First-line Therapy with Coagulation Factor Concentrates Combined with Point-of-Care Coagulation Testing Is Associated with Decreased Allogeneic Blood Transfusion in Cardiovascular Surgery: A Retrospective, Single-center Cohort Study
Open accessAbstract
Introduction: Blood transfusion is associated with increased morbidity and mortality. We developed and implemented an algorithm for coagulation management in cardiovascular surgery based on first-line administration of coagulation factor concentrates combined with point-of-care thromboelastometry/impedance aggregometry. Methods: In a retrospective cohort study including 3,865 patients, we analyzed the incidence of intraoperative allogeneic blood transfusions (primary endpoints) before and after algorithm implementation. Results: Following algorithm implementation, the incidence of any allogeneic blood transfusion (52.5 vs. 42.2%; P < 0.0001), packed red blood cells (49.7 vs. 40.4%; P < 0.0001), and fresh frozen plasma (19.4 vs. 1.1%; P < 0.0001) decreased, whereas platelet transfusion increased (10.1 vs. 13.0%; P = 0.0041). Yearly transfusion of packed red blood cells (3,276 vs. 2,959 units; P < 0.0001) and fresh frozen plasma (1986 vs. 102 units; P < 0.0001) decreased, as did the median number of packed red blood cells and fresh frozen plasma per patient. The incidence of fibrinogen concentrate (3.73 vs. 10.01%; P < 0.0001) and prothrombin complex concentrate administration (4.42 vs. 8.9%; P < 0.0001) increased, as did their amount administered per year (179 vs. 702 g; P = 0.0008 and 162 × 10³ U vs. 388 × 10³ U; P = 0.0184, respectively). Despite a switch from aprotinin to tranexamic acid, an increase in use of dual antiplatelet therapy (2.7 vs. 13.7%; P < 0.0001), patients' age, proportion of females, emergency cases, and more complex surgery, the incidence of massive transfusion [(≥10 units packed red blood cells), (2.5 vs. 1.26%; P = 0.0057)] and unplanned reexploration (4.19 vs. 2.24%; P = 0.0007) decreased. Composite thrombotic/thromboembolic events (3.19 vs. 1.77%; P = 0.0115) decreased, but in-hospital mortality did not change (5.24 vs. 5.22%; P = 0.98). Conclusions: First-line administration of coagulation factor concentrates combined with point-of-care testing was associated with decreased incidence of blood transfusion and thrombotic/thromboembolic events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murphy, G. J., Reeves, B. C., Rogers, C. A., Rizvi, S. I. A., Culliford, L., & Angelini, G. D. (2007) · Circulation · doi:10.1161/circulationaha.107.698977 · Cited by 1,371 · cited 1×
“Furthermore, blood transfusion is associated with prolonged hospital stay as well as increased hospital costs.(3) Smaller studies suggest that implementation of point-ofcare (POC) coagulation tests coupled to algorithm-based management decreases transfusion requirements in cardiac surgery.”
BackgroundPathophysiology and Treatment of Coagulopathy in Massive Hemorrhage and Hemodilution
Bolliger, D., Görlinger, K., Tanaka, K. A., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181f22b5a · Cited by 325
Self-citationNuttall, G. A., Oliver, W. C., Santrach, P. J., Bryant, S., Dearani, J. A., Schaff, H. V., & Ereth, M. H. (2001) · Anesthesiology · doi:10.1097/00000542-200105000-00014 · Cited by 285
Westbrook, A. J., Olsen, J., Bailey, M., Bates, J., Scully, M., & Salamonsen, R. F. (2009) · Heart, Lung and Circulation · doi:10.1016/j.hlc.2008.08.016 · Cited by 121 · cited 1×
“In fact, only Westbrook et al.(18) used a method for”
MethodPlatelet function testing and risk of bleeding complications
Ferreiro, J. L., Sibbing, D., & Angiolillo, D. (2010) · Thrombosis and Haemostasis · doi:10.1160/th09-11-0799 · Cited by 104
Prediction and management of bleeding in cardiac surgery
DESPOTIS, G., AVIDAN, M., & EBY, C. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03412.x · Cited by 99
Cited by
TEG and ROTEM: Technology and clinical applications
Whiting, D., & DiNardo, J. A. (2014) · American Journal of Hematology · doi:10.1002/ajh.23599 · Cited by 688
Weber, C. F., Görlinger, K., Meininger, D., Herrmann, E., Bingold, T., Moritz, A., Cohn, L. H., & Zacharowski, K. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318264c644 · Cited by 625
Self-citation
Metadata
- Authors
- Görlinger, K., Dirkmann, D., Hanke, A. A., Kamler, M., Kottenberg, E., Thielmann, M., Jakob, H., & Peters, J.
- Venue
- Anesthesiology
- Published
- 2011-12-01
- Volume
- 115
- Issue
- 6
- Pages
- 1179-1191
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1999666547
- Cited by
- 426
- References
- 6
- FWCI
- 26.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First-line Therapy with Coagulation Factor Concentrates Combined with Point-of-Care Coagulation Testing Is Associated with Decreased Allogeneic Blood Transfusion in Cardiovascular Surgery: A Retrospective, Single-center Cohort Study. https://app.cochat.ai/papers/10.1097/aln.0b013e31823497dd
- The paper
- Görlinger, K., Dirkmann, D., Hanke, A. A., Kamler, M., Kottenberg, E., Thielmann, M., Jakob, H., & Peters, J. (2011). First-line Therapy with Coagulation Factor Concentrates Combined with Point-of-Care Coagulation Testing Is Associated with Decreased Allogeneic Blood Transfusion in Cardiovascular Surgery: A Retrospective, Single-center Cohort Study. Anesthesiology. https://doi.org/10.1097/aln.0b013e31823497dd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.