CoChat

Oxygen and Surgical Site Infection: A Study of Underlying Immunologic Mechanisms

Qadan, Motaz, Battista, Christopher, Gardner, Sarah A., Anderson, Gary, Akca, Ozan, Polk, Hiram C. · 2010 · Anesthesiology
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Recent clinical trials investigating the role of hyperoxia in decreasing surgical site infection have reported conflicting results. Immunologic mechanisms through which supplemental oxygen could act have not been elucidated fully. The authors sought to investigate the effects of hyperoxia on previously tested and prognostically significant innate immune parameters to uncover the potential effects of hyperoxia at the cellular level. Methods: After formal approval and informed consent, venous blood samples were collected from young healthy volunteers. Corresponding samples were incubated at 21 or 80% O2 following a 1 ng/ml lipopolysaccharide challenge and analyzed to determine human leukocyte antigen-DR surface receptor expression, cytokine release, phagocytic capacity, and formation of reactive oxygen species. Data are presented as mean +/- SD. Results: After the 2 h of incubation at 21% O2 (room air) and in 80% O2 chambers, the change in human leukocyte antigen-DR mean channel fluorescence in lipopolysaccharide-stimulated monocytes was 2,177 +/- 383 and 2,179 +/- 338 (P = 0.96), respectively. Tumor necrosis factor-alpha concentrations were significantly lower for samples incubated at 80% O2 when compared with 21% O2 (P < 0.05). The phagocytic capacity of the innate immune system was not significantly enhanced by supplemental oxygen. However, the formation of reactive oxygen species increased by 87% (P < 0.05). Conclusion: Hyperoxia exerts significant effects on multiple cellular and immunologic parameters, providing a potential mechanism for benefits from the use of supplemental oxygen. However, the ability to translate positive basic scientific findings to the operating suite or bedside require the existence of similar innate immune processes in vivo and the efficient transfer of oxygen to the sites where it may be used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e3181e19d1d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 64

Metadata

Authors
Qadan, M., Battista, C., Gardner, S. A., Anderson, G., Akca, O., & Polk, H. C.
Venue
Anesthesiology
Published
2010-08-01
Volume
113
Issue
2
Pages
369-377
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1992036948
Cited by
64
References
1
FWCI
4.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.