The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Lung-Protective Ventilation With Low Tidal Volumes and the Occurrence of Pulmonary Complications in Patients Without Acute Respiratory Distress Syndrome: A Systematic Review and Individual Patient Data Analysis*
Open accessAbstract
OBJECTIVE: Protective mechanical ventilation with low tidal volumes is standard of care for patients with acute respiratory distress syndrome. The aim of this individual patient data analysis was to determine the association between tidal volume and the occurrence of pulmonary complications in ICU patients without acute respiratory distress syndrome and the association between occurrence of pulmonary complications and outcome in these patients. DESIGN: Individual patient data analysis. PATIENTS: ICU patients not fulfilling the consensus criteria for acute respiratory distress syndrome at the onset of ventilation. INTERVENTIONS: Mechanical ventilation with low tidal volume. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was development of a composite of acute respiratory distress syndrome and pneumonia during hospital stay. Based on the tertiles of tidal volume size in the first 2 days of ventilation, patients were assigned to a "low tidal volume group" (tidal volumes ≤ 7 mL/kg predicted body weight), an "intermediate tidal volume group" (> 7 and < 10 mL/kg predicted body weight), and a "high tidal volume group" (≥ 10 mL/kg predicted body weight). Seven investigations (2,184 patients) were included. Acute respiratory distress syndrome or pneumonia occurred in 23% of patients in the low tidal volume group, in 28% of patients in the intermediate tidal volume group, and in 31% of the patients in the high tidal volume group (adjusted odds ratio [low vs high tidal volume group], 0.72; 95% CI, 0.52-0.98; p = 0.042). Occurrence of pulmonary complications was associated with a lower number of ICU-free and hospital-free days and alive at day 28 (10.0 ± 10.9 vs 13.8 ± 11.6 d; p < 0.01 and 6.1 ± 8.1 vs 8.9 ± 9.4 d; p < 0.01) and an increased hospital mortality (49.5% vs 35.6%; p < 0.01). CONCLUSIONS: Ventilation with low tidal volumes is associated with a lower risk of development of pulmonary complications in patients without acute respiratory distress syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
A trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843 · cited 3×
“Consequently, ICU clinicians remain uncertain on whether low tidal volumes should be used in all ICU patients, that is, irrespective of the presence of ARDS (5, 6).”
Self-citation
Cited by
on behalf of the section Respiratory Failure of the European Society for Paediatric and Neonatal Intensive Care, Kneyber, M. C. J., de Luca, D., Calderini, E., Jarreau, P.-H., Javouhey, E., Lopez-Herce, J., Hammer, J., Macrae, D., Markhorst, D. G., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4920-z · Cited by 351
Writing Group for the PReVENT Investigators, Simonis, F. D., Serpa Neto, A., Binnekade, J. M., Braber, A., Bruin, K. C. M., Determann, R. M., Goekoop, G.-J., Heidt, J., Horn, J., et al. (2018) · JAMA · doi:10.1001/jama.2018.14280 · Cited by 279
Self-citationPositive pressure ventilation in the cardiac intensive care unit
Alviar, C. L., Miller, P. E., McAreavey, D., Katz, J. N., Lee, B., Moriyama, B., Soble, J., van Diepen, S., Solomon, M. A., & Morrow, D. A. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.074 · Cited by 271
Nieman, G. F., Satalin, J., Andrews, P., Aiash, H., Habashi, N. M., & Gatto, L. A. (2017) · Intensive Care Medicine Experimental · doi:10.1186/s40635-017-0121-x · Cited by 143
Metadata
- Authors
- Neto, A. S., Simonis, F. D., Barbas, C. S. V., Biehl, M., Determann, R. M., Elmer, J., Friedman, G., Gajic, O., Goldstein, J. N., Linko, R., Pinheiro de Oliveira, R., Sundar, S., Talmor, D., Wolthuis, E. K., Gama de Abreu, M., Pelosi, P., & Schultz, M. J.
- Venue
- Critical Care Medicine
- Published
- 2015-10
- Volume
- 43
- Issue
- 10
- Pages
- 2155-2163
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1476289819
- Cited by
- 246
- References
- 4
- FWCI
- 26.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lung-Protective Ventilation With Low Tidal Volumes and the Occurrence of Pulmonary Complications in Patients Without Acute Respiratory Distress Syndrome: A Systematic Review and Individual Patient Data Analysis*. https://app.cochat.ai/papers/10.1097/ccm.0000000000001189
- The paper
- Neto, A. S., Simonis, F. D., Barbas, C. S. V., Biehl, M., Determann, R. M., Elmer, J., Friedman, G., Gajic, O., Goldstein, J. N., Linko, R., Pinheiro de Oliveira, R., Sundar, S., Talmor, D., Wolthuis, E. K., Gama de Abreu, M., Pelosi, P., & Schultz, M. J. (2015). Lung-Protective Ventilation With Low Tidal Volumes and the Occurrence of Pulmonary Complications in Patients Without Acute Respiratory Distress Syndrome: A Systematic Review and Individual Patient Data Analysis*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000001189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.