Validation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients*

Savard, Jean-François, Faisy, Christophe, Lerolle, Nicolas, Guerot, Emmanuel, Diehl, Jean-Luc, Fagon, Jean-Yves · 2008 · Critical Care Medicine
Cited by 53

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Use comparison with indirect calorimetry to confirm the ability of our previously described equation to predict resting energy expenditure in mechanically ventilated patients. DESIGN: Prospective, validation study. SETTING: Eighteen-bed, medical intensive care unit at a teaching hospital. PATIENTS: All adult patients intubated >24 hrs were assessed for eligibility. Exclusion criteria were clinical situations that could contribute to erroneous calorimetric measurements. INTERVENTIONS: Resting energy expenditure was calculated using the original Harris-Benedict equations and those corrected for usual stress factors, the Swinamer equation, the Fusco equation, the Ireton-Jones equation, and our equation: resting energy expenditure (kcal/day) = 8 x weight (kg) + 14 x height (cm) + 32 x minute ventilation (L/min) + 94 x temperature (degrees C) - 4834. MEASUREMENTS AND MAIN RESULTS: Resting energy expenditure was measured by indirect calorimetry for the 45 included patients. Resting energy expenditure calculated with our predictive model correlated with the measured resting energy expenditure (r2 = .62, p < .0001), and Bland-Altman analysis showed a mean bias of -192 +/- 277 kcal/day, with limits of agreement ranging from -735 to 351 kcal/day. Resting energy expenditure calculated with the Harris-Benedict equations was more weakly correlated with measured resting energy expenditure (r2 = .41, p < .0001), with Bland-Altman analysis showing a mean bias of 279 +/- 346 kcal/day between them and the limits of agreement ranging from -399 to 957 kcal/day. Applying usual stress-correction factors to the Harris-Benedict equations generated wide variability, and the correlation with measured resting energy expenditure was poorer (r2 = .18, p < .0001), with Bland-Altman analysis showing a mean bias of -357 +/- 750 kcal/day and limits of agreement ranging from -1827 to 1113 kcal/day. The use of the Swinamer, Fusco, or Ireton-Jones predictive methods yielded weaker correlation between calculated and measured resting energy expenditure (r2 = .41, p < .0001; r2 = .38, p < .0001; r2 = .39, p < .0001, respectively) than our equation, and Bland-Altman analysis showed no improvement in agreement and variability between methods. CONCLUSIONS: The Faisy equation, based on static (height), less stable (weight), and dynamic biometric variables (temperature and minute ventilation), provided precise and unbiased resting energy expenditure estimations in mechanically ventilated patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181691502

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 53

Metadata

Authors
Savard, J.-F., Faisy, C., Lerolle, N., Guerot, E., Diehl, J.-L., & Fagon, J.-Y.
Venue
Critical Care Medicine
Published
2008-04
Volume
36
Issue
4
Pages
1175-1183
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2029844498
Cited by
53
References
1
FWCI
3.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181691502
The paper
Savard, J.-F., Faisy, C., Lerolle, N., Guerot, E., Diehl, J.-L., & Fagon, J.-Y. (2008). Validation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181691502

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.