Corporation, Tokyo, Japan) (fig. 1), an indirect optical laryngoscope invented by a neurosurgeon Jun-ichi Koyama, M.D., Ph.D. (Department of Neurosugery, Shinshu University School of Medicine, Matsumoto, Japan) has been available in Japan since June 2006.1It consists of a disposable blade (PBlade®; Hoya Corporation), a 12-cm image tube with a charge-coupled device camera, and a handle with a 6-cm liquid crystal display (fig. 1). The image tube is inserted into the PBlade® so that the PBlade® completely encloses and protects the image tube and camera. The PBlade® has a transparent window through which the camera obtains images; the camera eye is 3 cm from the tip of the PBlade®.Several studies have shown that the Pentax-AWS® provides full views of the glottis in the majority of patients.2–5There have been several anecdotal reports of successful tracheal intubation using the Pentax-AWS® in patients after failed intubation using a Macintosh laryngoscope.6–9In addition, tracheal intubation using the Pentax-AWS® has been shown to be easier than conventional tracheal intubation in patients whose heads and necks were immobilized to simulate difficult laryngoscopy conditions.5Suzuki et al. recently reported a high success rate of tracheal intubation using the Pentax-AWS® in 45 patients in whom a clear view of the glottis could not be obtained by using a Macintosh laryngoscope.4In their study, no external pressure to the neck was applied during laryngoscopy (to obtain a better view of the glottis), no endotracheal tube introducer was used, and no attempts were made to intubate the trachea with the Macintosh laryngoscope. Therefore, the usefulness of the Pentax-AWS® in patients in whom tracheal intubation using the Macintosh laryngoscope has failed is not known.The main aim of this report was to obtain the success rate of tracheal intubation using the Pentax-AWS® in a large number of patients in whom difficult tracheal intubation using the Macintosh laryngoscope was experienced as a result of a variety of anatomical and pathologic changes. The second aim was to analyze the reasons for difficulty in tracheal intubation with the Pentax-AWS®.We started to use the Pentax-AWS® after it had been licensed for use in clinical practice in 2006. The institutional research ethics committees of all participating institutions approved the study of summarizing data (from October 2006 to August 2008) and reporting the results. The committees stated that the nature of the study would not require written informed consent from each patient. Nine senior anesthesiologists with more than 10-yr experience in anesthesia practice from seven hospitals participated in this project: Kansai Medical University (Takii and Otokoyama Hospitals), Jichi Medical University Hospital, Asahikawa Medical College Hospital, Showa University Hospital, Dokkyo Medical School, Koshigaya Hospital all in Japan, and National University Hospital in Singapore. Each anesthesiologist had practiced the Pentax-AWS® in mannequins and had used the device in more than ten patients without predicted difficult airways.We prospectively collected cases of the Pentax-AWS® in two groups of patients. In patients in whom orotracheal intubation was indicated, we used a Macintosh laryngoscope after induction of general anesthesia and neuromuscular blockade, when neither difficult tracheal intubation nor difficult mask ventilation was predicted, or when difficult tracheal intubation was predicted but difficult mask ventilation was not predicted. We used the Pentax-AWS® when tracheal intubation using a Macintosh laryngoscope had been difficult (group 1). If both difficult tracheal intubation and difficult mask ventilation were predicted, we used the Pentax-AWS® (before induction of anesthesia and before neuromuscular blockade) without previous use of the Macintosh laryngoscope (group 2). We did not include patients in whom we had used the Pentax-AWS® for insertion of double-lumen tubes or bronchial blockers or for the exchange of tracheal tubes. Patients in whom nasotracheal intubation was required were also not included. To obtain a success rate of tracheal intubation with the Pentax -AWS®, we included 14 patients who have been reported previously.4,6,8,10,11We recorded the patients’ characteristics, preoperative view of the oropharynx (classification according to Mallampati et al. 12and Samsoon and Young13), and the thyromental distance, and we predicted that tracheal intubation using a Macintosh laryngoscope would be difficult when Mallampati was 3 or 4, when the thyromental distance was less than 6 cm, or when the patient was severely or very severely obese (as 35.0 kg/m2or greater, according to the World Health Organization classification). We also recorded the presence of any other factors that might make tracheal intubation difficult.In the operating room, we monitored all patients with electrocardiography, pulse oximetry, and noninvasive blo

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e31819c45e5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Asai, T., Liu, E. H., Matsumoto, S., Hirabayashi, Y., Seo, N., Suzuki, A., Toi, T., Yasumoto, K., & Okuda, Y.
Venue
Anesthesiology
Published
2009-04-01
Volume
110
Issue
4
Pages
898-904
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2094377228
Cited by
186
References
0
FWCI
24.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of the Pentax-AWS® in 293 Patients with Difficult Airways. https://app.cochat.ai/papers/10.1097/aln.0b013e31819c45e5
The paper
Asai, T., Liu, E. H., Matsumoto, S., Hirabayashi, Y., Seo, N., Suzuki, A., Toi, T., Yasumoto, K., & Okuda, Y. (2009). Use of the Pentax-AWS® in 293 Patients with Difficult Airways. Anesthesiology. https://doi.org/10.1097/aln.0b013e31819c45e5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.