CoChat

Three-Dimensional Power Doppler Ultrasonography for Diagnosing Abnormally Invasive Placenta and Quantifying the Risk

Open access
Collins, Sally L., Stevenson, Gordon N., Al-Khan, Abdulla, Illsley, Nicholas P., Impey, Lawrence, Pappas, Leigh, Zamudio, Stacy · 2015 · Obstetrics & Gynecology
Cited by 113

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To test an objective ultrasound marker for diagnosing the presence and severity of abnormally invasive placenta. METHODS: Women at risk of abnormally invasive placenta underwent a three-dimensional power Doppler ultrasound scan. The volumes were examined offline by a blinded observer. The largest area of confluent three-dimensional power Doppler signal (Area of Confluence [Acon], cm) at the uteroplacental interface was measured and compared in women subsequently diagnosed with abnormally invasive placenta and women in a control group who did not have abnormally invasive placenta. Receiver operating characteristic curves were plotted for prediction of abnormally invasive placenta and abnormally invasive placenta requiring cesarean hysterectomy. RESULTS: Ninety-three women were recruited. Results were available for 89. Abnormally invasive placenta was clinically diagnosed in 42 women; 36 required hysterectomy and had abnormally invasive placenta confirmed histopathologically. Median and interquartile range for Acon was greater for abnormally invasive placenta (44.2 [31.4-61.7] cm) compared with women in the control group (4.5 cm [2.9-6.6], P<.001) and even greater in the 36 requiring hysterectomy (46.6 cm [37.2-72.6], P<.001). Acon rose with histopathologic diagnosis: focal accreta (32.2 cm [17.2-57.3]), accreta (59.6 cm [40.1-89.9]), and percreta (46.6 cm [37.5-71.5]; P<.001 analysis of variance for linear trend). Receiver operating characteristic analysis for prediction of abnormally invasive placenta revealed that with an Acon of 12.4 cm or greater, 100% sensitivity (95% confidence interval [CI] 91.6-100) could be obtained with 92% specificity (95% CI 79.6-97.6); area under the curve is 0.99 (95% CI 0.94-1.0). For prediction of abnormally invasive placenta requiring hysterectomy, 100% sensitivity (95% CI 90.3-100) can be obtained with an Acon of 17.4 cm or greater with 87% specificity (95% CI 74.7-94.5; area under the curve 0.98 [0.93-1.0]). CONCLUSION: The marker Acon provides a quantitative means for diagnosing abnormally invasive placenta and assessing severity. If further validated, subjectivity could be eliminated from the diagnosis of abnormally invasive placenta. LEVEL OF EVIDENCE: II.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aog.0000000000000962

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 113

Metadata

Authors
Collins, S. L., Stevenson, G. N., Al-Khan, A., Illsley, N. P., Impey, L., Pappas, L., & Zamudio, S.
Venue
Obstetrics & Gynecology
Published
2015-09
Volume
126
Issue
3
Pages
645-653
ISSN
0029-7844 (ISSN-L)
OpenAlex
W2315983265
Cited by
113
References
11
FWCI
9.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-Dimensional Power Doppler Ultrasonography for Diagnosing Abnormally Invasive Placenta and Quantifying the Risk. https://app.cochat.ai/papers/10.1097/aog.0000000000000962
The paper
Collins, S. L., Stevenson, G. N., Al-Khan, A., Illsley, N. P., Impey, L., Pappas, L., & Zamudio, S. (2015). Three-Dimensional Power Doppler Ultrasonography for Diagnosing Abnormally Invasive Placenta and Quantifying the Risk. Obstetrics & Gynecology. https://doi.org/10.1097/aog.0000000000000962

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.