Real-time detection of pneumothorax using electrical impedance tomography*
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. DESIGN: Prospective controlled laboratory animal investigation. SETTING: Experimental Pulmonology Laboratory of the University of São Paulo. SUBJECTS: Thirty-nine anesthetized mechanically ventilated supine pigs (31.0 +/- 3.2 kg, mean +/- SD). INTERVENTIONS: In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 to 500 mL) through chest tubes or applied large positive end-expiratory pressure (PEEP) increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or preinjured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. MEASUREMENTS AND MAIN RESULTS: Primary EIT relative images were acquired online (50 images/sec) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20 mL could be detected with a sensitivity of 100% and specificity 95% and could be easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers. Their location was correctly identified in all cases, with a total delay of only three respiratory cycles. CONCLUSIONS: We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Self-citationComplications and Failures of Subclavian-Vein Catheterization
Mansfield, P. F., Hohn, D. C., Fornage, B. D., Gregurich, M. A., & Ota, D. M. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412293312602 · Cited by 713
Complications and Failures of Subclavian-Vein Catheterization
(1995) · New England Journal of Medicine · doi:10.1056/nejm199506083322313 · Cited by 626
Reversibility of Lung Collapse and Hypoxemia in Early Acute Respiratory Distress Syndrome
Borges, J. B., Okamoto, V. N., Matos, G. F. J., Caramez, M. P. R., Arantes, P. R., Barros, F., Souza, C. E., Victorino, J. A., Kacmarek, R. M., Barbas, C. S. V., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200506-976oc · Cited by 516
Self-citationWeg, J. G., Anzueto, A., Balk, R. A., Wiedemann, H. P., Pattishall, E. N., Schork, M. A., & Wagner, L. A. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380601 · Cited by 198
Caramez, M. P., Borges, J. B., Tucci, M. R., Okamoto, V. N., de Carvalho, C. R. R., Kacmarek, R. M., Malhotra, A., Velasco, I. T., & Amato, M. B. P. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000168044.98844.30 · Cited by 145
Self-citationBarbas, C. S. V., de Matos, G. F. J., Pincelli, M. P., Borges, E. D. R., Antunes, T., de Barros, J. M., Okamoto, V. N., Borges, J. B., Amato, M. B. P., & de Carvalho, C. R. R. (2005) · Current Opinion in Critical Care · doi:10.1097/00075198-200502000-00004 · Cited by 130
Self-citationWolf, G. K., & Arnold, J. H. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155917.39056.97 · Cited by 108 · cited 1×
“It has been shown that EIT images correlate well with regional ventilation within the thorax (11, 12).”
BackgroundPneumothorax in the Intensive Care Unit
de Lassence, A., Timsit, J., Tafflet, M., Azoulay, É., Jamali, S., Vincent, F., Cohen, Y., Garrouste-Orgeas, M., Alberti, C., & Dreyfuss, D. (2005) · Anesthesiology · doi:10.1097/00000542-200601000-00003 · Cited by 98 · cited 2×
“The placement of central venous catheters carries an important risk of developing a pneumothorax (4, 23).”
BackgroundImaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT
Hahn, G., Just, A., Dudykevych, T., et al. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/5/s16 · Cited by 97 · cited 1×
“One previous investigation suggested that the use of an absolute image generation algorithm, which is able to perceive the presence of air in the pleural space without the need for a baseline image (22), might be more appropriate.”
Background
Cited by
Corley, A., Caruana, L. R., Barnett, A. G., Tronstad, O., & Fraser, J. F. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer265 · Cited by 496
Zhao, Z., Möller, K., Steinmann, D., Frerichs, I., & Guttmann, J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1589-y · Cited by 321
Electrical impedance tomography in acute respiratory distress syndrome
Bachmann, M. C., Morais, C., Bugedo, G., Bruhn, A., Morales, A., Borges, J. B., Costa, E., & Retamal, J. (2018) · Critical Care · doi:10.1186/s13054-018-2195-6 · Cited by 204
Self-citationElectrical impedance tomography
Costa, E. L., Lima, R. G., & Amato, M. B. (2009) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3283220e8c · Cited by 189
Self-citation
Metadata
- Authors
- Costa, E. L. V., Chaves, C. N., Gomes, S., Beraldo, M. A., Volpe, M. S., Tucci, M. R., Schettino, I. A. L., Bohm, S. H., Carvalho, C. R. R., Tanaka, H., Lima, R. G., & Amato, M. B. P.
- Venue
- Critical Care Medicine
- Published
- 2008-04
- Volume
- 36
- Issue
- 4
- Pages
- 1230-1238
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2012087504
- Cited by
- 188
- References
- 12
- FWCI
- 9.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.