The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation: A Comparison of Three Cerebral Oximetry Technologies
Open accessAbstract
Background: Cerebral oximetry is a noninvasive technology using near-infrared spectroscopy (NIRS) to estimate regional cerebral oxygen saturation. Although NIRS cerebral oximetry is being increasingly used in many clinical settings, interdevice technologic differences suggest potential variation in the ability to accurately acquire brain oxygenation signals. The primary objective of this study was to determine if NIRS-derived regional cerebral oxygen saturation measurements accurately account for oxygen saturation contamination from extracranial tissue. Methods: Twelve healthy volunteers had each of three NIRS devices (FORE-SIGHT [CAS Medical Systems Inc; Brandford, CT], INVOS 5100C-PB [Covidien; Boulder, CO], and EQUANOX Classic 7600 [Nonin Medical Inc; Plymouth, MN]) randomly applied to the forehead. After this, a circumferential pneumatic head cuff was positioned such that when inflated, hypoxia-ischemia would be produced in the extracranial scalp tissue beneath the NIRS cerebral oximeters. Comparisons among the three devices were made of the NIRS measurements before and following hypoxia-ischemia produced in the scalp tissue with inflation of the head cuff. Results: The induction of extracranial hypoxia-ischemia resulted in a significant reduction in regional cerebral oxygen saturation measurements in all three NIRS devices studied. At 5 min postinflation of the pneumatic head cuff, the INVOS demonstrated a 16.6 ± 9.6% (mean ± SD) decrease from its baseline (P = 0.0001), the FORE-SIGHT an 11.8 ± 5.3% decrease from its baseline (P < 0.0001), and the EQUANOX a 6.8 ± 6.0% reduction from baseline (P = 0.0025). Conclusions: Extracranial contamination appears to significantly affect NIRS measurements of cerebral oxygen saturation. Although the clinical implications of these apparent inaccuracies require further study, they suggest that the oxygen saturation measurements provided by cerebral oximetry do not solely reflect that of the brain alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple comparisons among means
Dunn, O. J. (1961) · Journal of the American Statistical Association · doi:10.1080/01621459.1961.10482090 · Cited by 5,006
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Monitoring Brain Oxygen Saturation During Coronary Bypass Surgery: A Randomized, Prospective Study
Murkin, J. M., Adams, S. J., Novick, R. J., Quantz, M., Bainbridge, D., Iglesias, I., Cleland, A., Schaefer, B., Irwin, B., & Fox, S. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000246814.29362.f4 · Cited by 813
Slater, J. P., Guarino, T., Stack, J., Vinod, K., Bustami, R. T., Brown, J. M., Rodriguez, A. L., Magovern, C. J., Zaubler, T., Freundlich, K., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.08.070 · Cited by 626
Arterial and Venous Contributions to Near-infrared Cerebral Oximetry
Watzman, H. M., Kurth, C. D., Montenegro, L. M., Rome, J., Steven, J. M., & Nicolson, S. C. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00012 · Cited by 451
Brady, K., Joshi, B., Zweifel, C., Smielewski, P., Czosnyka, M., Easley, R. B., & Hogue, C. W. (2010) · Stroke · doi:10.1161/strokeaha.109.575159 · Cited by 360
Spectrophotometry of Intracellular Respiratory Pigments
Chance, B. (1954) · Science · doi:10.1126/science.120.3124.767 · Cited by 352
Yao, F.-S. F., Tseng, C.-C. A., Ho, C.-Y. A., Levin, S. K., & Illner, P. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.007 · Cited by 351
A Proposed Algorithm for the Intraoperative Use of Cerebral Near-Infrared Spectroscopy
Denault, A. Y., Deschamps, A., & Murkin, J. M. (2007) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253207311685 · Cited by 329
Preoperative Cerebral Oxygen Saturation and Clinical Outcomes in Cardiac Surgery
Heringlake, M., Garbers, C., Käbler, J.-H., Anderson, I., Heinze, H., Schön, J., Berger, K.-U., Dibbelt, L., Sievers, H.-H., & Hanke, T. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3181fef34e · Cited by 303
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Zheng, F., Sheinberg, R., Yee, M.-S., Ono, M., Zheng, Y., & Hogue, C. W. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318277a255 · Cited by 299
Weber, F., & Scoones, G. P. (2019) · Pediatric Anesthesia · doi:10.1111/pan.13726 · Cited by 53
Fellahi, J.-L., Butin, G., Fischer, M.-O., Zamparini, G., Gérard, J.-L., & Hanouz, J.-L. (2013) · Journal of Critical Care · doi:10.1016/j.jcrc.2013.05.004 · Cited by 42
Metadata
- Authors
- Davie, S. N., & Grocott, H. P.
- Venue
- Anesthesiology
- Published
- 2012-04-01
- Volume
- 116
- Issue
- 4
- Pages
- 834-840
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2112299151
- Cited by
- 383
- References
- 18
- FWCI
- 28.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation: A Comparison of Three Cerebral Oximetry Technologies. https://app.cochat.ai/papers/10.1097/aln.0b013e31824c00d7
- The paper
- Davie, S. N., & Grocott, H. P. (2012). Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation: A Comparison of Three Cerebral Oximetry Technologies. Anesthesiology. https://doi.org/10.1097/aln.0b013e31824c00d7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.