CoChat

Cochlear Implantation in Children with Auditory Neuropathy Spectrum Disorder

Teagle, Holly F.B., Roush, Patricia A., Woodard, Jennifer S., Hatch, Debora R., Zdanski, Carlton J., Buss, Emily, Buchman, Craig A. · 2010 · Ear & Hearing
Cited by 227

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

In Brief Objective: To report the patient's characteristics, preoperative audiological profiles, surgical outcomes, and postoperative performance for children with auditory neuropathy spectrum disorder (ANSD) who ultimately received cochlear implants (CIs). Design: Prospective, longitudinal study of children with ANSD who received CIs after a stepwise management protocol that included electrophysiologic and medical assessment, documentation of behavioral audiometric thresholds and subsequent fitting of amplification according to Desired Sensation Level targets, auditory-based intervention with careful monitoring of skills development and communication milestones, and finally implantation when progress with the use of acoustic amplification was insufficient. Results: Of 140 children with ANSD, 52 (37%) received CIs in their affected ears (mean duration of use of 41 mos). Many of these children were born prematurely (42%) and impacted by a variety of medical comorbidities. More than one third (38%) had abnormal findings on preoperative magnetic resonance imaging of the brain and inner ear, and 81% had a greater than severe (>70 dB HL) degree of hearing loss before implantation. Although 50% of the implanted children with ANSD demonstrated open-set speech perception abilities after implantation, nearly 30% of them with >6 months of implant experience were unable to participate in this type of testing because of their young age or developmental delays. No child with cochlear nerve deficiency (CND) in their implanted ear achieved open-set speech perception abilities. In a subgroup of children, good open-set speech perception skills were associated with robust responses elicited on electrical-evoked intracochlear compound action potential testing when this assessment was possible. Conclusions: This report shows that children with ANSD who receive CIs are a heterogeneous group with a wide variety of impairments. Although many of these children may ultimately benefit from implantation, some will not, presumably because of a lack of electrical-induced neural synchronization, the detrimental effects of their other associated conditions, or a combination of factors. When preoperative magnetic resonance imaging reveals central nervous system pathology, this portends a poor prognosis for the development of open-set speech perception, particularly when CND is evident. These results also show that electrical-evoked intracochlear compound action potential testing may help identify those children who will develop good open-set speech perception. Instead of recommending CI for all children with electrophysiologic evidence of ANSD, the stepwise management procedure described herein allows for the identification of children who may benefit from amplification, those who are appropriate candidates for cochlear implantation, and those who, because of bilateral CND, may not be appropriate candidates for either intervention. The management of auditory neuropathy spectrum disorder (ANSD) in children remains challenging. Rather than categorically recommending cochlear implants for all children with the disorder, the present study used a stepwise management paradigm that includes medical assessment, documentation of behavioral audiometric thresholds, fitting of amplification, and finally implantation when progress in the use of acoustic amplification is insufficient. Results demonstrate the heterogeneous nature of the disorder and the variability in auditory perceptual skills using cochlear implants. Poor performance was associated with findings on preoperative magnetic resonance imaging and intracochlear compound action potential testing responses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aud.0b013e3181ce693b

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 227

Metadata

Authors
Teagle, H. F. B., Roush, P. A., Woodard, J. S., Hatch, D. R., Zdanski, C. J., Buss, E., & Buchman, C. A.
Venue
Ear & Hearing
Published
2010-06
Volume
31
Issue
3
Pages
325-335
ISSN
0196-0202 (ISSN-L)
OpenAlex
W2049699174
Cited by
227
References
16
FWCI
11.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cochlear Implantation in Children with Auditory Neuropathy Spectrum Disorder. https://app.cochat.ai/papers/10.1097/aud.0b013e3181ce693b
The paper
Teagle, H. F. B., Roush, P. A., Woodard, J. S., Hatch, D. R., Zdanski, C. J., Buss, E., & Buchman, C. A. (2010). Cochlear Implantation in Children with Auditory Neuropathy Spectrum Disorder. Ear & Hearing. https://doi.org/10.1097/aud.0b013e3181ce693b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.