The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
The Decision to Extubate in the Intensive Care Unit
Abstract
The day of extubation is a critical time during an intensive care unit (ICU) stay. Extubation is usually decided after a weaning readiness test involving spontaneous breathing on a T-piece or low levels of ventilatory assist. Extubation failure occurs in 10 to 20% of patients and is associated with extremely poor outcomes, including high mortality rates of 25 to 50%. There is some evidence that extubation failure can directly worsen patient outcomes independently of underlying illness severity. Understanding the pathophysiology of weaning tests is essential given their central role in extubation decisions, yet few studies have investigated this point. Because extubation failure is relatively uncommon, randomized controlled trials on weaning are underpowered to address this issue. Moreover, most studies evaluated patients at low risk for extubation failure, whose reintubation rates were about 10 to 15%, whereas several studies identified high-risk patients with extubation failure rates exceeding 25 or 30%. Strategies for identifying patients at high risk for extubation failure are essential to improve the management of weaning and extubation. Two preventive measures may prove beneficial, although their exact role needs confirmation: one is noninvasive ventilation after extubation in high-risk or hypercapnic patients, and the other is steroid administration several hours before extubation. These measures might help to prevent postextubation respiratory distress in selected patient subgroups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delirium as a Predictor of Mortality in Mechanically Ventilated Patients in the Intensive Care Unit
Ely, E. W. (2004) · JAMA · doi:10.1001/jama.291.14.1753 · Cited by 3,073
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Girard, T. D., Kress, J. P., Fuchs, B. D., Thomason, J. W., Schweickert, W. D., Pun, B. T., Taichman, D. B., Dunn, J. G., Pohlman, A. S., Kinniry, P. A., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60105-1 · Cited by 2,055
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Paresis Acquired in the Intensive Care Unit<SUBTITLE>A Prospective Multicenter Study</SUBTITLE>
De Jonghe, B. (2002) · JAMA · doi:10.1001/jama.288.22.2859 · Cited by 1,516
Ely, E. W., Baker, A. M., Dunagan, D. P., Burke, H. L., Smith, A. C., Kelly, P. T., Johnson, M. M., Browder, R. W., Bowton, D. L., & Haponik, E. F. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352502 · Cited by 1,346
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Self-citationEsley, E. W., Ly, E., Aker, M., Unagan, D. O. P. D., Urke, L. B., Mith, C. S., Atrick, P., Elly, T. K., Argaret, M., Ohnson, M. J., et al. (1996) · Cited by 950
Noninvasive Positive-Pressure Ventilation for Respiratory Failure after Extubation
Esteban, A., Frutos-Vivar, F., Ferguson, N. D., Arabi, Y., Apezteguía, C., González, M., Epstein, S. K., Hill, N. S., Nava, S., Soares, M.-A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032736 · Cited by 894
Effect of Failed Extubation on the Outcome of Mechanical Ventilation
Epstein, S. K., Ciubotaru, R. L., & Wong, J. B. (1997) · Chest · doi:10.1378/chest.112.1.186 · Cited by 892
Cited by
COVID-19 Image Data Collection: Prospective Predictions are the Future
Cohen, J. P., Morrison, P., Dao, L., Roth, K., Duong, T., & Ghassem, M. (2020) · Machine Learning for Biomedical Imaging · doi:10.59275/j.melba.2020-48g7 · Cited by 927
Epidemiology of Weaning Outcome according to a New Definition. The WIND Study
Béduneau, G., Pham, T., Schortgen, F., Piquilloud, L., Zogheib, E., Jonas, M., Grelon, F., Runge, I., Terzi, N., Grangé, S., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0320oc · Cited by 599
Self-citationStéphan, F., Barrucand, B., Petit, P., Rézaiguia-Delclaux, S., Médard, A., Delannoy, B., Cosserant, B., Flicoteaux, G., Imbert, A., Pilorge, C., et al. (2015) · JAMA · doi:10.1001/jama.2015.5213 · Cited by 535
Pham, T., Heunks, L., Bellani, G., Madotto, F., Aragao, I., Beduneau, G., Goligher, E. C., Grasselli, G., Laake, J. H., Mancebo, J., et al. (2023) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(22)00449-0 · Cited by 282
Self-citationThille, A. W., Boissier, F., Ben Ghezala, H., Razazi, K., Mekontso-Dessap, A., & Brun-Buisson, C. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000000748 · Cited by 261
Self-citation
Metadata
- Authors
- Thille, A. W., Richard, J.-C. M., & Brochard, L.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-06-15
- Volume
- 187
- Issue
- 12
- Pages
- 1294-1302
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2041468256
- Cited by
- 576
- References
- 77
- FWCI
- 16.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Decision to Extubate in the Intensive Care Unit. https://app.cochat.ai/papers/10.1164/rccm.201208-1523ci
- The paper
- Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013). The Decision to Extubate in the Intensive Care Unit. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201208-1523ci
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.