Information From the Voice Fundamental Frequency (F0) Region Accounts for the Majority of the Benefit When Acoustic Stimulation Is Added to Electric Stimulation
Open accessThe DOI matches its Crossref record.
Abstract
In Brief Objectives: The aim of this study was to determine the minimum amount of low-frequency acoustic information that is required to achieve speech perception benefit in listeners with a cochlear implant in one ear and low-frequency hearing in the other ear. Design: The recognition of monosyllabic words in quiet and sentences in noise was evaluated in three listening conditions: electric stimulation alone, acoustic stimulation alone, and combined electric and acoustic stimulation. The acoustic stimuli presented to the nonimplanted ear were either low-pass-filtered at 125, 250, 500, or 750 Hz, or unfiltered (wideband). Results: Adding low-frequency acoustic information to electrically stimulated information led to a significant improvement in word recognition in quiet and sentence recognition in noise. Improvement was observed in the electric and acoustic stimulation condition even when the acoustic information was limited to the 125-Hz-low-passed signal. Further improvement for the sentences in noise was observed when the acoustic signal was increased to wideband. Conclusions: Information from the voice fundamental frequency (F0) region accounts for the majority of the speech perception benefit when acoustic stimulation is added to electric stimulation. We propose that, in quiet, low-frequency acoustic information leads to an improved representation of voicing, which in turn leads to a reduction in word candidates in the lexicon. In noise, the robust representation of voicing allows access to low-frequency acoustic landmarks that mark syllable structure and word boundaries. These landmarks can bootstrap word and sentence recognition. Information from F0 and the associated amplitude envelope accounts for the majority of the speech-perception benefit when acoustic stimulation is added to electric stimulation. We propose that, in quiet, low-frequency acoustic information leads to improved representation of voicing and manner, which in turn, leads to a reduction in word candidates in the lexicon. In noise, the robust representation of voicing allows access to low-frequency acoustic landmarks that mark syllable structure and word boundaries. These landmarks can bootstrap word and sentence recognition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Celepli, S., Bigat, I., Karakas, B., Tezcan, H. M., Yar, M. D., Celepli, P., Aksahin, M. F., Hancerliogullari, O., Yilmaz, Y. F., & Erogul, O. (2025) · Diagnostics · doi:10.3390/diagnostics15162065 · Cited by 6
Metadata
- Authors
- Zhang, T., Dorman, M. F., & Spahr, A. J.
- Venue
- Ear & Hearing
- Published
- 2010-02
- Volume
- 31
- Issue
- 1
- Pages
- 63-69
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W1987289325
- Cited by
- 177
- References
- 0
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Information From the Voice Fundamental Frequency (F0) Region Accounts for the Majority of the Benefit When Acoustic Stimulation Is Added to Electric Stimulation. https://app.cochat.ai/papers/10.1097/aud.0b013e3181b7190c
- The paper
- Zhang, T., Dorman, M. F., & Spahr, A. J. (2010). Information From the Voice Fundamental Frequency (F0) Region Accounts for the Majority of the Benefit When Acoustic Stimulation Is Added to Electric Stimulation. Ear & Hearing. https://doi.org/10.1097/aud.0b013e3181b7190c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.