The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Crystalloid or colloid fluid loading and pulmonary permeability, edema, and injury in septic and nonseptic critically ill patients with hypovolemia*
Abstract
OBJECTIVE: To compare crystalloid and colloid fluids in their effect on pulmonary edema in hypovolemic septic and nonseptic patients with or at risk for acute lung injury/acute respiratory distress syndrome. We hypothesized that 1) crystalloid loading results in more edema formation than colloid loading and 2) the differences among the types of fluid decreases at high permeability. DESIGN, SETTING, AND PATIENTS: Prospective randomized clinical trial on the effect of fluids in 24 septic and 24 nonseptic mechanically ventilated patients with clinical hypovolemia. INTERVENTIONS: Patients were assigned to NaCl 0.9%, gelatin 4%, hydroxyethyl starch 6%, or albumin 5% loading for 90 minutes according to changes in filling pressures. MEASUREMENTS AND MAIN RESULTS: Twenty-three septic and 10 nonseptic patients had acute lung injury/acute respiratory distress syndrome (p < 0.001). Septic patients had greater pulmonary capillary permeability, edema, and severity of lung injury than nonseptic patients (p < 0.01), as measured by the pulmonary leak index (PLI) for Gallium-labeled transferrin, extravascular lung water (EVLW), and lung injury score (LIS), respectively. Colloids increased plasma volume, cardiac index, and central venous pressure (CVP) more than crystalloids (p < 0.05), although more crystalloids were infused (p < 0.05). Colloid osmotic pressure (COP) increased in colloid and decreased in crystalloid groups (p < 0.001). Irrespective of fluid type or underlying disease, the pulmonary leak index increased by median 5% (p < 0.05). Regardless of fluid type or underlying disease, EVLW and LIS did not change during fluid loading and EVLW related to COP-CVP (rs = -.40, p < 0.01). CONCLUSIONS: Pulmonary edema and LIS are not affected by the type of fluid loading in the steep part of the cardiac function curve in both septic and nonseptic patients. Then, pulmonary capillary permeability may be a smaller determinant of pulmonary edema than COP and CVP. Safety factors may have prevented edema during a small filtration pressure-induced rise in pulmonary protein and thus fluid transport.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Acute Respiratory Distress Syndrome
Ware, L. B., & Matthay, M. A. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421806 · Cited by 4,666
Cited by
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Colloids versus crystalloids for fluid resuscitation in critically ill patients
Perel, P., Roberts, I., & Ker, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000567.pub6 · Cited by 1,115
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Woodcock, T. E., & Woodcock, T. M. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer515 · Cited by 806
Zarychanski, R., Abou-Setta, A. M., Turgeon, A. F., Houston, B. L., McIntyre, L., Marshall, J. C., & Fergusson, D. A. (2013) · JAMA · doi:10.1001/jama.2013.430 · Cited by 649
Metadata
- Authors
- van der Heijden, M., Verheij, J., van Nieuw Amerongen, G. P., & Groeneveld, A. B. J.
- Venue
- Critical Care Medicine
- Published
- 2009-04
- Volume
- 37
- Issue
- 4
- Pages
- 1275-1281
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2063510188
- Cited by
- 166
- References
- 1
- FWCI
- 16.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.