The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions: A Randomized Controlled Trial
Abstract
STUDY DESIGN: A prospective randomized clinical trial. OBJECTIVE: To compare the impact of robotic guidance in a minimally invasive spine surgery (MIS) to a fluoroscopy-guided open approach in lumbar fusions. SUMMARY OF BACKGROUND DATA: MIS requires a protracted learning curve and excessively exposes the patient and surgical team to harmful radiation. Robotic-guidance has been shown to improve accuracy and radiation in most studies, but there is conflicting prospective data. METHODS: Patients indicated to undergo a 1 or 2 level spinal fusion were randomized between robotic-guided MIS (RO) and fluoroscopic-guided open surgery (FA). Patient demographics and outcomes were recorded. RESULTS: Thirty patients were recruited to each arm. Average age was 66.7 years, 71.5% were females, and average body mass index was 25.2. Thirty-five levels were instrumented with 130 pedicle screws in RO versus 40 levels with 140 screws in FA, or 4.3 and 4.7 screws per surgery, respectively. Use of fluoroscopy was 3.5 versus 13.3 seconds in the RO and FA respectively (P < 0.001). C-arm output in mSv was 0.13 versus 0.27 in the RO and FA respectively (P = 0.015). By thermoluminescent dosimeters, the average per-screw radiation in the RO arm was 37.5% of that in the FA arm, demonstrating a mean reduction of 62.5% in use of radiation. There was no difference in the improvement in Visual Analog Scale scores for back and leg or the Oswestry Disability Index. All screws were accurate in RO whereas two screws breached (>2 mm and >4 mm) in FA (P = 0.500). One proximal facet violation occurred in the study, it was in FA (P = 1.000). The average distance from the proximal facets was 5.8 versus 4.6 mm in the RO and FA respectively (P < 0.001). The average length of stay was 6.8 versus 9.4 days in RO compared with FA (P = 0.020). CONCLUSION: MIS using robotic-guidance significantly reduced radiation exposure and length of stay. Patient outcomes were not affected by the surgical technique. LEVEL OF EVIDENCE: 1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fairbank, J. C. T., & Pynsent, P. B. (2000) · Spine · doi:10.1097/00007632-200011150-00017 · Cited by 5,851
Accuracy of Pedicular Screw Placement In Vivo
GERTZBEIN, S. D., & ROBBINS, S. E. (1990) · Spine · doi:10.1097/00007632-199001000-00004 · Cited by 1,381
Streptomycin Treatment of Pulmonary Tuberculosis: A Medical Research Council Investigation
(1948) · BMJ · doi:10.1136/bmj.2.4582.769 · Cited by 986
Devito, D. P., Kaplan, L., Dietl, R., Pfeiffer, M., Horne, D., Silberstein, B., Hardenbrook, M., Kiriyanthan, G., Barzilay, Y., Bruskin, A., et al. (2010) · Spine · doi:10.1097/brs.0b013e3181d323ab · Cited by 407
The challenges faced in the design, conduct and analysis of surgical randomised controlled trials
Cook, J. A. (2009) · Trials · doi:10.1186/1745-6215-10-9 · Cited by 351
What is Efficient Vaccination?
Woods, H. (1891) · BMJ · doi:10.1136/bmj.2.1605.769 · Cited by 348
Tian, N.-F., Huang, Q.-S., Zhou, P., Zhou, Y., Wu, R.-K., Lou, Y., & Xu, H.-Z. (2011) · European Spine Journal · doi:10.1007/s00586-010-1577-5 · Cited by 345
Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review
Aoude, A. A., Fortin, M., Figueiredo, R., Jarzem, P., Ouellet, J., & Weber, M. H. (2015) · European Spine Journal · doi:10.1007/s00586-015-3853-x · Cited by 223
Minimally invasive versus open transforaminal lumbar interbody fusion
Burneikiene, S., Roeca, C., Nelson, L., Mason, A., & Villavicencio, A. (2010) · Surgical Neurology International · doi:10.4103/2152-7806.63905 · Cited by 175
Tian, N., Wu, Y., Zhang, X., Xu, H., Chi, Y.-L., & Mao, F.-M. (2013) · European Spine Journal · doi:10.1007/s00586-013-2747-z · Cited by 165
Metadata
- Authors
- Hyun, S.-J., Kim, K.-J., Jahng, T.-A., & Kim, H.-J.
- Venue
- Spine
- Published
- 2017-03-15
- Volume
- 42
- Issue
- 6
- Pages
- 353-358
- ISSN
- 0362-2436 (ISSN-L)
- 1528-1159
- OpenAlex
- W2463069568
- Cited by
- 305
- References
- 11
- FWCI
- 15.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.1097/brs.0000000000001778
- The paper
- Hyun, S.-J., Kim, K.-J., Jahng, T.-A., & Kim, H.-J. (2017). Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions: A Randomized Controlled Trial. Spine. https://doi.org/10.1097/brs.0000000000001778
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.