The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Poor sleep quality is associated with late noninvasive ventilation failure in patients with acute hypercapnic respiratory failure*
Abstract
OBJECTIVE: To determine whether sleep quality helps to predict noninvasive ventilation outcome in patients with acute hypercapnic respiratory failure. Despite an initial clinical improvement, nearly one fourth of patients may fail noninvasive ventilation after several days. Because late intubation is associated with a poor prognosis, it may be useful to identify factors that may predict or explain late noninvasive ventilation failure. PATIENTS: We prospectively studied 27 hypercapnic patients in a medical intensive care unit who required noninvasive ventilation for >48 hrs. INTERVENTIONS: A 17-hr sleep polysomnography (3 PM-8 AM) was recorded 2 days to 4 days after noninvasive ventilation initiation. Late noninvasive ventilation failure was defined as death, endotracheal intubation, or persistent need for noninvasive ventilation on day 6. MEASUREMENTS AND MAIN RESULTS: An abnormal electroencephalographic pattern that eluded analysis by standard sleep-scoring criteria was noted in seven (50%) of the 14 patients with late noninvasive ventilation failure compared with one (8%) of the 13 patients successfully treated with noninvasive ventilation (p = .03). No clinical or laboratory variables explained the electroencephalographic differences. Patients failing noninvasive ventilation had poorer sleep quality with greater circadian sleep-cycle disruption and less nocturnal rapid eye movement sleep (6 mins [range, 0-12] vs. 26 mins [range, 6-49], p = .03), compared with patients successfully treated with noninvasive ventilation. Noninvasive ventilation failure was associated with delirium during the intensive care unit stay (64% vs. 0%). CONCLUSIONS: Late noninvasive ventilation failure in elderly patients with acute hypercapnic respiratory failure was associated with early sleep disturbances including an abnormal electroencephalographic pattern, disruption of the circadian sleep cycle, and decreased rapid eye movement sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
Ely, E. W., Inouye, S. K., Bernard, G. R., Gordon, S., Francis, J., May, L., Truman, B., Speroff, T., Gautam, S., Margolin, R., et al. (2001) · JAMA · doi:10.1001/jama.286.21.2703 · Cited by 3,210
Delirium as a Predictor of Mortality in Mechanically Ventilated Patients in the Intensive Care Unit
Ely, E. W. (2004) · JAMA · doi:10.1001/jama.291.14.1753 · Cited by 3,073
The cognitive neuroscience of sleep: neuronal systems, consciousness and learning
Hobson, J. A., & Pace-Schott, E. F. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn915 · Cited by 835
Cited by
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Self-citationBTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults
Davidson, A. C., Banham, S., Elliott, M., Kennedy, D., Gelder, C., Glossop, A., Church, A. C., Creagh-Brown, B., Dodd, J. W., Felton, T., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-208209 · Cited by 426
Mantz, J., Josserand, J., & Hamada, S. (2011) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32833e266d · Cited by 272
Timing of noninvasive ventilation failure: causes, risk factors, and potential remedies
Ozyilmaz, E., Ugurlu, A. O., & Nava, S. (2014) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-14-19 · Cited by 260
Metadata
- Authors
- Campo, F. R., Drouot, X., Thille, A. W., Galia, F., Cabello, B., dʼOrtho, M.-P., & Brochard, L.
- Venue
- Critical Care Medicine
- Published
- 2010-02
- Volume
- 38
- Issue
- 2
- Pages
- 477-485
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2089921985
- Cited by
- 179
- References
- 5
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poor sleep quality is associated with late noninvasive ventilation failure in patients with acute hypercapnic respiratory failure*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181bc8243
- The paper
- Campo, F. R., Drouot, X., Thille, A. W., Galia, F., Cabello, B., dʼOrtho, M.-P., & Brochard, L. (2010). Poor sleep quality is associated with late noninvasive ventilation failure in patients with acute hypercapnic respiratory failure*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181bc8243
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.