Assessment of Cervical Spondylotic Myelopathy Using Diffusion Tensor Magnetic Resonance Imaging Parameter at 3.0 Tesla

Uda, Takehiro, Takami, Toshihiro, Tsuyuguchi, Naohiro, Sakamoto, Shinichi, Yamagata, Toru, Ikeda, Hidetoshi, Nagata, Takashi, Ohata, Kenji · 2013 · Spine
Cited by 63

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In Brief Study Design. Cross-sectional study. Objective. To assess spinal cord condition in patients with cervical spondylosis (CS), using diffusion tensor imaging parameter. Summary of Background Data. Although myelopathy is a common symptom after CS, clinically objective assessment for determination of surgical intervention is not straightforward. Methods. Twenty-six patients with CS and 30 normal control subjects were enrolled. Diffusion tensor imaging was obtained using a single-shot fast spin-echo–based sequence at 3.0 T. Mean diffusivity (MD) and fractional anisotropy (FA) were measured in the axial plane at 6 spinal levels. To evaluate MD and FA in patients with CS considering the normal variation at each spinal level and between spinal levels, MD and FA at the most compressed spinal level were transformed to normalized values with a z score. Presence of myelopathy was predicted with the MD and FA z scores. Diagnostic validity of MD and FA was compared with receiver operating characteristic analysis. More effective parameter and the optimal cutoff value for prediction were determined. Results. In normal subjects, MD and FA were significantly different between spinal levels. In patients with myelopathy, an MD increase or an FA decrease was demonstrated in most cases. Although both an MD increase and an FA decrease had diagnostic validity for myelopathy, receiver operating characteristic analysis demonstrated a higher sensitivity and specificity for prediction of an MD increase than an FA decrease (areas under the curve for MD and FA were 0.903 and 0.760, respectively). An MD z score of 1.40 was considered to be the best diagnostic cutoff value with 100% sensitivity and 75% specificity. Conclusion. Myelopathy can be predicted with high accuracy with diffusion tensor imaging parameter, with the MD z score at the most compressed spinal level. Level of Evidence: 3 Functional disturbance due to cervical spondylosis was assessed using diffusion tensor imaging parameters (mean diffusivity and fractional anisotropy). More effective parameter and the optimal cutoff value for prediction of myelopathy were determined. Myelopathy was predicted with high accuracy, with the z score of mean diffusivity at the most compressed spinal level.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0b013e31826f25a3

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 63

Metadata

Authors
Uda, T., Takami, T., Tsuyuguchi, N., Sakamoto, S., Yamagata, T., Ikeda, H., Nagata, T., & Ohata, K.
Venue
Spine
Published
2013-03
Volume
38
Issue
5
Pages
407-414
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2057648503
Cited by
63
References
3
FWCI
6.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.