The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Extubation failure in pediatric intensive care: A multiple-center study of risk factors and outcomes
Abstract
OBJECTIVE: To determine a contemporary failed extubation rate, risk factors, and consequences of extubation failure in pediatric intensive care units (PICUs). Three hypotheses were investigated: a) Extubation failure is in part disease specific; b) preexisting respiratory conditions predispose to extubation failure; and c) admission acuity scoring does not affect extubation failure. DESIGN: Twelve-month prospective, observational, clinical study. SETTING: Sixteen diverse PICUs in the United States. PATIENTS: Patients were 2,794 patients from the newborn period to 18 yrs of age experiencing a planned extubation trial. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A descriptive statistical analysis was performed, and outcome differences of the failed extubation population were determined. The extubation failure rate was 6.2% (174 of 2,794; 95% confidence interval, 5.3-7.1). Patient features associated with extubation failure (p <.05) included age < or =24 months; dysgenetic condition; syndromic condition; chronic respiratory disorder; chronic neurologic condition; medical or surgical airway condition; chronic noninvasive positive pressure ventilation; the need to replace the endotracheal tube on admission to the PICU; and the use of racemic epinephrine, steroids, helium-oxygen therapy (heliox), or noninvasive positive pressure ventilation within 24 hrs of extubation. Patients failing extubation had longer pre-extubation intubation time (failed, 148.7 hrs, SD +/- 207.8 vs. success, 107.9 hrs, SD +/- 171.3; p <.001), longer PICU length of stay (17.5 days, SD +/- 15.6 vs. 7.6 days, SD +/- 11.1; p <.001), and a higher mortality rate than patients not failing extubation (4.0% vs. 0.8%; p <.001). Failure was found to be in part disease specific, and preexisting respiratory conditions were found to predispose to failure whereas admission acuity did not. CONCLUSION: A variety of patient features are associated with an increase in extubation failure rate, and serious outcome consequences characterize the extubation failure population in PICUs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Failed Extubation on the Outcome of Mechanical Ventilation
Epstein, S. K., Ciubotaru, R. L., & Wong, J. B. (1997) · Chest · doi:10.1378/chest.112.1.186 · Cited by 892
EPSTEIN, S. K., & CIUBOTARU, R. L. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.2.9711045 · Cited by 598
Implications of Extubation Delay in Brain-Injured Patients Meeting Standard Weaning Criteria
COPLIN, W. M., PIERSON, D. J., COOLEY, K. D., NEWELL, D. W., & RUBENFELD, G. D. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9905102 · Cited by 544
Khamiees, M., Raju, P., DeGirolamo, A., Amoateng-Adjepong, Y., & Manthous, C. A. (2001) · Chest · doi:10.1378/chest.120.4.1262 · Cited by 466
Epstein, S. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1268-8 · Cited by 288
Cuffed endotracheal tubes in pediatric intensive care
Deakers, T. W., Reynolds, G., Stretton, M., & Newth, C. J. L. (1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70121-0 · Cited by 239
Self-citationEffect of Unplanned Extubation on Outcome of Mechanical Ventilation
EPSTEIN, S. K., NEVINS, M. L., & CHUNG, J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.6.9908068 · Cited by 219
Spinal Muscular Atrophy Type 1
Bach, J. R., Niranjan, V., & Weaver, B. (2000) · Chest · doi:10.1378/chest.117.4.1100 · Cited by 209
Fiser, D. H., Tilford, J. M., & Roberson, P. K. (2000) · Critical Care Medicine · doi:10.1097/00003246-200004000-00043 · Cited by 206
Extubation Failure in a Large Pediatric ICU Population
Edmunds, S. M., Weiss, I. K., & Harrison, R. E. (2001) · CHEST Journal · doi:10.1378/chest.119.3.897 · Cited by 143
Cited by
Badruddin, S. S., Clayton, J. A., McKee, B. P., Slain, K. N., Rotta, A. T., Malay, S., & Shein, S. L. (2021) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000002581 · Cited by 18
Metadata
- Authors
- Kurachek, S. C., Newth, C. J., Quasney, M. W., Rice, T., Sachdeva, R. C., Patel, N. R., Takano, J., Easterling, L., Scanlon, M., Musa, N., Brilli, R. J., Wells, D., Park, G. S., Penfil, S., Bysani, K. G., Nares, M. A., Lowrie, L., Billow, M., Chiochetti, E., & Lindgren, B.
- Venue
- Critical Care Medicine
- Published
- 2003-11
- Volume
- 31
- Issue
- 11
- Pages
- 2657-2664
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2083377182
- Cited by
- 311
- References
- 19
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extubation failure in pediatric intensive care: A multiple-center study of risk factors and outcomes. https://app.cochat.ai/papers/10.1097/01.ccm.0000094228.90557.85
- The paper
- Kurachek, S. C., Newth, C. J., Quasney, M. W., Rice, T., Sachdeva, R. C., Patel, N. R., Takano, J., Easterling, L., Scanlon, M., Musa, N., Brilli, R. J., Wells, D., Park, G. S., Penfil, S., Bysani, K. G., Nares, M. A., Lowrie, L., Billow, M., Chiochetti, E., & Lindgren, B. (2003). Extubation failure in pediatric intensive care: A multiple-center study of risk factors and outcomes. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000094228.90557.85
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.