Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A randomized trial of protocol-directed sedation management for mechanical ventilation in an Australian intensive care unit*

Bucknall, Tracey K., Manias, Elizabeth, Presneill, Jeffrey J.·2008·Critical Care Medicine

Abstract

OBJECTIVE: To compare protocol-directed sedation management with traditional non-protocol-directed practice in mechanically ventilated patients. DESIGN: Randomized, controlled trial. SETTING: General intensive care unit (24 beds) in an Australian metropolitan teaching hospital. PATIENTS: Adult, mechanically ventilated patients (n = 312). INTERVENTIONS: Patients were randomly assigned to receive sedation directed by formal guidelines (protocol group, n = 153) or usual local clinical practice (control, n = 159). MEASUREMENTS AND MAIN RESULTS: The median (95% confidence interval) duration of ventilation was 79 hrs (56-93 hrs) for patients in the protocol group compared with 58 hrs (44-78 hrs) for patients who received control care (p = .20). Lengths of stay (median [range]) in the intensive care unit (94 [2-1106] hrs vs. 88 (14-962) hrs, p = .58) and hospital (13 [1-113] days vs. 13 (1-365) days, p = .97) were similar, as were the proportions of subjects receiving a tracheostomy (17% vs. 15%, p = .64) or undergoing unplanned self-extubation (1.3% vs. 0.6%, p = .61). Death in the intensive care unit occurred in 32 (21%) patients in the protocol group and 32 (20%) control subjects (p = .89), with a similar overall proportion of deaths in hospital (25% vs. 22%, p = .51). A Cox proportional hazards model, after adjustment for age, gender, Acute Physiology and Chronic Health Evaluation II score, diagnostic category, and doses of commonly used drugs, estimated that protocol sedation management was associated with a 22% decrease (95% confidence interval 40% decrease to 2% increase, p = .07) in the occurrence of successful weaning from mechanical ventilation. CONCLUSIONS: This randomized trial provided no evidence of a substantial reduction in the duration of mechanical ventilation or length of stay, in either the intensive care unit or the hospital, with the use of protocol-directed sedation compared with usual local management. Qualified high-intensity nurse staffing and routine Australian intensive care unit nursing responsibility for many aspects of ventilatory practice may explain the contrast between these findings and some recent North American studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318168f82d

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 188

Metadata

Authors
Bucknall, T. K., Manias, E., & Presneill, J. J.
Venue
Critical Care Medicine
Published
2008-05
Volume
36
Issue
5
Pages
1444-1450
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1995955106
Cited by
188
References
3
FWCI
11.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A randomized trial of protocol-directed sedation management for mechanical ventilation in an Australian intensive care unit*. https://app.cochat.ai/papers/10.1097/ccm.0b013e318168f82d
The paper
Bucknall, T. K., Manias, E., & Presneill, J. J. (2008). A randomized trial of protocol-directed sedation management for mechanical ventilation in an Australian intensive care unit*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318168f82d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.