The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Video‐laryngoscopes in the adult airway management: a topical review of the literature
Abstract
The aim of the present paper is to review the literature regarding video‐laryngoscopes (Storz V‐Mac and C‐Mac, Glidescope, McGrath, Pentax‐Airway Scope, Airtraq and Bullard) and discuss their clinical role in airway management. Video‐laryngoscopes are new intubation devices, which provide an indirect view of the upper airway. In difficult airway management, they improve Cormack–Lehane grade and achieve the same or a higher intubation success rate in less time, compared with direct laryngoscopes. Despite the very good visualization of the glottis, the insertion and advancement of the endotracheal tube with video‐laryngoscopes may occasionally fail. Each particular device's features may offer advantages or disadvantages, depending on the situation the anaesthesiologist has to deal with. So far, there is inconclusive evidence indicating that video‐laryngoscopy should replace direct laryngoscopy in patients with normal or difficult airways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990) · Anesthesiology · doi:10.1097/00000542-199005000-00010 · Cited by 1,060
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
Konrad, C., Schupfer, G., Wietlisbach, M., & Gerber, H. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199803000-00037 · Cited by 655
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
The unanticipated difficult airway with recommendations for management
Crosby, E. T., Cooper, R. M., Douglas, M. J., Doyle, D. J., Hung, O. R., Labrecque, P., Muir, H., Murphy, M. F., Preston, R. P., Rose, D. K., et al. (1998) · Canadian Journal of Anaesthesia · doi:10.1007/bf03012147 · Cited by 615
Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patients
Cooper, R. M., Pacey, J. A., Bishop, M. J., & McCluskey, S. A. (2005) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03027728 · Cited by 562
Konrad, C., Schupfer, G., Wietlisbach, M., & Gerber, H. (1998) · Anesthesia & Analgesia · doi:10.1213/00000539-199803000-00037 · Cited by 545
The GlideScope® Video Laryngoscope: randomized clinical trial in 200 patients
Sun, D. A., Warriner, C. B., Parsons, D. G., Klein, R., Umedaly, H. S., & Moult, M. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei041 · Cited by 359
Lee, A., Fan, L. T. Y., Gin, T., Karmakar, M. K., & Ngan Kee, W. D. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000217211.12232.55 · Cited by 319
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Michailidou, M., O’Keeffe, T., Mosier, J. M., Friese, R. S., Joseph, B., Rhee, P., & Sakles, J. C. (2015) · World Journal of Surgery · doi:10.1007/s00268-014-2845-z · Cited by 79
Metadata
- Authors
- NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 2010-07-28
- Volume
- 54
- Issue
- 9
- Pages
- 1050-1061
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2133167770
- Cited by
- 316
- References
- 59
- FWCI
- 27.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Video‐laryngoscopes in the adult airway management: a topical review of the literature. https://app.cochat.ai/papers/10.1111/j.1399-6576.2010.02285.x
- The paper
- NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T. (2010). Video‐laryngoscopes in the adult airway management: a topical review of the literature. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/j.1399-6576.2010.02285.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.