Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Echocardiographic diagnosis of pulmonary artery occlusion pressure elevation during weaning from mechanical ventilation*

Lamia, Bouchra, Maizel, Julien, Ochagavia, Ana, Chemla, Denis, Osman, David, Richard, Christian, Teboul, Jean-Louis · 2009 · Critical Care Medicine

Abstract

OBJECTIVE: Weaning-induced pulmonary edema is a cause of weaning failure in high-risk patients. The diagnosis may require pulmonary artery catheterization to demonstrate increased pulmonary artery occlusion pressure (PAOP) during weaning. Transthoracic echocardiography can estimate left ventricular filling pressures using early (E) and late (A) peak diastolic velocities measured with Doppler transmitral flow, and tissue Doppler imaging of mitral annulus velocities including early (Ea) peak diastolic velocity. We tested the hypothesis that E/A and E/Ea could be used to detect weaning-induced PAOP elevation defined by a PAOP > or =18 mm Hg during a spontaneous breathing trial (SBT). MEASUREMENTS AND MAIN RESULTS: We included 39 patients who previously failed two consecutive SBTs. A third SBT was performed over a maximum 1-hour period using a T-piece. The PAOP, E/A, and E/Ea were measured before and during this SBT. Receiver operating characteristic curves were constructed to determine the optimal sensitivity and specificity values of E/A and E/Ea obtained at the end of the SBT for predicting a weaning-induced PAOP elevation. Weaning-induced PAOP elevation occurred in 17 patients. A value of E/A >0.95 at the end of the SBT predicted weaning-induced PAOP elevation with a sensitivity of 88% and a specificity of 68%. A value of E/Ea >8.5 at the end of the SBT predicted weaning-induced PAOP elevation with a sensitivity of 94% and a specificity of 73%. The combination of E/A >0.95 and E/Ea >8.5 predicted a weaning-induced PAOP elevation with a sensitivity of 82% and a specificity of 91%. CONCLUSION: At the end of an SBT, the combination of E/A >0.95 and E/Ea >8.5 measured with transthoracic echocardiography allowed an accurate noninvasive detection of weaning-induced PAOP elevation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e31819f13d0

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 178

Metadata

Authors
Lamia, B., Maizel, J., Ochagavia, A., Chemla, D., Osman, D., Richard, C., & Teboul, J.-L.
Venue
Critical Care Medicine
Published
2009-05
Volume
37
Issue
5
Pages
1696-1701
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1987235237
Cited by
178
References
2
FWCI
11.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.