Cited by 57Congenital Heart Disease StudiesPrenatal Screening and DiagnosticsCongenital heart defects research

Fetal cardiac axis and congenital heart defects in early gestation

Sinkovskaya, Elena S., Chaoui, Rabih, Karl, Katrin, Andreeva, Elena, Zhuchenko, Ludmila, Abuhamad, Alfred Z.·2015·Obstetrics & Gynecology

Abstract

OBJECTIVE: To investigate the association between cardiac axis and fetal congenital heart defects to demonstrate the potential clinical applicability of cardiac axis measurement for detection of congenital heart defect in early gestation. METHODS: This case-control study was undertaken in three tertiary centers with expertise in fetal imaging in early gestation. Fetal cardiac axis was evaluated between 11 0/7 and 14 6/7 weeks of gestation in 197 fetuses with confirmed congenital heart defects. A control group was selected by matching each fetus with a congenital heart defect with two fetuses in the control group with similar crown-rump length (± 5 mm) and date of study (± 2 months). Cardiac axis was measured on the four-chamber view as the angle between the line that traces the long axis of the heart and the line that bisects the thorax in an anteroposterior direction. RESULTS: In the control group, mean cardiac axis was 44.5 ± 7.4°. The cardiac axis did not significantly change in early pregnancy. In the congenital heart defect group, 25.9% of fetuses had cardiac axis measurements within normal limits. In 74.1%, the cardiac axis was abnormal including 110 fetuses in the case group with left deviation (cardiac axis > 97.5th percentile), 19 fetuses in the case group with right deviation (cardiac axis < 2.5th percentile), and 17 fetuses in the case group with nonidentifiable cardiac axis. The performance of cardiac axis measurement in detection of major congenital heart defect was significantly better than enlarged nuchal translucency, tricuspid regurgitation, or reversed A-wave in ductus venosus used alone or in combination. CONCLUSION: Abnormal cardiac axis is present in two-thirds of fetuses with congenital heart defect in early gestation. Adding cardiac axis assessment to the nuchal translucency measurement is helpful in defining a population at risk for fetal congenital heart defect.

Integrity signals

Registry

Crossref · 10.1097/aog.0000000000000608

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The cardiac axis was abnormal in 74.1% of fetuses with congenital heart disease.

    “The cardiac axis is an important parameter for cardiac defects, as results from a multicenter study showed that it was abnormal in 74.1% of fetuses with congenital heart disease [46].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Sinkovskaya, E. S., Chaoui, R., Karl, K., Andreeva, E., Zhuchenko, L., & Abuhamad, A. Z.
Affiliations
Eastern Virginia Medical School (US)
Venue
Obstetrics & Gynecology
Published
2015-02
Volume
125
Issue
2
Pages
453-460
ISSN
0029-7844 (ISSN-L)
OpenAlex
W2334630058
Cited by
57
References
1
Citations by year
2026: 2 · 2025: 3 · 2024: 6 · 2023: 8 · 2022: 3 · 2021: 2 · 2020: 6 · 2019: 4 · 2018: 5 · 2017: 10 · 2016: 4 · 2015: 4
FWCI
6.03
Type
journal article
Language
en
Open access
closed
Locations
  • Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Congenital heart defects research
Keywords
congenital heart disease, early pregnancy, second-trimester screening, nuchal translucency, tricuspid regurgitation, ductus venosus, fetal echocardiography, risk stratification
MeSH terms
Adolescent, Adult, Female, Fetal Heart, Heart Defects, Congenital, Humans, Middle Aged, Pregnancy, Pregnancy Trimester, First, Case-Control Studies, Ultrasonography, Prenatal, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review