Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 359

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Diagnostic Imaging of Spinal Deformities: Reducing Patients Radiation Dose With a New Slot-Scanning X-ray Imager

Deschênes, Sylvain, Charron, Guy, Beaudoin, Gilles, Labelle, Hubert, Dubois, Josée, Miron, Marie-Claude, Parent, Stefan · 2010 · Spine

Abstract

STUDY DESIGN: Clinical trial comparing image quality and entrance dose between Biospace EOS system, a new slot-scanning radiographic device, and a Fuji FCR 7501S computed radiography (CR) system for 50 patients followed for spinal deformities. OBJECTIVE: Based on their physical properties, slot-scanners show the potential to produce image quality comparable to CR systems using less radiation. This article validates this assertion by comparing a new slot-scanner to a CR system through a wide-ranging evaluation of dose and image quality for scoliosis examinations. SUMMARY OF BACKGROUND DATA: For each patient included in this study, lateral and posteroanterior images were acquired with both systems. For each system, entrance dose was measured for different anatomic locations. METHODS: Dose and image quality being directly related, comparable images were obtained using the same radiograph tube voltage on both systems while tube currents were selected to match signal-to-noise ratios on a phantom. Different techniques were defined with respect to patient's thickness about the iliac crests. Given dose amplitudes expected for scoliosis examinations, optically stimulated luminescence dosimeters were chosen as optimal sensors. Two radiologists and 2 orthopedists evaluated the images in a randomized order using a questionnaire targeting anatomic landmarks. Visibility of the structures was rated on a 4 level scale. Image quality assessment was analyzed using a Wilcoxon signed-rank tests. RESULTS: Average skin dose was reduced from 6 to 9 times in the thoracoabdominal region when using the slot-scanner instead of CR. Moreover, image quality was significantly better with EOS for all structures in the frontal view (P < 0.006) and lateral view (P < 0.04), except for lumbar spinous processes, better seen on the CR (P < 0.003). CONCLUSION: We established that the EOS system offers overall enhanced image quality while reducing drastically the entrance dose for the patient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0b013e3181bdcaa4

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Deschênes, S., Charron, G., Beaudoin, G., Labelle, H., Dubois, J., Miron, M.-C., & Parent, S.
Venue
Spine
Published
2010-04
Volume
35
Issue
9
Pages
989-994
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2045607856
Cited by
359
References
4
FWCI
13.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.