Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults
Abstract
OBJECTIVE: To evaluate the quality of insertion of the Nucleus Contour and the newly developed Contour Advance electrode in adult cochlear implant recipients and to compare results of speech performance tests with regard to electrode position. DESIGN: A total of 43 adult patients with a history of progressive hearing loss having received a Nucleus cochlear implant, 21 of which had received a Contour electrode and 22 a Contour Advance electrode, were evaluated by rotational tomography after surgery. Electrode position was determined to be in scala tympani, scala vestibuli, or with a dislocation from one scala to the other. Speech test results were collected for Freiburg numbers, Freiburg monosyllables, and Oldenburg sentence tests 1 yr after surgery. RESULTS: The Contour array presented with a high rate of scala vestibuli insertions and a high rate of dislocations from scala tympani to scala vestibuli, whereas the Contour Advance array showed a high rate of scala tympani insertions with very few dislocations and few scala vestibuli insertions. Speech tests results varied with respect to the location of the intracochlear electrode position, with insertions into the scala tympani being significantly superior to the scala vestibuli. CONCLUSIONS: Results of studying the Contour array influenced the surgical procedure that improved surgical ability to perform insertions into the scala tympani by using the Contour Advance array. In addition, a comparison between Contour and Contour Advance electrode demonstrated an improved mechanical behavior of the Contour Advance electrode with a decrease of dislocation rate. The use of the Contour Advance electrode allows a more atraumatic electrode insertion, which is of interest with extending indications and the use of further advanced coding strategies. The intracochlear electrode position with regard to speech performance results demonstrated advantages of scala tympani insertions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 508
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
Skinner, M. W., Ketten, D. R., Holden, L. K., Harding, G. W., Smith, P. G., Gates, G. A., Neely, J. G., Kletzker, G. R., Brunsden, B., & Blocker, B. (2002) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620020013 · Cited by 223
Ketten, D. R., Skinner, M. W., Wang, G., Vannier, M. W., Gates, G. A., & Neely, J. G. (1998) · PubMed · Cited by 222
Quality Control after Cochlear Implant Surgery by Means of Rotational Tomography
Aschendorff, A., Kubalek, R., Turowski, B., Zanella, F. E., Hochmuth, A., Schumacher, M. C., Klenzner, T., & Laszig, R. (2005) · Otology & Neurotology · doi:10.1097/00129492-200501000-00007 · Cited by 155
Self-citationFraysse, B., Dillier, N., Klenzner, T., Laszig, R., Manrique, M. J., Pérez, C. M., Morgon, A., Müller-Deile, J., & Macías, Á. R. (1998) · PubMed · doi:10.5167/uzh-8346 · Cited by 58
Self-citationBacciu, S., Bacciu, A., Pasanisi, E., et al. (2002) · Otology & Neurotology · doi:10.1097/00129492-200205000-00019 · Cited by 33
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes
Wanna, G. B., Noble, J. H., Carlson, M. L., Gifford, R. H., Dietrich, M. S., Haynes, D. S., Dawant, B. M., & Labadie, R. F. (2014) · The Laryngoscope · doi:10.1002/lary.24728 · Cited by 321
Metadata
- Authors
- Aschendorff, A., Kromeier, J., Klenzner, T., & Laszig, R.
- Venue
- Ear & Hearing
- Published
- 2007-04
- Volume
- 28
- Issue
- 2
- Pages
- 75S-79S
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2091550421
- Cited by
- 310
- References
- 8
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.