CoChat

Sitting Posture Decreases Collapsibility of the Passive Pharynx in Anesthetized Paralyzed Patients with Obstructive Sleep Apnea

Tagaito, Yugo, Isono, Shiroh, Tanaka, Atsuko, Ishikawa, Teruhiko, Nishino, Takashi · 2010 · Anesthesiology
Cited by 77

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Obstructive sleep apnea (OSA) is an independent risk factor for difficult and/or impossible mask ventilation during anesthesia induction. Postural change from supine to sitting improves nocturnal breathing in patients with OSA. The purpose of this study was to evaluate the effect of patient position on collapsibility of the pharyngeal airway in anesthetized and paralyzed patients with OSA. The authors tested the hypothesis that the passive pharynx is structurally less collapsible during sitting than during supine posture. Method: Total muscle paralysis was induced with general anesthesia in nine patients with OSA, eliminating neuromuscular factors contributing to pharyngeal patency. The cross-sectional area of the pharynx was measured endoscopically at different static airway pressures. Comparison of static pressure-area plots between the supine and sitting (62° head-up) allowed assessment of the postural differences of the mechanical properties of the pharynx. Results: : Maximum cross-sectional area was greater during sitting than during supine posture at both retropalatal (median (10th-90th percentile): 1.91 (1.52-3.40) versus 1.25 (0.65-1.97) cm) and retroglossal (2.42 (1.72-3.84) versus 1.75 (0.47-2.35) cm) airways. Closing pressure of the passive pharynx was significantly lower during sitting than supine posture. Differences of the closing pressures between the postures are 5.89 (3.73-11.6) and 6.74 (4.16-9.87) cm H2O, at retropalatal and retroglossal airways, respectively, and did not differ between the pharyngeal segments. Conclusions: Postural change from supine to sitting significantly improves collapsibility of pharyngeal airway in anesthetized and paralyzed patients with OSA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e3181f1b834

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 77

Metadata

Authors
Tagaito, Y., Isono, S., Tanaka, A., Ishikawa, T., & Nishino, T.
Venue
Anesthesiology
Published
2010-10-01
Volume
113
Issue
4
Pages
812-818
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2012440443
Cited by
77
References
3
FWCI
2.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sitting Posture Decreases Collapsibility of the Passive Pharynx in Anesthetized Paralyzed Patients with Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1097/aln.0b013e3181f1b834
The paper
Tagaito, Y., Isono, S., Tanaka, A., Ishikawa, T., & Nishino, T. (2010). Sitting Posture Decreases Collapsibility of the Passive Pharynx in Anesthetized Paralyzed Patients with Obstructive Sleep Apnea. Anesthesiology. https://doi.org/10.1097/aln.0b013e3181f1b834

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.