Approach Combining the Airway Scope and the Bougie for Minimizing Movement of the Cervical Spine during Endotracheal Intubation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: The Airway Scope (AWS, AWS-S100; Hoya-Pentax, Tokyo, Japan), a recently introduced video laryngoscope, has been reported to reduce movement of the cervical spine during intubation attempts in comparison with conventional laryngoscopes. Use of the bougie as an aid for the AWS may cause further reduction. The authors compared cervical spine movement during intubation with the AWS with and without a bougie. Methods: Thirty patients without cervical spine abnormality were randomized into two groups: intubation with AWS only and intubation with the AWS and the bougie. The cervical spine motion between the occiput (C0) and the fourth cervical vertebra (C4) was observed fluoroscopically, and change in movement between adjacent vertebrae created by each intubation method was compared. Time to intubation was also measured. Results: Laryngoscopy with the AWS produced extension of the cervical spine segments assessed (C0-4). Median extension angle of the C0-4 during intubation using the AWS was reduced from 16.0 degrees without the bougie to 6.5 degrees with the bougie (P < 0.01). There was no significant difference in time to intubation between them. Conclusions: Use of the bougie resulted in significantly reduced extension of the cervical spine during intubation attempt with the AWS in patients with a normal cervical spine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Airway management in adults after cervical spine trauma
Crosby, E. T., & Warltier, D. C. (2006) · Anesthesiology · doi:10.1097/00000542-200606000-00026 · Cited by 401
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Video‐laryngoscopes in the adult airway management: a topical review of the literature
NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T. (2010) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02285.x · Cited by 316
Neurological deterioration during intubation in cervical spine disorders
Durga, P., & Sahu, B. (2014) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.147132 · Cited by 40
Management of the airway in multitrauma
Dupanovic, M., Fox, H., & Kovac, A. (2010) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e3283360b4f · Cited by 39
Metadata
- Authors
- Takenaka, I., Aoyama, K., Iwagaki, T., Ishimura, H., Takenaka, Y., & Kadoya, T.
- Venue
- Anesthesiology
- Published
- 2009-06-01
- Volume
- 110
- Issue
- 6
- Pages
- 1335-1340
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2093147768
- Cited by
- 52
- References
- 1
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.