CoChat

The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index, and 1 are not checked yet; none of the 51 sources its claims cite is checked for support yet.

Hearing Aid Noise Reduction Lowers the Sustained Listening Effort During Continuous Speech in Noise—A Combined Pupillometry and EEG Study

Open access
Fiedler, Lorenz, Seifi Ala, Tirdad, Graversen, Carina, Alickovic, Emina, Lunner, Thomas, Wendt, Dorothea · 2021 · Ear & Hearing

Abstract

Objectives: The investigation of auditory cognitive processes recently moved from strictly controlled, trial-based paradigms toward the presentation of continuous speech. This also allows the investigation of listening effort on larger time scales (i.e., sustained listening effort). Here, we investigated the modulation of sustained listening effort by a noise reduction algorithm as applied in hearing aids in a listening scenario with noisy continuous speech. The investigated directional noise reduction algorithm mainly suppresses noise from the background. Design: We recorded the pupil size and the EEG in 22 participants with hearing loss who listened to audio news clips in the presence of background multi-talker babble noise. We estimated how noise reduction (off, on) and signal-to-noise ratio (SNR; +3 dB, +8 dB) affect pupil size and the power in the parietal EEG alpha band (i.e., parietal alpha power) as well as the behavioral performance. Results: Our results show that noise reduction reduces pupil size, while there was no significant effect of the SNR. It is important to note that we found interactions of SNR and noise reduction, which suggested that noise reduction reduces pupil size predominantly under the lower SNR. Parietal alpha power showed a similar yet nonsignificant pattern, with increased power under easier conditions. In line with the participants’ reports that one of the two presented talkers was more intelligible, we found a reduced pupil size, increased parietal alpha power, and better performance when people listened to the more intelligible talker. Conclusions: We show that the modulation of sustained listening effort (e.g., by hearing aid noise reduction) as indicated by pupil size and parietal alpha power can be studied under more ecologically valid conditions. Mainly concluded from pupil size, we demonstrate that hearing aid noise reduction lowers sustained listening effort. Our study approximates to real-world listening scenarios and evaluates the benefit of the signal processing as can be found in a modern hearing aid.

Checked 2026-11-19 · 1 reference not checked yet

Overview

CoChat Summary

TL;DR

In 22 hearing-impaired participants listening to 33-second continuous news clips in multi-talker babble, hearing aid noise reduction reduced pupil size—a marker of sustained listening effort—especially at the lower +3 dB SNR, while SNR alone had no significant effect. Parietal alpha power showed a similar but non-significant pattern and was uncorrelated with pupil size trial-to-trial.

Key findings

  • Noise reduction significantly reduced pupil size (β = -0.046, SE = 0.008, t1172 = -5.66, p = 0.018*10^-6), but did not significantly affect parietal alpha power (β = 5.85, SE = 3.92, t1507 = 1.4, p = 0.136).
  • SNR had no significant effect on pupil size (β = -0.013, SE = 0.008, t1172 = -1.6, p = 0.107) or parietal alpha power (β = 5.9, SE = 3.91, t1507 = 1.53, p = 0.127); a significant SNR × noise reduction interaction on pupil size (β = 0.038, SE = 0.0164, t1172 = 2.31, p = 0.021) suggested noise reduction decreased pupil size more at +3 dB than +8 dB.
  • Talker 2 (the more intelligible talker) versus talker 1 produced reduced pupil size (β = -0.037, SE = 0.008, p = 0.0056*10^-3) and increased parietal alpha power (β = 9.2, SE = 3.90, t1507 = 2.35, p = 0.019); behavioral performance was also higher for talker 2 (β = 0.79 ≈ 9%, SE = 0.15, t1671 = 29.5, p = 0.014*10^-5).
  • Behavioral performance was well above chance (intercept β = 1.9 ≈ 87%, SE = 0.11, t1671 = 17.43, p = 0.001*10^-62), with no significant noise reduction effect (β = 0.22 ≈ 2%, p = 0.14) or SNR effect (β = 0.27 ≈ 3.1%, p = 0.067); pupil size and parietal alpha power showed no trial-to-trial relationship (p = 0.22 and p = 0.25).

Methods

  • Twenty-two hearing-impaired participants (age 40–80, mean = 67, SD = 11.2) with mild-to-moderate sensorineural hearing loss were recruited; pupil analysis included N = 16, EEG analysis N = 20, and both measures N = 15.
  • Participants listened to 33-second continuous news clips from two frontal talkers at ±22° with 16-talker babble from four rear loudspeakers; SNRs were +3 dB and +8 dB, and hearing aid noise reduction was blocked on/off. After each trial they answered a true/false content question (chance level 50%).
  • Pupil size and 64-channel EEG were recorded; parietal alpha power (8–13 Hz) was extracted from selected parietal channels. Linear/generalized linear mixed-effects models tested fixed effects of noise reduction, SNR, and talker with a random intercept per participant.

Limitations

  • Stated: non-individualized closed tips were used for signal control, whereas clinical fitting for mild-to-moderate loss with intact low-frequency hearing would often use open domes, potentially reducing the noise reduction effect; noise reduction was quantified once on a dummy head rather than in situ per patient.
  • Stated: no subjective ratings of listening effort or preference were collected; the cause of the talker difference cannot be inferred (e.g., energetic masking, semantic complexity, speech rate); the direction of alpha power modulation remains controversial; the blocked design introduced predictability and baseline pupil differences.
  • Evident from the text: final samples were reduced to 16 for pupil and 20 for EEG (15 with both), limiting power; the SNR manipulation produced no significant effect, alpha findings were non-significant, and pupil and alpha were uncorrelated, suggesting they may index different aspects of sustained listening effort.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1097/aud.0000000000001050

Cites

73 of 74 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 1 Not valid · 33 Not checked · 73 Own results and interpretations

48 more claims

Create a free account to see all 107 claims and to verify the 45 references still open.

See all claims — free account
  • It may state two separate claims as one. 22
  • Probably not a substantial claim. 42
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

4 of 4

Citations

Cites

Show all 73 references

Research works printed but not linked: 1

  1. Hagerman, 2004, A method to measure the effect of noise reduction algorithms using simultaneous speech and noise., Acta Acust united with Acust, 90, 356

Cited by

See all 80

Metadata

Authors
Fiedler, L., Seifi Ala, T., Graversen, C., Alickovic, E., Lunner, T., & Wendt, D.
Affiliations
  • Oticon (Denmark) (DK)
  • Eriksholm Research Centre, Oticon A/S, Snekkersten, Denmark
  • Linköping University (SE)
Corresponding author
Fiedler, Lorenz
Venue
Ear & Hearing
Published
2021-05-04
Volume
42
Issue
6
Pages
1590-1601
ISSN
  • 0196-0202 (ISSN-L)
  • 1538-4667
OpenAlex
W3157062869
Cited by
80
References
73
Citations by year
2026: 16 · 2025: 18 · 2024: 18 · 2023: 14 · 2022: 13 · 2021: 1
FWCI
9.39
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Ear and Hearing (publishedVersion)
  • PubMed (publishedVersion)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion, other-oa)
  • DiVA (Digitala Vetenskapliga Arkivet) (submittedVersion, other-oa)
Funders
European Commission
Topics
  • Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
  • Physical Sciences › Computer Science › Signal Processing › Speech and Audio Processing
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
Keywords
pupillometry, signal-to-noise ratio, multi-talker babble, hearing loss
MeSH terms
Listening Effort, Electroencephalography, Hearing Aids, Humans, Speech Intelligibility, Speech Perception, Hearing Loss

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hearing Aid Noise Reduction Lowers the Sustained Listening Effort During Continuous Speech in Noise—A Combined Pupillometry and EEG Study. https://app.cochat.ai/papers/10.1097/aud.0000000000001050
The paper
Fiedler, L., Seifi Ala, T., Graversen, C., Alickovic, E., Lunner, T., & Wendt, D. (2021). Hearing Aid Noise Reduction Lowers the Sustained Listening Effort During Continuous Speech in Noise—A Combined Pupillometry and EEG Study. Ear & Hearing. https://doi.org/10.1097/aud.0000000000001050

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.