A multifaceted program to prevent ventilator-associated pneumonia: Impact on compliance with preventive measures*
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the effect of a 2-yr multifaceted program aimed at preventing ventilator-acquired pneumonia on compliance with eight targeted preventive measures. DESIGN: Pre- and postintervention observational study. SETTING: A 20-bed medical intensive care unit in a teaching hospital. PATIENTS: A total of 1649 ventilator-days were observed. INTERVENTIONS: The program involved all healthcare workers and included a multidisciplinary task force, an educational session, direct observations with performance feedback, technical improvements, and reminders. It focused on eight targeted measures based on well-recognized published guidelines, easily and precisely defined acts, and directly concerned healthcare workers' bedside behavior. Compliance assessment consisted of five 4-wk periods (before the intervention and 1 month, 6 months, 12 months, and 24 months thereafter). MEASUREMENTS AND MAIN RESULTS: Hand-hygiene and glove-and-gown use compliances were initially high (68% and 80%) and remained stable over time. Compliance with all other preventive measures was initially low and increased steadily over time (before 2-yr level, p < .0001): backrest elevation (5% to 58%) and tracheal cuff pressure maintenance (40% to 89%), which improved after simple technical equipment implementation; orogastric tube use (52% to 96%); gastric overdistension avoidance (20% to 68%); good oral hygiene (47% to 90%); and nonessential tracheal suction elimination (41% to 92%). To assess overall performance of the last six preventive measures, using ventilator-days as the unit of analysis, a composite score for preventive measures applied (range, 0-6) was developed. The median (interquartile range) composite scores for the five successive assessments were 2 (1-3), 4 (3-5), 4 (4-5), 5 (4-6), and 5 (4-6) points; they increased significantly over time (p < .0001). Ventilator-acquired pneumonia prevalence rate decreased by 51% after intervention (p < .0001). CONCLUSIONS: Our active, long-lasting program for preventing ventilator-acquired pneumonia successfully increased compliance with preventive measures directly dependent on healthcare workers' bedside performance. The multidimensional framework was critical for this marked, progressive, and sustained change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Why Don't Physicians Follow Clinical Practice Guidelines?: A Framework for Improvement
Cabana, M. D., Rand, C. S., Powe, N. R., Wu, A. W., Wilson, M. H., Abboud, P.-A. C., & Rubin, H. R. (1999) · JAMA · doi:10.1001/jama.282.15.1458 · Cited by 6,677
An Intervention to Decrease Catheter-Related Bloodstream Infections in the ICU
Pronovost, P., Needham, D., Berenholtz, S., Sinopoli, D., Chu, H., Cosgrove, S., Sexton, B., Hyzy, R., Welsh, R., Roth, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061115 · Cited by 4,387
Effectiveness of a hospital-wide programme to improve compliance with hand hygiene
Pittet, D., Hugonnet, S., Harbarth, S., Mourouga, P., Sauvan, V., Touveneau, S., & Perneger, T. V. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02814-2 · Cited by 2,524
Guideline for hand hygiene in health-care settings
Boyce, J. M., & Pittet, D. (2002) · American Journal of Infection Control · doi:10.1067/mic.2002.130391 · Cited by 2,120
Drakulovic, M. B., Torres, A., Bauer, T. T., Nicolas, J. M., Nogué, S., & Ferrer, M. (1999) · The Lancet · doi:10.1016/s0140-6736(98)12251-1 · Cited by 1,243 · cited 1×
“Semirecumbency is an effective (30) and inexpensive VAP prevention measure.”
BackgroundTorres, A., Serra-Batlles, J., Ros, E., Piera, C., de la Bellacasa, J. P., Cobos, A., Lomeña, F., & Rodríguez-Roisin, R. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-7-540 · Cited by 721
Cited by
Physical interventions to interrupt or reduce the spread of respiratory viruses
Jefferson, T., Del Mar, C. B., Dooley, L., Ferroni, E., Al-Ansary, L. A., Bawazeer, G. A., van Driel, M. L., Nair, N. S., Jones, M. A., Thorning, S., et al. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006207.pub4 · Cited by 805
Economic Impact of Ventilator-Associated Pneumonia in a Large Matched Cohort
Kollef, M. H., Hamilton, C. W., & Ernst, F. R. (2012) · Infection Control & Hospital Epidemiology · doi:10.1086/664049 · Cited by 395
Physical interventions to interrupt or reduce the spread of respiratory viruses
Jefferson, T., Del Mar, C. B., Dooley, L., Ferroni, E., Al-Ansary, L. A., Bawazeer, G. A., van Driel, M. L., Jones, M. A., Thorning, S., Beller, E. M., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006207.pub5 · Cited by 318
Physical interventions to interrupt or reduce the spread of respiratory viruses
Jefferson, T., Dooley, L., Ferroni, E., Al-Ansary, L. A., van Driel, M. L., Bawazeer, G. A., Jones, M. A., Hoffmann, T. C., Clark, J., Beller, E. M., et al. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006207.pub6 · Cited by 291
Metadata
- Authors
- Bouadma, L., Mourvillier, B., Deiler, V., Le Corre, B., Lolom, I., Régnier, B., Wolff, M., & Lucet, J.-C.
- Venue
- Critical Care Medicine
- Published
- 2010-03
- Volume
- 38
- Issue
- 3
- Pages
- 789-796
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2025331047
- Cited by
- 151
- References
- 6
- FWCI
- 12.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multifaceted program to prevent ventilator-associated pneumonia: Impact on compliance with preventive measures*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181ce21af
- The paper
- Bouadma, L., Mourvillier, B., Deiler, V., Le Corre, B., Lolom, I., Régnier, B., Wolff, M., & Lucet, J.-C. (2010). A multifaceted program to prevent ventilator-associated pneumonia: Impact on compliance with preventive measures*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181ce21af
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.