The Confusion Assessment Method for the ICU-7 Delirium Severity Scale: A Novel Delirium Severity Instrument for Use in the ICU

Open access
Khan, Babar A., Perkins, Anthony J., Gao, Sujuan, Hui, Siu L., Campbell, Noll L., Farber, Mark O., Chlan, Linda L., Boustani, Malaz A.·2017·Critical Care Medicine

Abstract

Objectives: Delirium severity is independently associated with longer hospital stays, nursing home placement, and death in patients outside the ICU. Delirium severity in the ICU is not routinely measured because the available instruments are difficult to complete in critically ill patients. We designed our study to assess the reliability and validity of a new ICU delirium severity tool, the Confusion Assessment Method for the ICU-7 delirium severity scale. Design: Observational cohort study. Setting: Medical, surgical, and progressive ICUs of three academic hospitals. Patients: Five hundred eighteen adult (≥ 18 yr) patients. Interventions: None. Measurements and Main Results: Patients received the Confusion Assessment Method for the ICU, Richmond Agitation-Sedation Scale, and Delirium Rating Scale-Revised-98 assessments. A 7-point scale (0–7) was derived from responses to the Confusion Assessment Method for the ICU and Richmond Agitation-Sedation Scale items. Confusion Assessment Method for the ICU-7 showed high internal consistency (Cronbach’s α = 0.85) and good correlation with Delirium Rating Scale-Revised-98 scores (correlation coefficient = 0.64). Known-groups validity was supported by the separation of mechanically ventilated and nonventilated assessments. Median Confusion Assessment Method for the ICU-7 scores demonstrated good predictive validity with higher odds (odds ratio = 1.47; 95% CI = 1.30–1.66) of in-hospital mortality and lower odds (odds ratio = 0.8; 95% CI = 0.72–0.9) of being discharged home after adjusting for age, race, gender, severity of illness, and chronic comorbidities. Higher Confusion Assessment Method for the ICU-7 scores were also associated with increased length of ICU stay (p = 0.001). Conclusions: Our results suggest that Confusion Assessment Method for the ICU-7 is a valid and reliable delirium severity measure among ICU patients. Further research comparing it to other delirium severity measures, its use in delirium efficacy trials, and real-life implementation is needed to determine its role in research and clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000002368

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 231

Metadata

Authors
Khan, B. A., Perkins, A. J., Gao, S., Hui, S. L., Campbell, N. L., Farber, M. O., Chlan, L. L., & Boustani, M. A.
Venue
Critical Care Medicine
Published
2017-05
Volume
45
Issue
5
Pages
851-857
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2592573234
Cited by
231
References
4
FWCI
16.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Confusion Assessment Method for the ICU-7 Delirium Severity Scale: A Novel Delirium Severity Instrument for Use in the ICU. https://app.cochat.ai/papers/10.1097/ccm.0000000000002368
The paper
Khan, B. A., Perkins, A. J., Gao, S., Hui, S. L., Campbell, N. L., Farber, M. O., Chlan, L. L., & Boustani, M. A. (2017). The Confusion Assessment Method for the ICU-7 Delirium Severity Scale: A Novel Delirium Severity Instrument for Use in the ICU. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000002368

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.