CoChat

Use of Serotonergic Antidepressants and Bleeding Risk in Orthopedic Patients

van Haelst, Ingrid M. M., Egberts, Toine C. G., Doodeman, Hieronymus J., Traast, Han S., Burger, Bart J., Kalkman, Cor J., van Klei, Wilton A. · 2010 · Anesthesiology
Cited by 78

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: Selective serotonin reuptake inhibitors have been associated with an increased bleeding tendency. Information on the impact of a possible impaired hemostasis associated with the perioperative use of selective serotonin reuptake inhibitors is limited. This study aimed to determine the association between the perioperative use of selective serotonin reuptake inhibitors and the amount of blood loss during surgery and perioperative transfusion requirements. Methods: The authors conducted a retrospective cohort study among patients who underwent elective primary total hip arthroplasty in two hospitals from the period of July 1, 2004 until July 1, 2008. The index group included all users of both serotonergic and nonserotonergic antidepressants. The reference group included a random sample (ratio 1:3) of nonusers. The primary outcome was the amount of intraoperative blood loss. The requirement for blood transfusion was a secondary outcome. The outcomes were adjusted for confounding factors (comorbidity and comedication) using regression techniques. Results: The index group included 66 users of serotonergic and 29 users of nonserotonergic antidepressants, and the reference group included 285 patients. After adjustment for confounding factors, mean blood loss during surgery was significantly higher in the users of selective serotonin reuptake inhibitors when compared with the reference group: 95 ml (95% CI 9-181). Mean blood loss in the users of nonserotonergic antidepressants did not differ from the reference group. Users of antidepressants did not have a higher risk for transfusion. Conclusions: Patients undergoing total hip arthroplasty who continue the use of serotonergic antidepressants show a significantly higher, but clinically unimportant, intraoperative blood loss, without an increase in perioperative transfusion requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e3181cf8fdf

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
van Haelst, I. M. M., Egberts, T. C. G., Doodeman, H. J., Traast, H. S., Burger, B. J., Kalkman, C. J., & van Klei, W. A.
Venue
Anesthesiology
Published
2010-03-01
Volume
112
Issue
3
Pages
631-636
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2157621441
Cited by
78
References
5
FWCI
3.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.