CoChat

PROMIS PF CAT Outperforms the ODI and SF-36 Physical Function Domain in Spine Patients

Open access
Brodke, Darrel S., Goz, Vadim, Voss, Maren W., Lawrence, Brandon D., Spiker, William Ryan, Hung, Man · 2017 · Spine
Cited by 167

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

STUDY DESIGN: The Oswestry Disability Index v2.0 (ODI), SF36 Physical Function Domain (SF-36 PFD), and PROMIS Physical Function CAT v1.2 (PF CAT) questionnaires were prospectively collected from 1607 patients complaining of back or leg pain, visiting a university-based spine clinic. All questionnaires were collected electronically, using a tablet computer. OBJECTIVE: The aim of this study was to compare the psychometric properties of the PROMIS PF CAT with the ODI and SF36 Physical Function Domain in the same patient population. SUMMARY OF BACKGROUND DATA: Evidence-based decision-making is improved by using high-quality patient-reported outcomes measures. Prior studies have revealed the shortcomings of the ODI and SF36, commonly used in spine patients. The PROMIS Network has developed measures with excellent psychometric properties. The Physical Function domain, delivered by Computerized Adaptive Testing (PF CAT), performs well in the spine patient population, though to-date direct comparisons with common measures have not been performed. METHODS: Standard Rasch analysis was performed to directly compare the psychometrics of the PF CAT, ODI, and SF36 PFD. Spearman correlations were computed to examine the correlations of the three instruments. Time required for administration was also recorded. RESULTS: One thousand six hundred seven patients were administered all assessments. The time required to answer all items in the PF CAT, ODI, and SF-36 PFD was 44, 169, and 99 seconds. The ceiling and floor effects were excellent for the PF CAT (0.81%, 3.86%), while the ceiling effects were marginal and floor effects quite poor for the ODI (6.91% and 44.24%) and SF-36 PFD (5.97% and 23.65%). All instruments significantly correlated with each other. CONCLUSION: The PROMIS PF CAT outperforms the ODI and SF-36 PFD in the spine patient population and is highly correlated. It has better coverage, while taking less time to administer with fewer questions to answer. LEVEL OF EVIDENCE: 2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0000000000001965

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 167

Metadata

Authors
Brodke, D. S., Goz, V., Voss, M. W., Lawrence, B. D., Spiker, W. R., & Hung, M.
Venue
Spine
Published
2017-06-15
Volume
42
Issue
12
Pages
921-929
ISSN
  • 0362-2436 (ISSN-L)
  • 1528-1159
OpenAlex
W2541152911
Cited by
167
References
8
FWCI
13.16
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PROMIS PF CAT Outperforms the ODI and SF-36 Physical Function Domain in Spine Patients. https://app.cochat.ai/papers/10.1097/brs.0000000000001965
The paper
Brodke, D. S., Goz, V., Voss, M. W., Lawrence, B. D., Spiker, W. R., & Hung, M. (2017). PROMIS PF CAT Outperforms the ODI and SF-36 Physical Function Domain in Spine Patients. Spine. https://doi.org/10.1097/brs.0000000000001965

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.