Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multisignal Vital Sign Monitoring Data*
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objective: The use of machine-learning algorithms to classify alerts as real or artifacts in online noninvasive vital sign data streams to reduce alarm fatigue and missed true instability. Design: Observational cohort study. Setting: Twenty-four–bed trauma step-down unit. Patients: Two thousand one hundred fifty-three patients. Intervention: Noninvasive vital sign monitoring data (heart rate, respiratory rate, peripheral oximetry) recorded on all admissions at 1/20 Hz, and noninvasive blood pressure less frequently, and partitioned data into training/validation (294 admissions; 22,980 monitoring hours) and test sets (2,057 admissions; 156,177 monitoring hours). Alerts were vital sign deviations beyond stability thresholds. A four-member expert committee annotated a subset of alerts (576 in training/validation set, 397 in test set) as real or artifact selected by active learning, upon which we trained machine-learning algorithms. The best model was evaluated on test set alerts to enact online alert classification over time. Measurements and Main Results: The Random Forest model discriminated between real and artifact as the alerts evolved online in the test set with area under the curve performance of 0.79 (95% CI, 0.67–0.93) for peripheral oximetry at the instant the vital sign first crossed threshold and increased to 0.87 (95% CI, 0.71–0.95) at 3 minutes into the alerting period. Blood pressure area under the curve started at 0.77 (95% CI, 0.64–0.95) and increased to 0.87 (95% CI, 0.71–0.98), whereas respiratory rate area under the curve started at 0.85 (95% CI, 0.77–0.95) and increased to 0.97 (95% CI, 0.94–1.00). Heart rate alerts were too few for model development. Conclusions: Machine-learning models can discern clinically relevant peripheral oximetry, blood pressure, and respiratory rate alerts from artifacts in an online monitoring dataset (area under the curve > 0.87).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sendelbach, S., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.4037/nci.0b013e3182a903f9 · Cited by 497
Drew, B. J., Harris, P., Zègre-Hemsey, J. K., Mammone, T., Schindler, D., Salas-Boni, R., Bai, Y., Tinoco, A., Ding, Q., & Hu, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110274 · Cited by 438 · cited 1×
“Although “alarm hazards” remain at or near the top 10 technology safety concerns (36, 37), it is vital that mechanisms to improve monitoring safety are undertaken.”
BackgroundRayo, M. F., & Moffatt-Bruce, S. D. (2015) · BMJ Quality & Safety · doi:10.1136/bmjqs-2014-003373 · Cited by 115 · cited 1×
“Bedside instability recognition is impaired by the lack of discrimination between real alerts and artifact (34, 35).”
BackgroundKruppa, J., Liu, Y., Biau, G., Kohler, M., König, I. R., Malley, J. D., & Ziegler, A. (2014) · Biometrical Journal · doi:10.1002/bimj.201300068 · Cited by 97 · cited 1×
“Machine learning (ML) techniques learn models encapsulating differential patterns through training on a set of known data (17, 18), and the models then classify new, unseen examples (19).”
BackgroundCouceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33 · cited 1×
“This presents a significant problem in clinical care, as the majority of single VS threshold alerts are clinically irrelevant artifacts (10, 11).”
Background
Cited by
Hatib, F., Jian, Z., Buddi, S., Lee, C., Settels, J., Sibert, K., Rinehart, J., & Cannesson, M. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002300 · Cited by 614
Role of artificial intelligence in patient safety outcomes: systematic literature review
Choudhury, A., & Asan, O. (2020) · JMIR Medical Informatics · doi:10.2196/18599 · Cited by 440
Maassen, O., Fritsch, S., Palm, J., Deffge, S., Kunze, J., Marx, G., Riedel, M., Schuppert, A., & Bickenbach, J. (2021) · Journal of Medical Internet Research · doi:10.2196/26646 · Cited by 125
“2 Reduction of false alarms in intensive care medicine [58]”
Background
Metadata
- Authors
- Chen, L., Dubrawski, A., Wang, D., Fiterau, M., Guillame-Bert, M., Bose, E., Kaynar, A. M., Wallace, D. J., Guttendorf, J., Clermont, G., Pinsky, M. R., & Hravnak, M.
- Venue
- Critical Care Medicine
- Published
- 2016-07
- Volume
- 44
- Issue
- 7
- Pages
- e456-e463
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2324458257
- Cited by
- 75
- References
- 5
- FWCI
- 9.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multisignal Vital Sign Monitoring Data*. https://app.cochat.ai/papers/10.1097/ccm.0000000000001660
- The paper
- Chen, L., Dubrawski, A., Wang, D., Fiterau, M., Guillame-Bert, M., Bose, E., Kaynar, A. M., Wallace, D. J., Guttendorf, J., Clermont, G., Pinsky, M. R., & Hravnak, M. (2016). Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multisignal Vital Sign Monitoring Data*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000001660
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.