The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated Patients
Abstract
Background: Heart-lung interactions are used to evaluate fluid responsiveness in mechanically ventilated patients, but these indices may be influenced by ventilatory conditions. The authors evaluated the impact of respiratory rate (RR) on indices of fluid responsiveness in mechanically ventilated patients, hypothesizing that pulse pressure variation and respiratory variation in aortic flow would decrease at high RRs. Methods: In 17 hypovolemic patients, thermodilution cardiac output and indices of fluid responsiveness were measured at a low RR (14-16 breaths/min) and at the highest RR (30 or 40 breaths/min) achievable without altering tidal volume or inspiratory/expiratory ratio. Results: An increase in RR was accompanied by a decrease in pulse pressure variation from 21% (18-31%) to 4% (0-6%) (P < 0.01) and in respiratory variation in aortic flow from 23% (18-28%) to 6% (5-8%) (P < 0.01), whereas respiratory variations in superior vena cava diameter (caval index) were unaltered, i.e., from 38% (27-43%) to 32% (22-39%), P = not significant. Cardiac index was not affected by the changes in RR but did increase after fluids. Pulse pressure variation became negligible when the ratio between heart rate and RR decreased below 3.6. Conclusions: Respiratory variations in stroke volume and its derivates are affected by RR, but caval index was unaffected. This suggests that right and left indices of ventricular preload variation are dissociated. At high RRs, the ability to predict the response to fluids of stroke volume variations and its derivate may be limited, whereas caval index can still be used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
(2004) · New England Journal of Medicine · doi:10.1056/nejmoa032193 · Cited by 2,565
Cited by
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator
Abdelnasser, H., Harras, K. A., & Youssef, M. (2015) · Proceedings of the 16th ACM International Symposium on Mobile Ad Hoc Networking and Computing · doi:10.1145/2746285.2755969 · Cited by 267
Metadata
- Authors
- De Backer, D., Taccone, F. S., Holsten, R., Ibrahimi, F., & Vincent, J.-L.
- Venue
- Anesthesiology
- Published
- 2009-05-01
- Volume
- 110
- Issue
- 5
- Pages
- 1092-1097
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2143852701
- Cited by
- 207
- References
- 2
- FWCI
- 13.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated Patients. https://app.cochat.ai/papers/10.1097/aln.0b013e31819db2a1
- The paper
- De Backer, D., Taccone, F. S., Holsten, R., Ibrahimi, F., & Vincent, J.-L. (2009). Influence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated Patients. Anesthesiology. https://doi.org/10.1097/aln.0b013e31819db2a1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.