Three-Dimensional Power Doppler Ultrasonography for Diagnosing Abnormally Invasive Placenta and Quantifying the Risk
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To test an objective ultrasound marker for diagnosing the presence and severity of abnormally invasive placenta. METHODS: Women at risk of abnormally invasive placenta underwent a three-dimensional power Doppler ultrasound scan. The volumes were examined offline by a blinded observer. The largest area of confluent three-dimensional power Doppler signal (Area of Confluence [Acon], cm) at the uteroplacental interface was measured and compared in women subsequently diagnosed with abnormally invasive placenta and women in a control group who did not have abnormally invasive placenta. Receiver operating characteristic curves were plotted for prediction of abnormally invasive placenta and abnormally invasive placenta requiring cesarean hysterectomy. RESULTS: Ninety-three women were recruited. Results were available for 89. Abnormally invasive placenta was clinically diagnosed in 42 women; 36 required hysterectomy and had abnormally invasive placenta confirmed histopathologically. Median and interquartile range for Acon was greater for abnormally invasive placenta (44.2 [31.4-61.7] cm) compared with women in the control group (4.5 cm [2.9-6.6], P<.001) and even greater in the 36 requiring hysterectomy (46.6 cm [37.2-72.6], P<.001). Acon rose with histopathologic diagnosis: focal accreta (32.2 cm [17.2-57.3]), accreta (59.6 cm [40.1-89.9]), and percreta (46.6 cm [37.5-71.5]; P<.001 analysis of variance for linear trend). Receiver operating characteristic analysis for prediction of abnormally invasive placenta revealed that with an Acon of 12.4 cm or greater, 100% sensitivity (95% confidence interval [CI] 91.6-100) could be obtained with 92% specificity (95% CI 79.6-97.6); area under the curve is 0.99 (95% CI 0.94-1.0). For prediction of abnormally invasive placenta requiring hysterectomy, 100% sensitivity (95% CI 90.3-100) can be obtained with an Acon of 17.4 cm or greater with 87% specificity (95% CI 74.7-94.5; area under the curve 0.98 [0.93-1.0]). CONCLUSION: The marker Acon provides a quantitative means for diagnosing abnormally invasive placenta and assessing severity. If further validated, subjectivity could be eliminated from the diagnosis of abnormally invasive placenta. LEVEL OF EVIDENCE: II.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eller, A. G., Bennett, M. A., Sharshiner, M., Masheter, C., Soisson, A. P., Dodson, M., & Silver, R. M. (2011) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3182051db2 · Cited by 556 · cited 2×
“Although in many screening situations this would be too high, it is probably acceptable if it ensures no cases are missed in a condition in which antenatal diagnosis has been shown to significantly decrease maternal morbidity.(2,3) The technique itself also has weaknesses and unknown factors.”
BackgroundBelfort, M. A. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.09.013 · Cited by 484
Committee Opinion No. 529: Placenta Accreta
(2012) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e318262e340 · Cited by 369
Solheim, K. N., Esakoff, T. F., Little, S. E., Cheng, Y. W., Sparks, T. N., & Caughey, A. B. (2011) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2011.553695 · Cited by 320 · cited 1×
“In summary we report a new, quantitative ultrasound technique enabling reliable prenatal identification of abnormally invasive placenta, a condition in which prenatal diagnosis has been shown to reduce the high maternal mortality and morbidity.(25) The application of existing image analysis tools to automate calculati…”
MethodCritical analysis of risk factors and outcome of placenta previa
Rosenberg, T., Pariente, G., Sergienko, R., Wiznitzer, A., & Sheiner, E. (2011) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-010-1598-7 · Cited by 259
Shunting the intervillous space: new concepts in human uteroplacental vascularization
Schaaps, J.-P., Tsatsaris, V., Goffin, F., Brichant, J.-F., Delbecque, K., Tebache, M., Collignon, L., Retz, M. C., & Foidart, J.-M. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.06.066 · Cited by 142
Dilauro, M. D., Dason, S., & Athreya, S. (2012) · Clinical Radiology · doi:10.1016/j.crad.2011.10.031 · Cited by 121
Maternal and Fetal Outcomes in Placenta Accreta After Institution of Team-Managed Care
Al-Khan, A., Gupta, V., Illsley, N. P., Mannion, C., Koenig, C., Bogomol, A., Alvarez, M., & Zamudio, S. (2014) · Reproductive Sciences · doi:10.1177/1933719113512528 · Cited by 119 · cited 3×
“Although in many screening situations this would be too high, it is probably acceptable if it ensures no cases are missed in a condition in which antenatal diagnosis has been shown to significantly decrease maternal morbidity.(2,3) The technique itself also has weaknesses and unknown factors.”
BackgroundSelf-citationCollins, S. L., Stevenson, G. N., Noble, J. A., Impey, L., & Welsh, A. W. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10122 · Cited by 52
Self-citationTeare, J., Evans, E., Belli, A., & Wendler, R. (2014) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2013.11.002 · Cited by 33
Cited by
Jauniaux, E., Collins, S., & Burton, G. J. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.05.067 · Cited by 775
“Invasion into these shunts is the proposed cause of the large areas of abnormal vascular confluence seen with 3-dimensional power Doppler imaging in cases of PP.76 In addition, the vasculature characteristics of the placental bed may vary in PAS depending on the position of the placenta inside the uterine cavity, whet…”
BackgroundInfluentialSelf-citationFIGO classification for the clinical diagnosis of placenta accreta spectrum disorders,
Jauniaux, E., Ayres‐de‐Campos, D., Langhoff‐Roos, J., Fox, K. A., Collins, S., & Panel, F. P. A. D. A. M. E. C. (2019) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.12761 · Cited by 668
Self-citationFIGO consensus guidelines on placenta accreta spectrum disorders: Epidemiology,
Jauniaux, E., Chantraine, F., Silver, R. M., Langhoff‐Roos, J., & Panel, F. T. F. P. A. D. A. M. E. C. (2018) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.12407 · Cited by 498
Jauniaux, E., Collins, S. L., Jurkovic, D., & Burton, G. J. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.07.044 · Cited by 208
Self-citationMillischer, A., Salomon, L., Porcher, R., Brasseur‐Daudruy, M., Gourdier, A., Hornoy, P., Silvera, S., Loisel, D., Tsatsaris, V, Delorme, B., et al. (2017) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.14164 · Cited by 43
Metadata
- Authors
- Collins, S. L., Stevenson, G. N., Al-Khan, A., Illsley, N. P., Impey, L., Pappas, L., & Zamudio, S.
- Venue
- Obstetrics & Gynecology
- Published
- 2015-09
- Volume
- 126
- Issue
- 3
- Pages
- 645-653
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2315983265
- Cited by
- 113
- References
- 11
- FWCI
- 9.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional Power Doppler Ultrasonography for Diagnosing Abnormally Invasive Placenta and Quantifying the Risk. https://app.cochat.ai/papers/10.1097/aog.0000000000000962
- The paper
- Collins, S. L., Stevenson, G. N., Al-Khan, A., Illsley, N. P., Impey, L., Pappas, L., & Zamudio, S. (2015). Three-Dimensional Power Doppler Ultrasonography for Diagnosing Abnormally Invasive Placenta and Quantifying the Risk. Obstetrics & Gynecology. https://doi.org/10.1097/aog.0000000000000962
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.