CoChat

A Decision Rule for Diagnostic Testing in Obstructive Sleep Apnea

Tsai, Willis H., Remmers, John E., Brant, Rollin, Flemons, W. Ward, Davies, Jan, Macarthur, Colin · 2003 · American Journal of Respiratory and Critical Care Medicine

The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.

Abstract

Obstructive sleep apnea (OSA) is traditionally diagnosed using overnight polysomnography. Decision rules may provide an alternative to polysomnography. A consecutive series of patients referred to a tertiary sleep center underwent prospective evaluation with the upper airway physical examination protocol, followed by determination of the respiratory disturbance index using a portable monitor. Seventy-five patients were evaluated with the upper airway physical examination protocol. Historic predictors included age, snoring, witnessed apneas, and hypertension. Physical examination–based predictors included body mass index, neck circumference, mandibular protrusion, thyro–rami distance, sterno–mental distance, sterno–mental displacement, thyro–mental displacement, cricomental space, pharyngeal grade, Sampsoon-Young classification, and over-bite. A decision rule was developed using three predictors: a cricomental space of 1.5 cm or less, a pharyngeal grade of more than II, and the presence of overbite. In patients with all three predictors (17%), the decision rule had a positive predictive value of 95% (95% confidence interval [CI], 75–100%) and a negative predictive value of 49% (95% CI, 35–63%). A cricomental space of more than 1.5 cm (27% of patients) excluded OSA (negative predictive value of 100%, 95% CI, 75–100%). Comparable performance was obtained in a validation sample of 50 patients referred for diagnostic testing. This decision rule provides a simple, reliable, and accurate method of identifying a subset patients with, and perhaps more importantly, without OSA.

Overview

Integrity signals

Registry

Crossref · 10.1164/rccm.200112-110oc

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Research works printed but not linked: 2

  1. 1994, Am J Respir Crit Care Med, 150, 735, 10.1164/ajrccm.150.3.8087345 · DOI · Paper page
  2. 1993, JAMA, 269, 1127, 10.1001/jama.1993.03500090063034 · doi:10.1001/jama.1993.03500090063034 · Paper page

Cited by

See all 189

Metadata

Authors
Tsai, W. H., Remmers, J. E., Brant, R., Flemons, W. W., Davies, J., & Macarthur, C.
Affiliations
University of Calgary (CA)
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2003-05
Volume
167
Issue
10
Pages
1427-1432
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2133285255
Cited by
189
References
20
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2022: 7 · 2021: 3 · 2020: 3 · 2019: 6 · 2018: 6 · 2017: 14 · 2016: 10 · 2015: 12 · 2014: 7 · 2013: 18 · 2012: 8
FWCI
5.75
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Library and Archives Canada (Government of Canada) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
Keywords
obstructive sleep apnea, diagnostic decision rules, overbite, portable monitoring, respiratory disturbance index, polysomnography alternative, positive predictive value, negative predictive value
MeSH terms
Adult, Aged, Analysis of Variance, Anthropometry, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Pharynx, Physical Examination, Predictive Value of Tests, Prospective Studies, Risk Factors, Sampling Studies, Sensitivity and Specificity, Severity of Illness Index, Reproducibility of Results, Polysomnography, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Decision Rule for Diagnostic Testing in Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.200112-110oc
The paper
Tsai, W. H., Remmers, J. E., Brant, R., Flemons, W. W., Davies, J., & Macarthur, C. (2003). A Decision Rule for Diagnostic Testing in Obstructive Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200112-110oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.