Impact of continuous venovenous hemofiltration on organ failure during the early phase of severe sepsis: A randomized controlled trial*

Payen, Didier, Mateo, Joaquim, Cavaillon, Jean Marc, Fraisse, François, Floriot, Christian, Vicaut, Eric·2009·Critical Care Medicine

Abstract

OBJECTIVE: The impact of continuous venovenous hemofiltration on sepsis-induced multiple organ failure severity is controversial. We sought to assess the effect of early application of hemofiltration on the degree of organ dysfunction and plasma cytokine levels in patients with severe sepsis or septic shock. DESIGN: Prospective, randomized, open, multicenter study setting, 12 French intensive care units. PATIENTS: A total of 80 patients were enrolled within 24 hours of development of the first organ failure related to a new septic insult. INTERVENTIONS: Patients were randomized to group 1 (HF), who received hemofiltration (25 mL/kg/hr) for a 96-hour period, or group 2 (C) who were managed conventionally. MEASUREMENTS AND MAIN RESULTS: The primary end point was the number, severity, and duration of organ failures during 14 days, as evaluated by the Sepsis-Related Organ Failure Assessment score, on an intention-to-treat analysis. Strict guidelines were provided to perform continuous hemofiltration under the same conditions and bearing the same objectives in all centers. Because of inclusion stagnation, the trial was discontinued after an interim analysis by which time 76 patients had been randomized. The number and severity of organ failures were significantly higher in the HF group (p < 0.05). No modifications in plasma cytokine levels could be detected. CONCLUSION: These data suggest that early application of standard continuous venovenous hemofiltration is deleterious in severe sepsis and septic shock. This study does not rule out an effect of high-volume hemofiltration (>35 mL/kg/hr) on the course of sepsis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181962316

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 298

Metadata

Authors
Payen, D., Mateo, J., Cavaillon, J. M., Fraisse, F., Floriot, C., & Vicaut, E.
Venue
Critical Care Medicine
Published
2009-03
Volume
37
Issue
3
Pages
803-810
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2117414166
Cited by
298
References
20
FWCI
17.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of continuous venovenous hemofiltration on organ failure during the early phase of severe sepsis: A randomized controlled trial*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181962316
The paper
Payen, D., Mateo, J., Cavaillon, J. M., Fraisse, F., Floriot, C., & Vicaut, E. (2009). Impact of continuous venovenous hemofiltration on organ failure during the early phase of severe sepsis: A randomized controlled trial*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181962316

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.