Measuring Patient Mobility in the ICU Using a Novel Noninvasive Sensor
Open accessThe DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Abstract
Objectives: To develop and validate a noninvasive mobility sensor to automatically and continuously detect and measure patient mobility in the ICU. Design: Prospective, observational study. Setting: Surgical ICU at an academic hospital. Patients: Three hundred sixty-two hours of sensor color and depth image data were recorded and curated into 109 segments, each containing 1,000 images, from eight patients. Interventions: None. Measurements and Main Results: Three Microsoft Kinect sensors (Microsoft, Beijing, China) were deployed in one ICU room to collect continuous patient mobility data. We developed software that automatically analyzes the sensor data to measure mobility and assign the highest level within a time period. To characterize the highest mobility level, a validated 11-point mobility scale was collapsed into four categories: nothing in bed, in-bed activity, out-of-bed activity, and walking. Of the 109 sensor segments, the noninvasive mobility sensor was developed using 26 of these from three ICU patients and validated on 83 remaining segments from five different patients. Three physicians annotated each segment for the highest mobility level. The weighted Kappa (κ) statistic for agreement between automated noninvasive mobility sensor output versus manual physician annotation was 0.86 (95% CI, 0.72–1.00). Disagreement primarily occurred in the “nothing in bed” versus “in-bed activity” categories because “the sensor assessed movement continuously,” which was significantly more sensitive to motion than physician annotations using a discrete manual scale. Conclusions: Noninvasive mobility sensor is a novel and feasible method for automating evaluation of ICU patient mobility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In hospitals, for example, early works have demonstrated CV-based ambient intelligence in intensive care units to monitor for safety-critical behaviors such as hand hygiene activity 32 and patient mobilization 8,129,130 .”
From Deep learning-enabled medical computer vision (2021) · cites this paper as [129]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Cortes, C., & Vapnik, V. (1995) · Machine-mediated learning · doi:10.1023/a:1022627411411 · Cited by 48,445
Caffe: Convolutional Architecture for Fast Feature Embedding
Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., & Darrell, T. (2014) · Proceedings of the 22nd ACM international conference on Multimedia · doi:10.1145/2647868.2654889 · Cited by 11,077
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736
Large-Scale Video Classification with Convolutional Neural Networks
Karpathy, A., Toderici, G., Shetty, S., Leung, T., Sukthankar, R., & Fei-Fei, L. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.223 · Cited by 6,354
Schweickert, W. D., Pohlman, M. C., Pohlman, A. S., Nigos, C., Pawlik, A. J., Esbrook, C. L., Spears, L., Miller, M., Franczyk, M., Deprizio, D., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60658-9 · Cited by 3,339
Learning Hierarchical Features for Scene Labeling
Farabet, C., Couprie, C., Najman, L., & LeCun, Y. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.231 · Cited by 2,620
Selecting and interpreting measures of thematic classification accuracy
Stehman, S. V. (1997) · Remote Sensing of Environment · doi:10.1016/s0034-4257(97)00083-7 · Cited by 1,729
Early intensive care unit mobility therapy in the treatment of acute respiratory failure*
Morris, P. E., Goad, A., Thompson, C., Taylor, K., Harry, B., Passmore, L., Ross, A., Anderson, L., Baker, S., Sanchez, M., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318180b90e · Cited by 1,349
MetaCost: a general method for making classifiers cost-sensitive
Domingos, P. (1999) · Proceedings of the fifth ACM SIGKDD international conference on Knowledge discovery and data mining · doi:10.1145/312129.312220 · Cited by 1,303
Cited by
Deep learning-enabled medical computer vision
Esteva, A., Chou, K., Yeung, S., Naik, N., Madani, A., Mottaghi, A., Liu, Y., Topol, E., Dean, J., & Socher, R. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00376-2 · Cited by 1,406
Illuminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274
“2b) and collected 362 h of data from eight patients 28 .”
BackgroundGraph Neural Networks in IoT: A Survey
Dong, G., Tang, M., Wang, Z., Gao, J., Guo, S., Cai, L., Gutierrez, R., Campbel, B., Barnes, L. E., & Boukhechba, M. (2023) · ACM Transactions on Sensor Networks · doi:10.1145/3565973 · Cited by 196
“For instance, camera and multiple sensors-based methods applied in intensive care units (ICU) help with continuously monitoring patients’ physiological indicators and activities, which relieves the burden of wearing complex medical sensors [180, 181].”
BackgroundIntelligent ICU for Autonomous Patient Monitoring Using Pervasive Sensing and Deep Learning
Davoudi, A., Malhotra, K. R., Shickel, B., Siegel, S., Williams, S., Ruppert, M., Bihorac, E., Ozrazgat-Baslanti, T., Tighe, P. J., Bihorac, A., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-44004-w · Cited by 158
Yeung, S., Rinaldo, F., Jopling, J., Liu, B., Mehra, R., Downing, N. L., Guo, M., Bianconi, G. M., Alahi, A., Lee, J., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0087-z · Cited by 125
CAI4CAI: The Rise of Contextual Artificial Intelligence in Computer Assisted Interventions
Vercauteren, T., Unberath, M., Padoy, N., & Navab, N. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2946993 · Cited by 125
“For the intensive care unit, [143], [144] present methods based on color or depth video data for the detection of patient mobilization activities.”
MethodActigraphy to Evaluate Sleep in the Intensive Care Unit. A Systematic Review
Schwab, K. E., Ronish, B., Needham, D. M., To, A. Q., Martin, J. L., & Kamdar, B. B. (2018) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201801-004oc · Cited by 120
Self-citationGonzález-Seguel, F., Corner, E. J., & Merino-Osorio, C. (2018) · Physical Therapy · doi:10.1093/ptj/pzy158 · Cited by 58
Privacy-Preserving Action Recognition for Smart Hospitals using Low-Resolution Depth ImagesPreprint
Chou, E., Tan, M., Zou, C., Guo, M., Haque, A., Milstein, A. S., & Fei-Fei, L. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1811.09950 · Cited by 66
“Vision-based activity monitoring has been deployed to track hand-hygiene compliance [10], perform activity logging in ICU facilities [18, 16], and detect anomalous behaviors like falls in senior home facilities [17], demonstrating the potential of such systems to reduce disease, decrease human…”
BackgroundPsychometric Properties of the Barthel Index Used at Intensive Care Unit Discharge
dos Reis, N. F., Figueiredo, F. C. X. S. D., Biscaro, R. R. M., Lunardelli, E. B., & Maurici, R. (2021) · American Journal of Critical Care · doi:10.4037/ajcc2022732 · Cited by 51
Human Pose Estimation on Privacy-Preserving Low-Resolution Depth Images
Srivastav, V., Gangi, A., & Padoy, N. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32254-0_65 · Cited by 61
Recent advances in the technology of anesthesia
Seger, C. D., & Cannesson, M. P. (2020) · F1000Research · doi:10.12688/f1000research.24059.1 · Cited by 51
Automatic Operating Room Surgical Activity Recognition for Robot-Assisted Surgery
Sharghi, A., Haugerud, H., Oh, D. S., & Mohareri, O. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59716-0_37 · Cited by 55
Digital Image Processing and IoT in Smart Health Care -A review
Kansal, I., Popli, R., Verma, J., Bhardwaj, V., & Bhardwaj, R. (2022) · International Conference on Emerging Smart Computing and Informatics (ESCI) · doi:10.1109/esci53509.2022.9758227 · Cited by 32
Outcomes prediction in longitudinal data: Study designs evaluation, use case in ICU acquired sepsis
Schvetz, M., Fuchs, L., Novack, V., & Moskovitch, R. (2021) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2021.103734 · Cited by 26
Puh, U., Hoehlein, B., & Deutsch, J. E. (2019) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2018.12.006 · Cited by 19
Fazio, S., Doroy, A. L., Marto, N. D., Taylor, S. L., Anderson, N., Young, H. M., & Adams, J. Y. (2020) · Critical Care Explorations · doi:10.1097/cce.0000000000000091 · Cited by 23
“Although our sample size and monitoring period were larger than similar sensor validation studies (12, 36, 38, 39, 41), 24 hours still provided a limited view of ICU mobility, especially as higher levels of mobility occur infrequently.”
BackgroundMethodResultAn Edge Computing and Ambient Data Capture System for Clinical and Home Environments
Suresha, P. B., Hegde, C., Jiang, Z., & Clifford, G. D. (2022) · Sensors · doi:10.3390/s22072511 · Cited by 16
“In clinical environments such as operating rooms (ORs) and intensive care units (ICUs), key events during patient monitoring include: (1) Patient movements while lying in bed and in mobility within the room [1,2]; (2) Bedside monitor alarm triggers and noise pollution [2–6]; (3) Presence, absence and movement of clini…”
BackgroundMethodRGB-D scene analysis in the NICU
Dosso, Y. S., Greenwood, K., Harrold, J., & Green, J. R. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104873 · Cited by 16
Smits, M., Nacar, M., Ludden, G., & van Goor, H. (2022) · Value in Health · doi:10.1016/j.jval.2021.11.1372 · Cited by 14
Multi-view Surgical Video Action Detection via Mixed Global View Attention
Schmidt, A., Sharghi, A., Haugerud, H., Oh, D. S., & Mohareri, O. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87202-1_60 · Cited by 19
Deep learning to quantify care manipulation activities in neonatal intensive care units
Majeedi, A., McAdams, R. M., Kaur, R., Gupta, S., Singh, H., & Li, Y. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01164-y · Cited by 12
“Video-based, automated monitoring of patient mobilization activities has been previously studied in adult ICUs 17,18 .”
Developing ICU Clinical Behavioral Atlas Using Ambient Intelligence and Computer Vision
Dai, W., Adeli, E., Luo, Z., Dash, D., Lakshmikanth, S. K., Durante, Z., Tang, P. C., Kaushal, A., Milstein, A. S., Fei-Fei, L., et al. (2025) · NEJM AI · doi:10.1056/aioa2400590 · Cited by 10
Rehabilitation and In-Hospital Mortality in COVID-19 Patients
Ambrose, A. F., Kurra, A., Tsirakidis, L., Hunt, K., Ayers, E. I., Gitkind, A. I., Yerra, S., Lo, Y., Ortiz, N., Jamal, F., et al. (2021) · The Journals of Gerontology Series A · doi:10.1093/gerona/glab321 · Cited by 12
“To minimize classification errors, the eight levels in the scale were collapsed into three categories as was done in previous studies (24, 25): A.”
MethodAmbient intelligence–based monitoring of staff and patient activity in the intensive care unit
Chan, P., Tay, A., Chen, D. C., Freitas, M. D., Millet, C., Nguyen-Duc, T., Duke, G. J., Lyall, J., Nguyen, J. T., McNeil, J. J., et al. (2022) · Australian Critical Care · doi:10.1016/j.aucc.2022.08.011 · Cited by 11
Potentials and Challenges of Pervasive Sensing in the Intensive Care Unit
Davoudi, A., Shickel, B., Tighe, P., Bihorac, A., & Rashidi, P. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.773387 · Cited by 5
“…potential applications of computer vision for fall detection (26, 27), sleep pose detection (28), agitation detection (29), physical activity monitoring ( 30, 31), head pose detection (22), physiological signal monitoring (32), and visitation detection (22, 33) in hospital settings ( Figure 1 ).”
BackgroundKhan, S. S., Mishra, P. K., Ye, B., Newman, K., Iaboni, A., & Mihailidis, A. (2023) · Canadian Conference on Computer and Robot Vision · doi:10.1109/crv60082.2023.00041 · Cited by 9
Subtypes of Delirium: A Step Toward Precision Medicine*
Stevens, R. D., & Zink, E. K. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003462 · Cited by 6
Mobilisation auf Intensivstationen: Intensivpflegezimmer und Medizintechnik können helfen
Grunow, J. J., Nydahl, P., & Schaller, S. J. (2022) · AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie · doi:10.1055/a-1324-0627 · Cited by 6
Garau, N., Fruet, D., Luchetti, A., Natale, F. G. B. D., & Conci, N. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.117172 · Cited by 6
Recent advances in research, training and teaching in anaesthesia and critical care
Hemantkumar, I., Sanwatsarkar, S., Babu, M. N., Kaur, S., Dogra, N., & Bajwa, S. S. (2023) · Indian Journal of Anaesthesia · doi:10.4103/ija.ija_1047_22 · Cited by 6
“patients’ mobility in the ICU and lower the burden of measurement and documentation on the caregiver.[29,30]”
Backgrounde-PEMICU: an e-Health Platform to Support Early Mobilisation in Intensive Care Units
Martínez-Ballesté, A., Sarroca, P. G., Mariné-Tena, A., Batista, E., & Solanas, A. (2019) · International Conference on Information, Intelligence, Systems & Applications (IISA) · doi:10.1109/iisa.2019.8900718 · Cited by 5
“Thus, we base our solution on mobile devices and low footprint motion sensors, which use in this area is still in its infancy [9], [10].”
BackgroundAutomated patient localization in challenging hospital environments
Jan, M. T., Garbin, C., Ruetschi, J., Marques, O., & Kalva, H. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-024-18118-x · Cited by 6
“More closely related to our work, [35–37] used object detection methods in applications to track patient mobility and activity.”
Rawat, N., Rao, V. N., Peven, M., Shrock, C. L., Reiter, A., Saria, S., & Ali, H. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003852 · Cited by 5
“We had previously collapsed the 11-point scale to a 4-point scale due to the unavailability of image data for several levels of the scale and our inability to capture walking outside of the room (4).”
BackgroundMethodSelf-citationFazio, S., Doroy, A. L., Anderson, N., Adams, J. Y., & Young, H. M. (2020) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2020.102949 · Cited by 7
Feng, R., Richter, F., Mari, E., Gleason, A., Le, C., Kellner, C. P., Shrivastava, R. K., Fields, M. C., Rapoport, B. I., Bederson, J. B., et al. (2026) · Neurosurgery · doi:10.1227/neu.0000000000003899 · Cited by 4
Remote Proactive Physiologic Monitoring in the ICU
Ramnath, V. R., & Malhotra, A. (2019) · Springer eBooks · doi:10.1007/978-3-030-11569-2_2 · Cited by 6
Payán-Salcedo, H. A., Aguilera, A., Batioja, M. F. S., & Diaz, L. M. C. (2025) · Indian Journal of Critical Care Medicine · doi:10.5005/jp-journals-10071-25070 · Cited by 3
“30–33 Other studies in our review, such as those by Reiter et al. 26 and Ma et al., 27 demonstrated that noninvasive mobility sensors accurately detected motor activity in patients admitted to the ICU, strongly agreeing with traditional assessment scales.”
Patient wearable technology in the ICU
Coffman, L. (2018) · Nursing Critical Care · doi:10.1097/01.ccn.0000534929.31666.37 · Cited by 4
Digital Transformation: The Smart ICU
Pérez-Fernández, J., Raimondi, N., & Cabezas, F. M. (2020) · Springer eBooks · doi:10.1007/978-3-030-33808-4_9 · Cited by 4
Methods for Routine Sleep Assessment and Monitoring
Pile, A. O., Feldman, E. B., Martin, J. L., & Kamdar, B. B. (2022) · Springer eBooks · doi:10.1007/978-3-031-06447-0_13 · Cited by 2
Güder, G., von Rein, E., Flohr, T., Weismann, D., Schmitt, D. R., Störk, S., Frantz, S., Kratzer, V., & Kendi, C. (2023) · Applied Sciences · doi:10.3390/app13169319 · Cited by 2
“tested a noninvasive mobility sensor using an RBG-D (red–blue–green–depth) camera in patients at the ICU [8,9].”
MethodA Lidar-based computer vision system for monitoring of patients in medical scenesPreprint
Wu, X., Zhang, H., Kong, C., Wang, Y., Ju, Y., & Zhao, C. (2023) · Research Square · doi:10.21203/rs.3.rs-2760999/v1 · Cited by 1
Viewpoint Invariant Convolutional Networks for Identifying Risky Hand Hygiene Scenarios
Guo, M., Haque, A., Yeung, S. Y., Jopling, J. K., Downing, N. L., Alahi, A., Campbell, B., Deru, K., Beninati, W., Milstein, A. S., et al. (2017) · Infoscience (Ecole Polytechnique Fédérale de Lausanne)
Could “Big Brother” Be Joining the Early Mobilization Team?*
Connolly, B. A. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003886
“Importantly for this, clinician and patient feedback from those participating in the NIMS evaluation did not suggest any concern with the presence and operation of the monitors (7).”
BackgroundMethodExercise interventions with critically ill patients in an Australian tertiary intensive care unit
Nickels, M. (2020) · Queensland University of Technology · doi:10.5204/thesis.eprints.206174
Posture Recognition in the Critical Care Settings using Wearable DevicesPreprint
Davoudi, A., Tighe, P. J., Bihorac, A., & Rashidi, P. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2110.02768
“Another promising approach for posture recognition is using computer vision, which has been researched in both non-hospital settings and hospital settings, including several studies in the ICU (1, 28-30).”
Artificial intelligence in precision medicine and liver disease monitoring
Su, T., & Kao, J. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99136-0.00016-7 · Cited by 1
ПОСЛЕДНИЕ ПРОРЫВЫ В ОБЛАСТИ ТЕХНОЛОГИИ АНЕСТЕЗИИ
Сексенбаев, С. Ж., & Бапанов, Б. А. (2023) · ICSP «NEW SCIENCE» eBooks · doi:10.46916/19092023-978-5-00215-082-3
Deshpande, A. H., Borkar, S. S., & Baheti, J. (2025) · Algorithms for intelligent systems · doi:10.1007/978-981-96-3648-8_3 · Cited by 1
Veerapaneni, R. K., & Delhibabu, R. (2026) · Frontiers in Blockchain · doi:10.3389/fbloc.2026.1784449
A multimodal vision dataset for nursing action recognition and quality assessment in NICU
Zhou, R., Tang, X. Y., Zhao, L., Shen, J., Sha, S., Qin, Y., Xin, Y., Guo, W., & Qian, J. (2026) · Scientific Data · doi:10.1038/s41597-026-07533-4
Momose, K., Shiina, T., Takemoto, Y., Okada, M., Koide, K., Yokoi, T., Sugimoto, A., Kanie, K., Tanaka, K., & Kato, R. (2026) · Regenerative Therapy · doi:10.1016/j.reth.2026.101178
Metadata
- Authors
- Ma, A. J., Rawat, N., Reiter, A., Shrock, C., Zhan, A., Stone, A., Rabiee, A., Griffin, S., Needham, D. M., & Saria, S.
- Affiliations
- Johns Hopkins University (US)
- Johns Hopkins Hospital (US)
- Venue
- Critical Care Medicine
- Published
- 2017-04
- Volume
- 45
- Issue
- 4
- Pages
- 630-636
- ISSN
- 0090-3493 (ISSN-L)
- PMC
- PMC5697716
- OpenAlex
- W2597334832
- Semantic Scholar
- aa2c50398344887acb9775b16d25e46616947541
- Cited by
- 53
- References
- 30
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 2 · 2023: 5 · 2022: 9 · 2021: 7 · 2020: 7 · 2019: 9 · 2018: 6 · 2017: 1
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Gordon and Betty Moore Foundation
- National Heart, Lung, and Blood Institute (K23HL125982)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Intensive Care Unit Cognitive Disorders
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- patient mobility, intensive care unit, Kinect sensor, depth imaging, walking, sensor validation
- MeSH terms
- Aged, Algorithms, Female, Humans, Intensive Care Units, Male, Middle Aged, Monitoring, Physiologic, Movement, Prospective Studies, Video Recording, Walking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.