The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hemodynamic impact of a positive end-expiratory pressure setting in acute respiratory distress syndrome: Importance of the volume status*
Abstract
OBJECTIVE: The hemodynamic impact of positive end-expiratory pressure in acute respiratory distress syndrome and the underlying mechanisms have not been extensively investigated during low stretch ventilation. Our aim was to evaluate the hemodynamic effect of increasing positive end-expiratory pressure when tidal volume and the plateau pressure are limited and to explore the underlying mechanisms. DESIGN: Prospective study. SETTING: Medical intensive care unit. PATIENTS: Twenty-one acute respiratory distress syndrome patients ventilated with a tidal volume of 6.0 +/- 0.5 mL/kg of predicted body weight. INTERVENTION: Positive end-expiratory pressure was significantly increased from 5 +/- 1 cm H2O to 13 +/- 4 cm H2O for reaching a plateau pressure of 30 +/- 1 cm H2O. At high positive end-expiratory pressure, passive leg raising was performed for increasing the central blood volume. MEASUREMENTS: We performed echocardiography and pulmonary artery catheterization during positive end-expiratory pressure increase and during passive leg raising at high positive end-expiratory pressure. MAIN RESULTS: With positive end-expiratory pressure elevation, the cardiac index decreased by 13% +/- 9%. The right ventricular end-diastolic area, right atrial pressure, and pulmonary vascular resistance increased by 13% +/- 20%, 34% +/- 24% and 32% +/- 31%, respectively (p < .01; p = .04; and p < .01 vs. baseline, respectively). The transpulmonary pressure difference (mean pulmonary artery pressure--pulmonary artery occlusion pressure) increased (p < .05). Both at low and high positive end-expiratory pressure, an acute cor pulmonale was observed in the same three (14%) patients. At high positive end-expiratory pressure, the passive leg raising significantly increased the right and left ventricular end-diastolic areas and right atrial pressure. Passive leg raising also decreased the transpulmonary pressure difference (p < .05), increased the cardiac index by 14% +/- 10%, and decreased the pulmonary vascular resistance by 21% +/- 20% (both p < .01 vs. baseline). CONCLUSIONS: In acute respiratory distress syndrome patients, a positive end-expiratory pressure increase with limited tidal volume and plateau pressure reduced cardiac output by increasing the right ventricular afterload. Passive leg raising restored cardiac output by reducing the transpulmonary pressure difference and the pulmonary vascular resistance. This suggests that some pulmonary microvessels were collapsed by positive end-expiratory pressure elevation and were recruited by increasing the central blood volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Comparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
Lung recruitment in patients with the acute respiratory distress syndrome.
Gattinoni, L., Caironi, P., Cressoni, M., Chiumello, D., Ranieri, V. M., Quintel, M., Russo, S., Patroniti, N., Cornejo, R., & Bugedo, G. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052052 · Cited by 1,548
Cited by
Clinical evidence does not support corticosteroid treatment for 2019-nCoV lung injury
Russell, C. D., Millar, J. E., & Baillie, J. K. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30317-2 · Cited by 2,008
Formal guidelines: Management of acute respiratory distress syndrome.
Papazian, L., Aubron, C., Brochard, L., Chiche, J.-D., Combes, A., Dreyfuss, D., Forel, J.-M., Guérin, C., Jaber, S., Mekontso-Dessap, A., et al. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0540-9 · Cited by 761
BTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults
Davidson, A. C., Banham, S., Elliott, M., Kennedy, D., Gelder, C., Glossop, A., Church, A. C., Creagh-Brown, B., Dodd, J. W., Felton, T., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-208209 · Cited by 426
Myocardial depression in sepsis: From pathogenesis to clinical manifestations and treatment
Antonucci, E., Fiaccadori, E., Donadello, K., Taccone, F. S., Franchi, F., & Scolletta, S. (2014) · Journal of Critical Care · doi:10.1016/j.jcrc.2014.03.028 · Cited by 307
Jozwiak, M., Silva, S., Persichini, R., Anguel, N., Osman, D., Richard, C., Teboul, J.-L., & Monnet, X. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31826ab377 · Cited by 259
Self-citation
Metadata
- Authors
- Fougères, E., Teboul, J.-L., Richard, C., Osman, D., Chemla, D., & Monnet, X.
- Venue
- Critical Care Medicine
- Published
- 2010-03
- Volume
- 38
- Issue
- 3
- Pages
- 802-807
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2039767293
- Cited by
- 176
- References
- 3
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.