CoChat

The Association Between Ventilator Dyssynchrony, Delivered Tidal Volume, and Sedation Using a Novel Automated Ventilator Dyssynchrony Detection Algorithm*

Open access
Sottile, Peter D., Albers, David, Higgins, Carrie, Mckeehan, Jeffery, Moss, Marc M. · 2018 · Critical Care Medicine
Cited by 111

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: Ventilator dyssynchrony is potentially harmful to patients with or at risk for the acute respiratory distress syndrome. Automated detection of ventilator dyssynchrony from ventilator waveforms has been difficult. It is unclear if certain types of ventilator dyssynchrony deliver large tidal volumes and whether levels of sedation alter the frequency of ventilator dyssynchrony. Design: A prospective observational study. Setting: A university medical ICU. Patients: Patients with or at risk for acute respiratory distress syndrome. Interventions: Continuous pressure-time, flow-time, and volume-time data were directly obtained from the ventilator. The level of sedation and the use of neuromuscular blockade was extracted from the medical record. Machine learning algorithms that incorporate clinical insight were developed and trained to detect four previously described and clinically relevant forms of ventilator dyssynchrony. The association between normalized tidal volume and ventilator dyssynchrony and the association between sedation and the frequency of ventilator dyssynchrony were determined. Measurements and Main Results: A total of 4.26 million breaths were recorded from 62 ventilated patients. Our algorithm detected three types of ventilator dyssynchrony with an area under the receiver operator curve of greater than 0.89. Ventilator dyssynchrony occurred in 34.4% (95% CI, 34.41–34.49%) of breaths. When compared with synchronous breaths, double-triggered and flow-limited breaths were more likely to deliver tidal volumes greater than 10 mL/kg (40% and 11% compared with 0.2%; p < 0.001 for both comparisons). Deep sedation reduced but did not eliminate the frequency of all ventilator dyssynchrony breaths (p < 0.05). Ventilator dyssynchrony was eliminated with neuromuscular blockade (p < 0.001). Conclusion: We developed a computerized algorithm that accurately detects three types of ventilator dyssynchrony. Double-triggered and flow-limited breaths are associated with the frequent delivery of tidal volumes of greater than 10 mL/kg. Although ventilator dyssynchrony is reduced by deep sedation, potentially deleterious tidal volumes may still be delivered. However, neuromuscular blockade effectively eliminates ventilator dyssynchrony.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000002849

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 111

Metadata

Authors
Sottile, P. D., Albers, D., Higgins, C., Mckeehan, J., & Moss, M. M.
Venue
Critical Care Medicine
Published
2018-02
Volume
46
Issue
2
Pages
e151-e157
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2791905413
Cited by
111
References
2
FWCI
8.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Association Between Ventilator Dyssynchrony, Delivered Tidal Volume, and Sedation Using a Novel Automated Ventilator Dyssynchrony Detection Algorithm*. https://app.cochat.ai/papers/10.1097/ccm.0000000000002849
The paper
Sottile, P. D., Albers, D., Higgins, C., Mckeehan, J., & Moss, M. M. (2018). The Association Between Ventilator Dyssynchrony, Delivered Tidal Volume, and Sedation Using a Novel Automated Ventilator Dyssynchrony Detection Algorithm*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000002849

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.