Abstract
Background: Formulas based on age and height often fail to reliably predict the proper endotracheal tube (ETT) size in pediatric patients. We, thus, tested the hypothesis that subglottic diameter, as determined by ultrasonography, better predicts optimal ETT size than existing methods. Methods: A total of 192 patients, aged 1 month to 6 yr, who were scheduled for surgery and undergoing general anesthesia were enrolled and divided into development and validation phases. In the development group, the optimal ETT size was selected according to standard age-based formulas for cuffed and uncuffed tubes. Tubes were replaced as necessary until a good clinical fit was obtained. Via ultrasonography, the subglottic upper airway diameter was determined before tracheal intubation. We constructed a regression equation between the subglottic upper airway diameter and the outer diameter of the ETT finally selected. In the validation group, ETT size was selected after ultrasonography using this regression equation. The primary outcome was the fraction of initial cuffed and uncuffed tube sizes, as selected through the regression formula, that proved clinically optimal. Results: Subglottic upper airway diameter was highly correlated with outer ETT diameter deemed optimal on clinical grounds. The rate of agreement between the predicted ETT size based on ultrasonic measurement and the final ETT size selected clinically was 98% for cuffed ETTs and 96% for uncuffed ETTs. Conclusions: Measuring subglottic airway diameter with ultrasonography facilitates the selection of appropriately sized ETTs in pediatric patients. This selection method better predicted optimal outer ETT diameter than standard age- and height-based formulas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power and Sample Size Calculations for Studies Involving Linear Regression
Dupont, W. D., & Plummer, W. D. (1998) · Controlled Clinical Trials · doi:10.1016/s0197-2456(98)00037-3 · Cited by 1,024 · cited 1×
“01.(13) Our primary goal, though, was to determine the extent to which variability in optimal ETT size can be explained by the variability in the tracheal dimension as assessed by ultrasonography.”
BackgroundComparison of Cuffed and Uncuffed Endotracheal Tubes in Young Children during General Anesthesia
Khine, H. H., Corddry, D. H., Kettrick, R. G., Martin, T. M., McCloskey, J. J., Rose, J. B., Theroux, M. C., & Zagnoev, M. (1997) · Anesthesiology · doi:10.1097/00000542-199703000-00015 · Cited by 480 · cited 1×
“We used the OD for our regressions because it can vary by as much as 1 mm at any given ID depending on the manufacturer.(16) –18 A report on the feasibility of ultrasound to assess subglottic diameter showed a strong correlation between ultrasonography and magnetic resonance image measurements of the”
MethodExtubation failure in pediatric intensive care: A multiple-center study of risk factors and outcomes
Kurachek, S. C., Newth, C. J., Quasney, M. W., Rice, T., Sachdeva, R. C., Patel, N. R., Takano, J., Easterling, L., Scanlon, M., Musa, N., et al. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000094228.90557.85 · Cited by 311
The use of cuffed versus uncuffed endotracheal tubes in pediatric intensive care
Newth, C. J. L., Rachman, B., Patel, N., & Hammer, J. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2003.12.018 · Cited by 278
The Feasibility of Ultrasound to Assess Subglottic Diameter
Lakhal, K., Delplace, X., Cottier, J., Tranquart, F., Sauvagnac, X., Mercier, C., Fusciardi, J., & Laffon, M. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000260136.53694.fe · Cited by 192 · cited 3×
“Recent reports suggest that the diameter of the subglottic upper airway can be determined by ultrasonography in healthy young adults and pediatric patients.(11,12) However, the extent to which ultrasonography can predict optimal ETT size in pediatric patients remains to be determined.”
BackgroundPediatric Formulas for the Anesthesiologist
Cole, F. (1957) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1957.04030070084009 · Cited by 117 · cited 1×
“Age-based formulas, such as those of Cole and Motoyama, have been used to estimate optimal ETT size for more than half a century.(6,7) Predictive formulas for appropriate ETT size have also been based on patient weight and height.”
MethodSalgo, B., Schmitz, A., Henze, G., Stutz, K., Dullenkopf, A., Neff, S., Gerber, A. C., & Weiß, M. (2006) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01003.x · Cited by 94
Incidence of aspiration with endotracheal tubes in children
Browning, D. H., & Graves, S. A. (1983) · The Journal of Pediatrics · doi:10.1016/s0022-3476(83)80191-7 · Cited by 86
Cited by
Ultrasonography in the management of the airway
KRISTENSEN, M. S. (2011) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2011.02518.x · Cited by 230
Kristensen, M. S., Teoh, W. H., Graumann, O., & Laursen, C. B. (2014) · Insights into Imaging · doi:10.1007/s13244-014-0309-5 · Cited by 179
“In children [50] and young adults, ultrasound can reliably”
Background
Metadata
- Authors
- Shibasaki, M., Nakajima, Y., Ishii, S., Shimizu, F., Shime, N., & Sessler, D. I.
- Venue
- Anesthesiology
- Published
- 2010-10-01
- Volume
- 113
- Issue
- 4
- Pages
- 819-824
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2019672635
- Cited by
- 236
- References
- 8
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.